MPS-30-15

SPECIFICATION
MPS-30-5 MPS-30-12 MPS-30-15 MPS-30-24 MPS-30-27 MPS-30-48
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
OVER TEMPERATURE
AC CURRENT (Typ.)
5V 12V 15V 24V 27V 48V
5A 2.5A 2A 1.2A 1.1A 0.6A
0 ~ 5A 0 ~ 2.5A 0 ~ 2A
0 ~ 1.2A
0 ~ 1.1A 0 ~ 0.6A
25W 30W 30W 28.8W 29.7W 28.8W
80mVp-p 120mVp-p 150mVp-p 240mVp-p 240mVp-p 240mVp-p
±3.0% ±3.0% ±3.0% ±3.0% ±3.0% ±2.0%
±1.0% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5%
±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
88 ~ 264VAC auto switch 120 ~ 370VDC
47 ~ 63Hz
72% 75% 76% 77% 78% 78%
0.8A/115VAC 0.5A/230VAC
COLD START 30A/230VAC
Above 105% rated output power
5.5 ~ 6.75V 13.2 ~ 16.2V 16.5 ~ 20.25V 26.4 ~ 32.4V 29.7 ~ 36.45V 52.8 ~ 64.8V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Shut down o/p voltage, re-power on to recover
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-20 ~ +85 , 10 ~ 95% RH
±℃ 0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
547Khrs min. MIL-HDBK-217F (25 )
101.6*65.8*23.5mm (L*W*H)
0.16Kg; 90pcs/15.8Kg/1.02CUFT
File Name:MPS-30-SPEC 2015-08-06
500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load
70ms/230VAC 12ms/115VAC at full load
-10 ~ +60 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
SAFETY STANDARDS
ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1 approved
Compliance to EN55011 (CISPR11) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, medical level, criteria A
30W Single Output for Medical Type
MPS-30 series
Universal AC input / Full range
Low leakage current <200 A
Protections: Short circuit / Overload / Over voltage / Over temperature
Medical safety approved (2 x MOPP between primary to secondary)
Fixed switching frequency at 100KHz
Low cost
High reliability
3 years warranty
Features :
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:SHORT
I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25 / 70% RH
ENVIRONMENT
SAFETY &
EMC
(Note 4)
PROTECTION
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.360 360 For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
5. When the input vlotage is less than 40VAC, the SPS may exhibit degradation of performance. The final product manufacturers must re-confirm this
deviation that does not affect basic safety or essential performance.
EMC IMMUNITY
EMC EMISSION
Earth leakage current < 200 A/264VAC
μ
μ
ISOLATION LEVEL
Primary-Secondary: 2xMOPP, Primary-Earth:1xMOPP
EN 60601-1
IEC 60601-1
8
File Name:MPS-30-SPEC 2015-08-06
Unit:mm
fosc : 100KHz
DC Output Connector (CN2) : Molex 41791-4 or equivalent
Pin No.
1,2
3,4
Assignment
-V
+V
Mating Housing
Molex 2139
or equivalent
Terminal
Molex 2478
or equivalent
AC Input Connector (CN1) : Molex 41791-5 or equivalent
Pin No.
1
3
5
2,4
Assignment
AC/L
AC/N
FG
No Pin
Mating Housing
Molex 2139 Molex 2478
or equivalent or equivalent
Terminal
AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (V) 60Hz
LOAD (%)
OUTPUT VOLTAGE (V)
(HORIZONTAL)
Block Diagram
Mechanical Specification
Static Characteristics
1
2
3
4
1
2
3
4
5
CN1
T2.5A 250V
FUSE*2
CN2
95.2
101.6
66.1
3.2
3.2
M3 L=6mm
23.5 max.
-100102030405060
20
40
60
80
100
20080
8
60
12
16
20
24
140100 120 180160
28
32
264240220
50
100
150
200
250
300
350
OUTPUT RIPPLE (mVp-p)
51.4
4- 3.2ψ
18
65.8
62.6
Derating Curve
2 max.
+V
-V
CROWBAR
OVP
FILTER
FG
I/P
EMI
FILTER
RECTIFIERS
&
RECTIFIERS
CONTROL
SWITCHING
PWM
POWER
DETECTION
CIRCUIT
&
FILTER
30W Single Output for Medical Type
MPS-30 series
: Grounding Required
CN1:Pin 1 is safety ground

MPS-30-15

Mfr. #:
Manufacturer:
Description:
Switching Power Supplies 30W 15V 2A
Lifecycle: