MPDTH_60 Series.A08 Page 2 of 6
www.murata-ps.com
MPDTH***60 Series
Adjustable Non-isolated 10-Amp
POLA DC/DC Converters
www.murata-ps.com/support
SPECIFICATION SUMMARY AND ORDERING GUIDE
Output
Input (9)
Vout Iout (Amps, Power Ripple&Noise Regulation Vin nom. Range Effi ciency Package
Model Number
(Volts) max.) (Watts) (mV pk-pk) Line Load (Volts) (Volts) (%) Case(inches) Case(mm) Type(2)
MPDTH03060WAH 0.8-2.5 10 25 25(6) ±1.25% ±1.5% 3.3 3-3.6 93(3) 0.995x0.62x0.35 25.27x15.75x9.0 TH
MPDTH03060WAS 0.8-2.5 10 25 25(6) ±1.25% ±1.5% 3.3 3-3.6 93(3) 0.995x0.62x0.38 25.27x15.75x9.57 SM
MPDTH05060WAH 0.8-3.6 10 36 25(7) ±1.25% ±1.5% 5.0 4.5-5.5 94(4) 0.995x0.62x0.35 25.27x15.75x9.0 TH
MPDTH05060WAS 0.8-3.6 10 36 25(7) ±1.25% ±1.5% 5.0 4.5-5.5 94(4) 0.995x0.62x0.38 25.27x15.75x9.57 SM
MPDTH12060WAH 1.2-5.5 10 55 33(8) ±1.25% ±1.5% 12.0 10.8-13.2 94(5) 0.995x0.62x0.35 25.27x15.75x9.0 TH
MPDTH12060WAS 1.2-5.5 10 55 33(8) ±1.25% ±1.5% 12.0 10.8-13.2 94(5) 0.995x0.62x0.38 25.27x15.75x9.57 SM
Input
Input Voltage Range See Ordering Guide
Start-Up Voltage 2.45 Volts (MPDTH03060)
4.3 Volts (MPDTH05060)
9.5 Volts (MPDTH12060)
Undervoltage Shutdown 2.4 Volts (MPDTH03060)
3.7 Volts (MPDTH05060)
9.0 Volts (MPDTH12060)
External Input Capacitor
(See note 3)
330 µF, required (MPDTH03060 and
MPDTH05060)
560 µF required (MPDTH12060)
Remote On/Off Inhibit Control
Positive Logic
Current
OFF = -0.2V to +0.5 V max. or ground pin
ON = open pin (internal pullup)
-130 µA [5]
Tracking Input
Current when grounded
Slew rate
Tracking Input Range
-130 µA
1 Volt per mSec max.
-0.3V to (+Vin + 0.3V)
Margin Controls -5% or +5% adjustment of Vout when the
respective margin control is grounded. Current,
-8 µA sink.
Output
Minimum Loading No minimum load
Nominal Accuracy ±2 % max. of Vsetting
Voltage Adjustment Range See Ordering Guide
Temperature Coeffi cient ±40 ppm. per °C. of Vout
Ripple/Noise See Ordering Guide
Line/Load Regulation See Ordering Guide
Effi ciency See Ordering Guide
Maximum Capacitive Loading
Cap-ESR>=0.004 Ohms
Cap-ESR <0.004 Ohms
5,500 µF non-ceramic [2]
300 µF ceramic
Current Limit Inception 20 Amps
Short Circuit Mode
Protection Method
Short Circuit Duration
Autorecovery after overload removal
Continuous, no damage (output shorted to
ground)
Sequencing Start-up of multiple units may be synchronized
by connecting tracking pins.
VoSense Input Connect Sense to Vout remotely at the load for
optimal accuracy. If not used at the load, con-
nect VoSense to Vout at the converter.
Dynamic Characteristics
Dynamic Load Response 70 µSec to within ±2% of fi nal value (50 to
100% load step, 1A/µSec load step, 330 µF
external output cap)
Switching Frequency 300 KHz (MPDTH03060 and MPDTH05060)
350 KHz (MPDTH12060)
Environmental
Calculated MTBF [4] 6 million hours,min. (MPDTH03060 and
MPDTH03060)
5.9 million hours,min. (MPDTH12060)
Operating Temperature Range -40 to +85 deg.C.
Storage Temperature Range -40 to +125 deg.C.
MPDTH**060 Series Performance and Functional Specifi cations
All specifi cations are typical unless noted.
Notes:
All specifi cations are typical at nominal input line voltage, nominal output voltage and full load,
Ta=+25 deg.C. unless otherwise noted. See detailed specifi cations.
"TH" is a pinned through-hole package. "SM" is a surface mount package.
Vin=3.3V, Vout=2.5V, Iout=7A
Vin=5V, Vout=3.3V, Iout=7A
Vin=12V, Vout=5V, Iout=8A
Vin=3.3V, Vout=2V, Iout=10A
Vin=5V, Vout=3.3V, Iout=10A
Vin=12V, Vout=3.3V, Iout=10A
The minimum input voltage is +2.95V. Or (Vout + 0.65V.), whichever is greater.
RoHS6 compliance does not claim EU RoHS exemption 7b (lead in solder).
Specifi cation Notes:
(1) All specifi cations are typical unless noted. General conditions for Specifi cations are +25 deg.C
ambient, Vin=nominal, Vout=+2.5V, full load. Cin=100
µF, Cout= 0 µF. Adequate airfl ow must be
supplied for extended testing under power. For model MPDTH12060, the required input capaci-
tor is 560
µF. See note 3.
(2) An external output capacitor is not required. However, a 330
µF output capacitor improves
transient response.
(3) The required input capacitor must have a ripple current rating of 500 mA RMS or greater for
models MPDTH03060 and MPDTH05060. For model MPDTH12060, the ripple rating must be
1050 mA RMS or greater.
(4) Mean Time Before Failure is calculated using the Telcordia (Belcore) TR-332 50% stress, ground
benign conditions, Tambient=+40 deg.C.
(5) Track input is grounded or equal to Vin.
(6) There is no input protection against overvoltage or reversed polarity. Please provide proper
fusing and a back-biased diode if there is the possibility of improper polarity. Refer to the Con-
nection Diagram.
(7) The outputs are not intended to sink appreciable reverse current.
(8) Output current limit and short circuit protection is non-latching. When the overcurrent fault is
removed, the converter will immediately recover.