6
Electrical Speci cations (DC)
Over recommended operating T
A
= - 40°C to 85°C, I
F
= 5mA to 10mA, unless otherwise speci ed.
Parameter Sym. Min. Typ. Max. Units Conditions Fig. Note
Output Withstand Voltage |
VO(OFF)
|60 68 V V
F
=0.8V, I
O
=250µA, T
A
=25°C 3
55 V V
F
=0.8V, I
O
=250µA 3
Output Leakage Current I
O(OFF)
0.01 0.1 µA V
F
=0.8V, V
O
=60V, T
A
=25°C 5
5µAV
F
=0.8V, V
O
=55V 4
Output O -Capacitance C
(OFF)
1400 pF V
F
=0.8V, V
O
=0V, f=1MHz 6
Output O set Voltage | V
(OS)
| 1 µV I
F
=5mA, I
O
=0mA
Input Reverse Breakdown
Voltage
V
R
5VI
R
=10µA
Input Forward Voltage V
F
1.1 1.3 1.7 V I
F
=5mA 7, 8
Output On-
resistance
Connection A R
(ON)
0.065 0.1 Ω I
F
=5mA, I
O
=2.5A,
Pulse ≤30ms, T
A
=25°C
9, 10 5
11
Connection B
0.02 0.035 Ω
Switching Speci cations (AC)
Over recommended operating T
A
= - 40°C to 85°C, I
F
= 5mA to 10mA, unless otherwise speci ed.
Parameter Sym. Min. Typ. Max. Units Conditions Fig. Note
Turn On Time T
ON
3.2 5.0 ms I
F
=5mA, I
O
=1.0A, T
A
=25°C 12, 13
10.0 ms I
F
=5mA, I
O
=1.0A
1.6 2.5 ms I
F
=10mA, I
O
=1.0A, T
A
=25°C 12, 14
5.0 ms I
F
=10mA, I
O
=1.0A
Turn O Time T
OFF
0.1 0.5 ms I
F
=5mA, I
O
=1.0A, T
A
=25°C 15, 16
1msI
F
=5mA, I
O
=1.0A
0.06 0.2 ms I
F
=10mA, I
O
=1.0A, T
A
=25°C 15, 17
0.5 ms I
F
=10mA, I
O
=1.0A
Output Transient
Rejection
dV
O
/dt 1 7 kV/µs ∆V
O
=60V, R
M
≥ 1M,
C
M
=1000pF, T
A
=25°C
6
Input-Output
Transient Rejection
dVI
-O
/dt 1 ≥10 kV/µs V
DD
=5V, ∆VI
-O
=1000V,
R
L
=1k, C
L
=25pF, T
A
=25°C
6
Notes:
1. For derating, refer to Figure 1 and 2.
2. The voltage across the output terminals of the relay should not exceed this rated withstand voltage. Over-voltage protection circuits should be
added in some applications to protect against over-voltage transients.
3. Device is considered as a two terminal device: pins 1, 2, and 3 shorted together and pins 5, 6, and 7 shorted together.
4. The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous voltage
rating. For the continuous voltage rating refer to the IEC/EN/DIN EN 60747-5-2 Insulation Characteristics Table (if applicable), your equipment level
safety speci cation, or Avago Application Note 1074, “Optocoupler Input-Output Endurance Voltage.”
5. During the pulsed R
(ON)
measurement ( I
O
duration ≤30ms), ambient (T
A
) and case temperature (T
C
) are equal.
6. For the transient rejection measurements, refer to Avago whitepaper, AV01-0610EN, “Solid State Relay Transient Immunity”.