ESE-18R61D

Detector Switches/ESE18
1 2 3 4 5 6 7 8 9
Product Code
Design No
6th
L
R
Left-side operation type
Right-side operation type
Type
1HL Detector Switches
Type:
ESE18
Features
Thin body: 1.2 mm
Circuit type: Normally-open and normally-closed
types are available.
Travel: Standard stroke type: 1.5 mm
Long stroke type: 2.15 mm
Surface mounted type: Packed with embossed tape.
Supports refl ow soldering.
Recommended Ap pli ca tions
Detection of media in portable electronic equipment
(Mobile phones/CD-ROM/DVD players, Digital still cameras)
Explanation of Part Numbers
gnitaR
m 005ecnatsiseR tcatnoC Ω max. (Initial)
M 001ecnatsiseR noitalusnI Ω min. (100 V DC)
egatloV gnidnatshtiW cirtceleiD
.xam Nm 003ecroF gnitarepO
mm 2.1thgieH gnitnuoM
worht-1 elop-1sworhT dna seloP
Full Travel (Pushing distance)
· Standard stroke type · Long stroke type
With boss : 1.4 mm (1.5 mm) With boss : 1.4 mm (2.15 mm)
Without boss : 2.1 mm (1.5 mm) Without boss : 2.1 mm (2.15 mm)
.nim selcyc 00,005efiL gnitarepO
C° 06+ ot C°
01egnaR erutarepmeT
sruoh 69 rof C° 07+ecnatsiseR taeH
sru
oh 69 rof C° 52ecnatsiseR erutarepmeT woL
sruoh 69 rof HR % 59 ot % 09 C° 04+ecnatsiseR ytidimuH
)kcaP leeR( gnipaT dessobmE .scp 00,05tinU gnikcaP/ytitnauQ muminiM
.scp 00,003notraC/ytitnauQ
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
ANCTB49E 201701-Fd
Panasonic Corporation 2017
–1–
industrial.panasonic.com/ac/e/
2017.01
50 μA 3 V DC to 10 mA 5 V DC (Resistive load)
100 V AC for 1 minute
ANCTB.indb 29 17/01/23 18:15
Detector Switches/ESE18
(52.4°)
(14.7°)
0.25
1.0
0.75
0.7
0.4
3.4
2.0±0.1
φ0.6±0.05
(1.2)
1.2±0.2
0.25
0.25
0.5
0.5
0.65
4.0
2.7
0.5
0.5
1.0
(3.2)
0.7
1.4
(2.0)
3.1
3.55
0.54
R0.3
3.2
3.8
3.0
1.2
3.6
0.25
1.15
5.4
1.8
Full stroke position
(Pivot center)
Pivot center
Operation point
Case center
ON start position
OFF start position
ON start position
OFF start position
ON angular terminal
OFF angular terminal
3.6
1.8
4.1
3.0
1.2
0.25
1.15
3.2
5.4
1.2±0.2
0.4
0.25
3.4
2.0±0.1
φ
0.6±0.05
1.0
(1.2)
2.9
0.5
0.5
2.6
(2.0)
1.4
0.7
0.7
0.75
0.5
2.7
4.0
0.5
0.54
0.65
R0.3
2.6 max.
(14.7˚)
(52.4˚)
1.0
Full stroke position
(Pivot center)
Pivot center
Operation point
Dummy terminal
Case center
ON start position
OFF start position
ON start position
OFF start position
ON angular terminal
OFF angular terminal
A
c
t
i
o
n
d
i
r
e
c
t
i
o
n
(1.2)
1.0
0.25
(52.4°)
(14.7°)
0.65
R0.3
2.6 max.
0.54
0.25
0.4
0.5
0.5
2.7
4.0
1.2±0.2
φ0.6±0.05
3.4
0.5
2.9
2.6
(2)
1.4
1.0
0.75
0.7
0.7
0.5
0.25
2.0±0.1
5.4
3.2
1.8
3.6
0.25
1.15
3.0
1.2
3.8
Operation point
Full stroke position
ON start position
OFF start position
ON start position
OFF start position
Pivot center
Pivot center
ON angular terminal
OFF angular terminal
Dummy terminal
Case center
A
c
t
i
o
n
d
i
r
e
c
t
i
o
n
Long stroke type
ESE18L J-bent terminals
1-pole 1-throw
Normal open
with Boss
ESE18L12B
Normal open
without Boss
ESE18L12A
Normal closed
with Boss
ESE18L62B
Normal closed
without Boss
ESE18L62A
No. 1
Normal open
with Boss
ESE18L11B
Normal open
without Boss
ESE18L11A
Normal closed
with Boss
ESE18L61B
Normal closed
without Boss
ESE18L61A
