CPC/CPCL and CPX/CPXL Series
2 www.honeywell.com/sensing
ELECTRICAL SPECIFICATIONS
CPC/CPCL at 12 Vdc, 25 °C [77 °F] CPX/CPXL at 5 Vdc, 25 °C [77 °F]
Characteristic
Min. Typ. Max. Unit
Min. Typ. Max.
Unit
Excitation voltage 3.0 12.0 16.0 Vdc 3.0 5.0 12.0 Vdc
Null -1.0 0 1.0 mV -50 0 50 mV
Offset temperature shift
(1)
0 °C to 25 °C [32 °F to 77°F]
25 °C to 70 °C [77 °F to 158 °F]
(2)
– – ±1.0
mV – ±0.5 mV
Full scale temperature shift
2
0 °C to 25 °C [32 °F to 158 °F]
25 °C to 70 °C [77 °F to 158 °F]
(2)
– – ±2
PPM/°C – -2200 – PPM/°C
Linearity, hysteresis error
(3)
– 0.25 1.0 % span 0.25 1.0 % span
Input resistance 5.0 – – kOhm 5.0 – – kOhm
Output resistance – 3.0 – kOhm – 3.0 – kOhm
Operating temperature -25 [-13] – 85 [185] °C [°F] -25 [-13] – 85 [185] °C [°F]
Storage temperature -40 [-40] – 125 [257] °C [°F] -40 [-40] – 125 [257] °C [°F]
Common mode pressure – – 50 psi – – 50 psi
Weight – 2 – g – 2 – g
Notes:
1. Pressure specs obtained with pressure applied to the front of the sensor.
2. Shift is relative to 25 °C [77 °F].
3. Measured at ½ full scale rated pressure using BFSL.
ABSOLUTE OUTPUT
CPC at 12 Vdc, 25 °C [77 °F]
Output Full Scale Span (mV)
CPX at 5 Vdc, 25 °C [77 °F]
Output Full Scale Span (mV)
Overpressure
(psi)
FS Pressure
Min. Typ. Max. Min. Typ. Max. Max.
5 psi 57 60 63 112 168.5 225 15
15 psi 85 90 95 168 253 338 45
30 psi 85 90 95 168 253 338 90
60 psi 85 90 95 189 263.5 338 180
100 psi 95 100 105 210 295 380 250
GAGE/DIFFERENTIAL
(1)
OUTPUT
CPC/CPCL at 12 Vdc, 25 °C [77 °F]
Output Full Scale Span (mV)
CPX/CPXL at 5 Vdc, 25 °C [77 °F]
Output Full Scale Span (mV)
Overpressure
(psi)
FS Pressure
Min. Typ. Max. Min. Typ. Max. Max.
4 in H
2
O 23 25 27 50 68 86 3
10 in H
2
O 19 20 21 40 78.5 112 3
1 psi 17 18 19 40 75 110 3
5 psi 57 60 63 112 168.5 225 15
15 psi 85 90 95 168 253 338 45
30 psi 85 90 95 168 253 338 90
60 psi 85 90 95 189 263.5 338 180
100 psi 95 100 105 210 295 380 250
150 psi 85 90 95 187 262.5 338 250
Note:
1. Differential common mode pressure should not exceed 50 psi.