MAX6675ISA+

AVAILABLE
Functional Diagrams
Pin Configurations appear at end of data sheet.
Functional Diagrams continued at end of data sheet.
UCSP is a trademark of Maxim Integrated Products, Inc.
For pricing, delivery, and
ordering information, please contact Maxim Direct
at 1-888-629-4642, or visit Maxim’s website at www.maximintegrated.com.
General Description
The MAX6675 performs cold-junction compensation
and digitizes the signal from a type-K thermocouple.
The data is output in a 12-bit resolution, SPI™-compati-
ble, read-only format.
This converter resolves temperatures to 0.25°C, allows
readings as high as +1024°C, and exhibits thermocou-
ple accuracy of 8LSBs for temperatures ranging from
0°C to +700°C.
The MAX6675 is available in a small, 8-pin SO package.
Applications
Industrial
Appliances
HVAC
Automotive
Features
Direct Digital Conversion of Type -K
Thermocouple Output
Cold-Junction Compensation
Simple SPI-Compatible Serial Interface
12-Bit, 0.25°C Resolution
Open Thermocouple Detection
Cold-Junction-Compensated K-Thermocouple-
to-Digital Converter (0°C to +1024°C)
CS
SCKV
CC
1
2
8
7
N.C.
SOT-
T+
GND
SO
TOP VIEW
3
4
6
5
MAX6675
Pin Configuration
Vcc
GND
T+
T-
SO
SCK
CS
MICROCONTROLLER
68HC11A8
MISO
SCK
SSB
0.1µF
MAX6675
Typical Application Circuit
Ordering Information
SPI is a trademark of Motorola, Inc.
PART TEMP RANGE PIN-PACKAGE
MAX6675ISA -20°C to +85°C 8 SO
19-2235; Rev 1; 3/02
MAX6675
Cold-Junction-Compensated K-Thermocouple-
to-Digital Converter (0°C to +1024°C)
ABSOLUTE MAXIMUM RATINGS
ELECTRICAL CHARACTERISTICS
(V
CC
= +3.0V to +5.5V, T
A
= -20°C to +85°C, unless otherwise noted. Typical values specified at +25°C.) (Note 1)
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
Supply Voltage (V
CC
to GND) ................................ -0.3V to +6V
SO, SCK,
CS, T-, T+ to GND .......................-0.3V to V
CC
+ 0.3V
SO Current ........................................................................ 50mA
ESD Protection (Human Body Model) ........................... ±2000V
Continuous Power Dissipation (T
A
= +70°C)
8-Pin SO (derate 5.88mW/°C above +70°C) .............. 471mW
Operating Temperature Range ..........................-20°C to +85°C
Storage Temperature Range ............................-65°C to +150°C
Junction Temperature .................................................... +150°C
SO Package
Vapor Phase (60s) . .....................................................+215°C
Infrared (15s) ..............................................................+220°C
Lead Temperature (soldering, 10s) ............................... +300°C
SYMBOL
MIN
TYP
MAX
UNITS
T
THERMOCOUPLE
= +700°C,
+700°C, T
A
= +25°C (Note 2)
+17
+19
LSB
10.25
µV/LSB
-3.0 +3.0
-3.0 +3.0
0.25
0.17 0.22
V
CC
V
CC
MAX6675
2
Maxim Integrated
Cold-Junction-Compensated K-Thermocouple-
to-Digital Converter (0°C to +1024°C)
10
8
6
4
2
0
04515 30 60 75 90
OUTPUT CODE ERROR
vs. AMBIENT TEMPERATURE
MAX6675 toc01
TEMPERATURE (°C)
OUTPUT CODE ERROR (LSB)
-5
0
5
10
-10 0 30 50
OUTPUT CODE ERROR
vs. VOLTAGE DIFFERENTIAL
MAX6675 toc02
VOLTAGE DIFFERENTIAL (mV)
OUTPUT CODE ERROR (LSB)
10 20 40
Typical Operating Characteristics
(V
CC
= +3.3V, T
A
= +25°C, unless otherwise noted.)
ELECTRICAL CHARACTERISTICS (continued)
(V
CC
= +3.0V to +5.5V, T
A
= -20°C to +85°C, unless otherwise noted. Typical values specified at +25°C.) (Note 1)
Note 1: All specifications are 100% tested at T
A
= +25°C. Specification limits over temperature (T
A
= T
MIN
to T
MAX
) are guaranteed
by design and characterization, not production tested.
Note 2: Guaranteed by design. Not production tested.
SYMBOL
MIN TYP MAX
UNITS
MHz
100
100
100
MAX6675
Maxim Integrated
3

MAX6675ISA+

Mfr. #:
Manufacturer:
Maxim Integrated
Description:
Sensor Interface K Thermocouple to Digital Converter
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union