MPX4100A
Rev 9, 1/2009
Freescale Semiconductor
© Freescale Semiconductor, Inc., 2005-2009. All rights reserved.
Pressure
+
Integrated Silicon Pressure Sensor
for Manifold Absolute Pressure
Applications On-Chip Signal
Conditioned, Temperature
Compensated and Calibrated
The MPX4100A series Manifold Absolute Pressure (MAP) sensor for
engine control is designed to sense absolute air pressure within the intake
manifold. This measurement can be used to compute the amount of fuel
required for each cylinder. The small form factor and high reliability of on-chip
integration makes the MAP sensor a logical and economical choice for
automotive system designers.
The MPX4100A series piezoresistive transducer is a state-of-the-art,
monolithic, signal conditioned, silicon pressure sensor. This sensor combines
advanced micromachining techniques, thin film metallization, and bipolar
semiconductor processing to provide an accurate, high level analog output
signal that is proportional to applied pressure.
Features
1.8% Maximum Error Over 0° to 85°C
Specifically Designed for Intake Manifold Absolute Pressure Sensing in Engine Control Systems
Ideally Suited for Microprocessor Interfacing or Microcontroller Based Systems
Temperature Compensated Over -40°C to +125°C
Durable Epoxy Unibody Element
Ideal for Non-Automotive Applications
Available as Standard Fluorosilicone Gel (MPXA4100A, MPX4100A) or Media Resistant Gel (MPXAZ4100A)
Durable Thermoplastic (PPS) Surface Mount Package
ORDERING INFORMATION
Device Name
Package
Options
Case
No.
# of Ports Pressure Type
Device Marking
None Single Dual Gauge Differential Absolute
Unibody Package (MPX4100A Series)
MPX4100A
Trays 867-08
MPX4100A
MPX4100AP
Trays 867B-04
MPX4100AP
MPX4100AS
Trays 867E-03
MPX4100AS
Small Outline Package (MPXAZ4100A Series) (Media Resistant Gel)
MPXAZ4100A6U
Rails 482
MPXAZ4100A
MPXAZ4100AC6U
Rails 482A
MPXAZ4100A
Small Outline Package (MPXA4100A Series)
MPXA4100A6T1
Tape and Reel 482
MPXA4100A
MPXA4100AC6U
Rails 482A
MPXA4100A
MPXA4100A6U
Rails 482
MPXA4100A
MPX4100A
20 to 105 kPa (2.9 to 15.2 psi)
0.3 to 4.9 V Output
Series
Application Examples
Manifold Sensing for Automotive
Systems
Also Ideal for Non-Automotive
Applications
MPX4100A
Sensors
2 Freescale Semiconductor
Pressure
MPX4100A
CASE 867-08
MPX4100AP
CASE 867B-04
MPX4100AS
CASE 867E-03
MPXAZ4100A6U
MPXA4100A6U/T1
CASE 482-01
MPXAZ4100AC6U
MPXA4100AC6U
CASE 482A-01
SMALL OUTLINE PACKAGES
UNIBODY PACKAGES
MPX4100A
Sensors
Freescale Semiconductor 3
Pressure
Operating Characteristics
Table 1. Operating Characteristics (V
S
= 5.1 Vdc, T
A
= 25°C unless otherwise noted, P1 > P2. Decoupling circuit shown in
Figure 3 required to meet electrical specifications.)
Characteristic Symbol Min Typ Max Unit
Pressure Range
(1)
1. 1.0 kPa (kiloPascal) equals 0.145 psi.
P
OP
20 105 kPa
Supply Voltage
(2)
2. Device is ratiometric within this specified excitation range.
V
S
4.85 5.1 5.35 Vdc
Supply Current
I
o
7.0 10 mAdc
Minimum Pressure Offset (0 to 85°C)
@ V
S
= 5.1 Volts
(3)
3. Offset (V
off
) is defined as the output voltage at the minimum rated pressure.
V
off
0.225 0.306 0.388 Vdc
Full Scale Output (0 to 85°C)
@ V
S
= 5.1 Volts
(4)
4. Full Scale Output (V
FSO
) is defined as the output voltage at the maximum or full rated pressure.
V
FSO
4.816 4.897 4.978 Vdc
Full Scale Span (0 to 85°C)
@ V
S
= 5.1 Volts
(5)
5. Full Scale Span (V
FSS
) is defined as the algebraic difference between the output voltage at full rated pressure and the output voltage at the
minimum rated pressure.
V
FSS
—4.59—Vdc
Accuracy
(6)
(0 to 85°C)
6. Accuracy (error budget) consists of the following:
Linearity: Output deviation from a straight line relationship with pressure over the specified pressure range.
Temperature Hysteresis: Output deviation at any temperature within the operating temperature range, after the temperature is cycled to
and from the minimum or maximum operating temperature points, with zero differential pressure applied.
Pressure Hysteresis: Output deviation at any pressure within the specified range, when this pressure is cycled to and from the
minimum or maximum rated pressure, at 25°C.
TcSpan: Output deviation over the temperature range of 0 to 85°C, relative to 25°C.
TcOffset: Output deviation with minimum rated pressure applied, over the temperature range of 0 to 85°C, relative to 25°C.
Variation from Nominal: The variation from nominal values, for Offset or Full Scale Span, as a percent of V
FSS
, at 25°C.
——±1.8 %V
FSS
Sensitivity
V/P 54 mV/kPa
Response Time
(7)
7. Response Time is defined as the time for the incremental change in the output to go from 10% to 90% of its final value when subjected to a
specified step change in pressure.
t
R
—1.0—ms
Output Source Current at Full Scale Output
I
o+
—0.1—mAdc
Warm-Up Time
(8)
8. Warm-up Time is defined as the time required for the product to meet the specified output voltage after the Pressure has been stabilized.
——20ms
Offset Stability
(9)
9. Offset Stability is the product's output deviation when subjected to 1000 hours of Pulsed Pressure, Temperature Cycling with Bias Test.
——±0.5 %V
FSS

MPX4100AP1

Mfr. #:
Manufacturer:
NXP / Freescale
Description:
Board Mount Pressure Sensors INTEG 15PSI 4V W/LDFORM
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: