MP2607 – LI-ION CHARGER WITH POWER PATH MANAGEMENT
MP2607 Rev. 1.03 www.MonolithicPower.com 4
5/18/2015 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited.
© 2015 MPS. All Rights Reserved.
ELECTRICAL CHARACTERISTICS
(5)
(continued)
V
IN
= 5.5V, V
BATT
= 3.5V, V
CEB
= GND, T
A
= 25°C, unless otherwise noted.
Paramete
r
Symbol Condition Min Typ Max Units
Supply Current at Input I
IN
CEB
= GND, I
CHG
= 0A, I
SYS
= 0A,
V
BATT
=4.5V , V
IN
= 5.5V, MODE = 5V
420
µA
CEB
= GND, I
CHG
= 0A, I
SYS
= 0A,
V
BATT
=4.5V, V
IN
= 5.5V, MODE = GND
400
CEB
= 5V, I
CHG
= 0A, I
SYS
= 0A,
V
BATT
=4.5V, V
IN
= 5.5V
120 µA
CEB
= 5V, I
CHG
= 0A, I
SYS
= 0A,
V
BATT
=4.5V, V
IN
= 12V
1.4 mA
Supply Current at BATT
Input
I
BATT
CEB
= GND,
I
SYS
=0A
V
IN
=5.5V
,
V
BATT
=4.5V
125
µA
V
IN
= 4V, V
BATT
=4.5V
25 35
CEB
= 5V, I
SYS
= 0A, V
BATT
=3.5V
20 30
BATT Input to SYS Switch
On Resistance
R
ON_BSW
V
IN
=GND, V
BATT
=3.5V, I
SYS
=100mA 50 80 m
BATT Input to SYS Switch
On Voltage Drop
V
D_BSW
V
BATT
=3.5V, I
SYS
=600mA,
V
IN
=5V (Battery supplement mode),
CEB
= GND, MODE = GND
40 100 160 mV
BATT to SYS Short
Protection Current
I
BATT_MAX
V
BATT
=3.5V, V
SYS
=GND,
CEB
=5V
(guaranteed by design)
300 mA
BATT to SYS Switch
Leakage
V
BATT
=2.3V, V
IN
=V
SYS
=GND,
CEB
=5V
1 µA
SYS Reverse to BATT
Switch Leakage
V
SYS
=5V, V
IN
=V
BATT
=GND,
CEB
=5V
1 µA
Charge
r
Battery Voltage Regulation V
BATT
T = +25°C, I
BATT
= 0 4.179 4.20 4.221
V
T = 0°C to +50°C, I
BATT
= 0 4.168 4.20 4.232
T = –5°C to +75°C, I
BATT
= 0 4.158 4.20 4.242
IN to BATT Switch On
Resistance
R
ON_BATT
V
IN
=4.3V, V
BATT
=4.165V, I
CHG
=1A
200 400 m
Constant Current
Regulation for Charging
I
CHG
V
IN
= 5V, V
BATT
= 3.5V, MODE = 5V
R
CHG
= 2.263k
880 1000 1120 mA
V
IN
= 5V, V
BATT
= 3.5V, MODE = GND
R
CHG
= 7.6k
210 300 390 mA
Programmable Charge
Current
I
CHG
V
IN
= 5V, V
BATT
= 3.5V, MODE = 5V
1.5
(5)
A
MP2607 – LI-ION CHARGER WITH POWER PATH MANAGEMENT
MP2607 Rev. 1.03 www.MonolithicPower.com 5
5/18/2015 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited.
© 2015 MPS. All Rights Reserved.
ELECTRICAL CHARACTERISTICS
(5)
(continued)
V
IN
= 5.5V, V
BATT
= 3.5V, V
CEB
= GND, T
A
= 25°C, unless otherwise noted.
Paramete
r
Symbol Condition Min Typ Max Units
Charging current Thermal
Fold-back Threshold
105 120 135 °C
Constant Current Variation
for Charging
I
CHG
V
SYS
= 5V, V
BATT
= 3.5V
1.5k < R
CHG
< 7.6k
-12 12
%I
CHG
7.6k < R
CHG
< 22k -30 30
Trickle Charge Current
(
7
)
I
TRKL
V
BATT
= 2.0V, R
CHG
= 2.263k 5 8.5 12
%I
CHG
End of Charge (EOC)
current threshold
(8)
I
EOC
R
CHG
= 2.263k (1A I
CHG
) 7 10 13
%I
CHG
R
CHG
= 22.6k (100mA Ichg) 9 15 25 mA
Voltage at ICHSET pin
V
ICHSET
1.5k < R
CHG
< 4.5k
R
CHG
*I
C
HG
/201
6
R
CHG
*I
C
HG
/180
0
R
CHG
*I
C
HG
/158
4
V
Trickle Threshold Voltage V
TH TRKL
V
BATT
Rising
2.7 2.8 2.9 V
Trickle Voltage Hysteresis 190 mV
Auto Re-charge Fall
Threshold
V
RECHG
V
BATT
Falling
3.95 4.05 4.15 V
CEB
Threshold
Logic Low 0.3 V
CEB
Threshold
Logic High 2 V
CEB
pin Pull-up Resistor
1 M
STAT1
,
STAT2
Sink
Current
Pin Voltage = 0.3V 8 mA
Battery Reverse Current to
IN pin
IN pin grounded, V
BATT
= 4.3V
1 µA
Timer for Charging
τ
TMR_F
C
TMR
=1µF, R
CHG
=2.263k (1A I
CHG
) 1.1 Hour
C
TMR
=1µF, R
CHG
=22.6k (100mA
I
CHG
)
8.4 Hour
Timer Count
C
TMR F
2
17
C
TMR T
2
15
Timer Accuracy
R
CHG
=2.263k (1A I
CHG
)
-20 20 %
R
CHG
=22.6k (100mA I
CHG
)
-40 40 %
NTC pin Output Current I
NTC
CEB
= GND
-100 0 100 nA
Temperature Fault
Threshold Voltage
V
TH LT
Ambient Temp = 0°C 58 60 62 %V
IN
V
TH HT
Ambient Temp = 50°C 28 30 32 %V
IN
Notes:
5) Min. VIN is determined by internal UVLO and relative to BATT voltage
6) High Charge current make MP2607 get into thermal fold-back and charge current will drop down.
7) I
CHG
is the target preprogrammed charge current (Die temperature below 110°C), i.e. typical value of I
CHG
.
8) I
EOC
is the target preprogrammed battery full current threshold, i.e. typical value of I
EOC
.
MP2607 – LI-ION CHARGER WITH POWER PATH MANAGEMENT
MP2607 Rev. 1.03 www.MonolithicPower.com 6
5/18/2015 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited.
© 2015 MPS. All Rights Reserved.
PIN FUNCTIONS
Pin # Name I/O Description
1, 2 BATT I/O Connected to battery
3 MODE I Input select for AC adapter or USB port
4 ICHSET O Connected to an external resistor to set charging current ICHG
5 TMR I
Program pin to set timer for the charger with an external capacitor; 470nF
equivalents to 1 hour if R
CHG
is 4.2k
6
CEB
I
Enable pin for MP2607.
CEB
high (>2V) disables IN (AC or USB) regulation path
and charger, the system is supplied only from battery
7 GND Power Ground
8 NTC O Battery temperature sense pin, connected to the thermistor of battery pack
9
STAT2
O
Charging status indication pin: 1. charging; 2. end of charge; 3. charge suspend;
4. Fault
10
STAT1
O
11, 12 IN Power Input for AC adapter or USB port
13, 14 SYS Power System power supply.

MP2607DL-LF-P

Mfr. #:
Manufacturer:
Monolithic Power Systems (MPS)
Description:
Battery Management Li-ion charger with power path mgt
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union