64
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
For email, phone or live chat, please go to
te.com/help
corcom.com
R Series
Two-stage General Purpose RFI Power Line Filter (continued)
Performance Data
Typical Insertion Loss
Minimum Insertion Loss
Common Mode / Asymmetrical (Line to Ground)
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (L-G)
Differential Mode / Symmetrical (L-L)
Measured in closed 50 Ohm system
Differential Mode / Symmetrical (Line to Line)
1ER
0.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
0
3ER 5ER 2ER, 10ER & 20ER
0.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
0
0.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
0
0.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
0
1VR
0.1 1 10 30
Frequency in MHz
100
90
80
70
60
50
40
30
20
10
0
2VR 3VR 5VR
0.1 1 10 30
Frequency in MHz
100
90
80
70
60
50
40
30
20
10
0
0.1 1 10 30
Frequency in MHz
100
90
80
70
60
50
40
30
20
10
0
0.1 1 10 30
Frequency in MHz
100
90
80
70
60
50
40
30
20
10
0
10VR
0.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
0
20VR
0.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
0