5. UV Sensor Optical Filter
An optical UV transmission filter is recommended with the usage of ML8511. The material recommended is
ACRYLITE #000 (1.0mm thickness) with sandblast #220, if opaque filter is desired. The distance from ML8511
to filter is D1. D1 should be ~1.0mm. The aperture size of the filter is D2. D2 should be ~3.0mm.
6. Output Voltage – UV Characteristics
The below chart shows the linear relationship between the sensors output voltage and UV
intensity (mW/cm
2
) when Vdd = 3.0V. The sensor output is stable across the operating
temperature range.
ML8511-00FC_REFBOARD_Manual
FEBL8511_REFBOARD_Manual-01
4/7
7. Spectral Response Characteristics
The ML8511 has the spectral response of measuring UVA and UVB wavelengths.
UV-A: 315-400nm
UV-B: 280-315nm
ML8511-00FC_REFBOARD_Manual
FEBL8511_REFBOARD_Manual-01
5/7
8. Reference Board Schematic
The schematic below shows the reference board inputs/outputs and pin connections.