ALF1T18

–1–
ASCTB195E 201606-T
ORDERING INFORMATION
TYPES
Standard packing: Carton 50 pcs., Case 200 pcs.
Load for air conditioner
1 Form A 20A power relays
LF RELAYS (ALF)
Contact arrangement Nominal coil voltage
Part No.
TMP type PCB type
1 Form A
5V DC ALF1T05 ALF1P05
6V DC ALF1T06 ALF1P06
9V DC ALF1T09 ALF1P09
12V DC ALF1T12 ALF1P12
18V DC ALF1T18 ALF1P18
24V DC ALF1T24 ALF1P24
Protective construction: Flux-resistant
type
TMP type PCB type
RoHS compliant
FEATURES
1. Ideal for compressor and inverter
loads
1) Compressor load: 20A 250V AC
2) Inverter load: 20A 100V AC,
10A 200V AC
2. Long insulation distance
• Creepage distance and clearances
between contact and coil;
Creepage Min. 9.5mm .374inch/
Clearance Min. 8mm .315inch
• Surge withstand voltage: 10,000V
3. “PCB” and “TMP” types available
4. Conforms to the various safety
standards:
UL/C-UL, TÜV and VDE approved
TYPICAL APPLICATIONS
1. Air conditioner
2. Refrigerators
3. OA equipment
LF relay
ALF 1
Terminal shape
T:
P:
TMP type
PCB type
Nominal coil voltage, V DC
05: 5, 06: 6, 09: 9, 12: 12, 18: 18, 24: 24
Contact arrangement
1: 1 Form A
Note: Certified by UL/C-UL,VDE and TÜV
LF (ALF)
–2–
ASCTB195E 201606-T
RATING
1. Coil data
2. Specifications
* Specifications will vary with foreign standards certification ratings.
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50μs according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
3. Switching capacity
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
(at 20°C 68°F)
Max. applied voltage
(at 20°C 68°F)
5V DC
70%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
180 mA 27.8Ω
900mW
110%V of
nominal voltage
6V DC 150 mA 40 Ω
9V DC 100 mA 90 Ω
12V DC 75 mA 160 Ω
18V DC 50 mA 360 Ω
24V DC 37.5mA 640 Ω
Characteristics Item Specifications
Contact
Arrangement 1 Form A
Contact resistance (Initial) Max. 100 mΩ (By voltage drop 6 V DC 1A)
Contact material AgSnO
2 type
Rating
Nominal switching capacity (resistive load) 20A 250V AC
Max. switching power (resistive load) 6,250VA
Max. switching voltage 250V AC
Max. switching current 25A
Nominal operating power 900mW
Min. switching capacity (reference value)*
1
100mA, 5V DC
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 1,000 Vrms for 1 min. (Detection current: 10 mA)
Between contact and coil 5,000 Vrms for 1 min. (Detection current: 10 mA)
Surge breakdown voltage*
2
(Between contact and coil) (Initial)
10,000 V
Operate time (at nominal voltage) (at 20°C 68°F)
(Initial)
Max. 20 ms (excluding contact bounce time.)
Release time (at nominal voltage) (at 20°C 68°F)
(Initial)
Max. 15 ms (excluding contact bounce time) (With diode)
Mechanical
characteristics
Shock resistance
Functional 100 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10μs.)
Destructive 1,000 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
Vibration resistance
Functional 10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10μs.)
Destructive 10 to 55 Hz at double amplitude of 1.5 mm
Expected life
Mechanical (at 180 times/min.) Min. 2×10
6
Electrical (at 20 times/min.) Min. 10
5
(resistive load)
Conditions
Conditions for operation, transport and storage*
3
Ambient temperature: –40°C to +60°C –40°F to +140°F,
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed 20 times/min. (at nominal switching capacity)
Unit weight Approx. 23 g .81 oz
Electrical Life
Resistive load
20 A, 250 V AC (cos
φ
= 1)
Min. 10
5
(at 20 times/min.)
25 A, 250 V AC (cos
φ
= 1)
Min. 10
4
(at 20 times/min.)
Compressor load
Inrush 70 A (cos
φ
= 0.7), Steady 20 A (cos
φ
= 0.9)
250 V AC
Min. 10
5
(at 20 times/min.)
Inverter load
Inrush 200 A, Steady 20 A
100 V AC
Min. 3×10
4
(at 10 times/min.)
Inrush 100 A, Steady 10 A
200 V AC
Min. 3×10
4
(at 10 times/min.)
LF (ALF)
–3–
ASCTB195E 201606-T
REFERENCE DATA
1. Coil temperature rise
Sample: ALF1T12, 6 pcs.
Point measured: coil inside
Ambient temperature: 25°C 77°F, 60°C 140°F
Contact current: 20A
2-(1). 200V AC electrical life test
(200V AC, inverter load)
Sample: ALF1T12, 6 pcs.
Load: Inrush 102A (wave peak value),
Steady 14.4A (wave peak value)
Inverter dummy 200V AC
Switching frequency: ON 1s, OFF 5s
Circuit:
Coil applied voltage, %V
80 100 120
70
60
50
40
30
20
10
0
60°C
25°C
Temperature rise, °C
158
140
122
104
86
68
50
32
°F
140°F
77°F
1.9Ω
LF relay contact
Switch
2,000μF
200V AC
063
0
2
4
6
8
10
12
Max.
Min.
x
Max.
Min.
x
Pick-up and drop-out voltage, V
No. of operations, ×10
4
Contact welding: 0 times
Miscontact: 0 times
Drop-out voltage
Pick-up voltage
2-(2). 100V AC electrical life test
(100V AC, inverter load)
Sample: ALF1T12, 6 pcs.
Load: Inrush 224A (wave peak value),
Steady 30.5A (wave peak value)
Inverter dummy 100V AC
Switching frequency: ON 1s, OFF 5s
Circuit:
LF relay contact
2,000μF
470μF
470μF
100V AC
063
0
2
4
6
8
10
12
Max.
Min.
x
Max.
Min.
x
Pick-up and drop-out voltage, V
No. of operations, ×10
4
Drop-out voltage
Pick-up voltage
Contact welding: 0 times
Miscontact: 0 times
2-(3). Inrush 70.7A, Steady 20A, 250V AC
electrical life test (Compressor dummy load)
Sample: ALF1T12, 6 pcs.
Load: Inrush 70.7A, cos
φ
= 0.7
Steady 20A, cos
φ
0.9
250V AC compressor dummy
Switching frequency: ON 1.5s, OFF 1.5s
Circuit:
2-(4). Electrical life test
(20A 250V AC, resistive load)
Sample: ALF1T12, 6 pcs.
Switching frequency: ON 1.5s, OFF 1.5s
SW1
NO
Mg
Detection
Circuit
Contact Weld
Min. 0.5s
Miss Contact
after 0.2s
COM
250V AC
60Hz
G
12V DC
(–)
(+)
0105
0
2
4
6
8
10
12
Max.
Min.
x
Max.
Min.
x
Pick-up and drop-out voltage, V
No. of operations, ×10
4
Drop-out voltage
Pick-up voltage
Contact welding: 0 times
Miscontact: 0 times
02010
0
2
4
6
8
10
Pick-up and drop-out voltage, V
No. of operations, ×10
4
12
Drop-out voltage
Pick-up voltage
Max.
Min.
x
Max.
Min.
x
Contact welding: 0 times
Miscontact: 0 times