Standard stroke type
ESE18L Straight ter mi nals
1-pole 1-throw
Standard stroke type
ESE18L J-bent terminals
1-pole 1-throw
No. 2
Normal open
with Boss
ESE18L11D
Normal open
without Boss
ESE18L11C
Normal closed
with Boss
ESE18L61D
Normal closed
without Boss
ESE18L61C
No. 3
Dimensions in mm (not to scale)
PWB mounting hole for reference
(Pitch tolerance: ±0.05)
PWB mounting hole for reference
(Pitch tolerance: ±0.05)
PWB mounting hole for reference
(Pitch tolerance: ±0.05)
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
ANCTB49E 201701-Fd
Panasonic Corporation 2017
industrial.panasonic.com/ac/e/
Panasonic Corporation
Electromechanical Control Business Division
–2–
ANCTB.indb 30 17/01/23 18:15
Detector Switches/ESE18
A
c
t
i
o
n
d
i
r
e
c
t
i
o
n
(1.2)
1.0
2.9
2.0±0.1
3.4
0.4
0.25
1.2±0.2
2.6
1.4
(2.0)
1.0
0.75
0.7
0.5
0.7
0.5
0.5
2.7
4.0
0.5
Full stroke position
(Pivot center)
Operation point
0.54
R0.3
0.65
2.6 max.
Pivot center
Dummy terminal
Case center
(14.7 ˚)
(52.4 ˚)
3.2
5.4
1.2
3.6
1.8
4.1
3.0
0.25
1.15
ON start position
OFF start position
ON start position
OFF start position
ON angular terminal
OFF angular terminal
Full stroke position
(Pivot center)
Pivot center
Operation point
Case center
ON start position
OFF start position
ON start position
OFF start position
ON angular terminal
OFF angular terminal
(52.4°)
(14.7°)
0.25
1.0
0.75
0.7
0.4
3.4
2.0±0.1
φ
0.6±0.05
(1.2)
1.2±0.2
0.5
0.65
4.0
2.7
0.5
1.0
(3.2)
0.7
1.4
(2.0)
3.1
3.55
0.54
R0.3
3.2
4.1
3.0
1.2
3.6
0.25
1.15
5.4
1.8
0.5
(1.2)
1.0
0.25
(52.4°)
(14.7°)
0.65
R0.3
2.6 max.
5.4
3.2
1.8
3.6
0.25
1.15
3.0
1.2
3.8
0.54
0.25
0.4
0.5
0.5
2.7
4.0
1.2±0.2
3.4
0.5
2.9
2.6
(2)
1.4
1.0
0.75
0.7
0.7
0.5
0.25
2.0±0.1
Operation point
Full stroke position
Pivot center
Pivot center
Dummy terminal
Case center
ON start position
OFF start position
ON angular terminal
OFF angular terminal
A
c
t
i
o
n
d
i
r
e
c
t
i
o
n
No. 4
Normal open
with Boss
ESE18R11D
Normal open
without Boss
ESE18R11C
Normal closed
with Boss
ESE18R61D
Normal closed
without Boss
ESE18R61C
Standard stroke type
ESE18R Straight terminals
1-pole 1-throw
Long stroke type
ESE18L Straight ter mi nals
1-pole 1-throw
No. 5
No. 6
Normal open
with Boss
ESE18L12D
Normal open
without Boss
ESE18L12C
Normal closed
with Boss
ESE18L62D
Normal closed
without Boss
ESE18L62C
Dimensions in mm (not to scale)
PWB mounting hole for reference
(Pitch tolerance: ±0.05)
PWB mounting hole for reference
(Pitch tolerance: ±0.05)
PWB mounting hole for reference
(Pitch tolerance: ±0.05)
Standard stroke type
ESE18R J-bent terminals
1-pole 1-throw
Normal open
with Boss
ESE18R11B
Normal open
without Boss
ESE18R11A
Normal closed
with Boss
ESE18R61B
Normal closed
without Boss
ESE18R61A
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
ANCTB49E 201701-Fd
Panasonic Corporation 2017
industrial.panasonic.com/ac/e/
Panasonic Corporation
Electromechanical Control Business Division
–3–
φ
0.6±0.05
φ
0.6±0.05
ANCTB.indb 31 17/01/23 18:15

ESE-18R61D

Mfr. #:
Manufacturer:
Panasonic
Description:
Detector Switches SPST-NC w/boss Right Std lv
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: