NCS37010
www.onsemi.com
4
ABSOLUTE MAXIMUM RATINGS
Rating Symbol Value Unit
Supply Voltage Range Vs 6.0 to 12 V
Input Voltage Range (Note 1) V
in
−0.3 to 6.0 V
Output Voltage Range V
out
−0.3 to 6.0 V or (V
in
+ 0.3),
whichever is lower
V
Maximum Junction Temperature T
J(max)
140 °C
Storage Temperature Range T
STG
−65 to 150 °C
ESD Capability, Human Body Model (Note 2) ESD
HBM
2 kV
ESD Capability, Machine Model (Note 2) ESD
MM
200 V
Lead Temperature Soldering
Reflow (SMD Styles Only), Pb−Free Versions (Note 3)
T
SLD
260 °C
Stresses exceeding those listed in the Maximum Ratings table may damage the device. If any of these limits are exceeded, device functionality
should not be assumed, damage may occur and reliability may be affected.
1. Refer to ELECTRICAL CHARACTERISTICS and APPLICATION INFORMATION for Safe Operating Area.
2. This device series incorporates ESD protection and is tested by the following methods:
ESD Human Body Model tested per AEC−Q100−002 (EIA/JESD22−A114)
ESD Machine Model tested per AEC−Q100−003 (EIA/JESD22−A115)
Latchup Current Maximum Rating: v150 mA per JEDEC standard: JESD78
3. For information, please refer to our Soldering and Mounting Techniques Reference Manual, SOLDERRM/D
THERMAL CHARACTERISTICS
Rating Symbol Value Unit
Thermal Characteristics, QFN16, 3x3.3 mm (Note 4)
Thermal Resistance, Junction−to−Air (Note 5)
R
θJA
64 °C/W
Thermal Characteristics, TSSOP−20 (Note 4)
Thermal Resistance, Junction−to−Air (Note 5)
R
θJA
See note above. °C/W
4. Refer to ELECTRICAL CHARACTERISTICS and APPLICATION INFORMATION for Safe Operating Area.
5. Values based on copper area of 645 mm
2
(or 1 in
2
) of 1 oz copper thickness and FR4 PCB substrate.
OPERATING RANGES (Note 6)
Parameter
Conditions Min Typ Max Unit
Operating Temperature −40 85 C
IDD in typical power state 2 mA
Stimulus Generator Frequency Tri−tone 3.1 3.4 kHz
SCR Trigger Current 8 mA
SCR Trigger output voltage With 5 V supply 4.5 5.5 V
Fault Current Sensitivity Programmable with CTresD 4.6 4.8 5 mA
Ground Fault Response Time 5 − 20 mA 150 ms
Ground Fault Response Time 20 − 40 mA 75 ms
Ground Fault Response Time >40 mA 25 ms
Saturation Fault Response Time >300 mA 1.4 ms
CT Turns Ratio 200 300
Ground − Neutral Detection Threshold Total series impedance (Rn and Rg) 3 6
W
Internal Oscillator Frequency 2 MHz
CT Stimulus Current Internally limited 1 mA
CT Driver Closed Loop BW 500 KHz
Product parametric performance is indicated in the Electrical Characteristics for the listed test conditions, unless otherwise noted. Product
performance may not be indicated by the Electrical Characteristics if operated under different conditions.
6. Refer to ELECTRICAL CHARACTERISTICS and APPLICATION INFORMATION for Safe Operating Area.