RAC48-05S/OF

POWERLINE
AC/DC-Converter
with 3 year Warranty
RAC48/OF
48 Watt
Open Frame
Single Output
Connector Set available
Class II Power Supply
Universal Input Voltage Range
compact 4“ x 2“ size
3kVAC Isolation
OCP, OVP, SCP
Standby Power ErP conform (<0.5W)
Features
Regulated
Converters
Selection Guide
Part Input Output Output Voltage Adj. Output Efficiency Max.
Number Range Voltage Current Range Range * Power typ. Capacitive
(VAC) (VDC) (A) (V) (W) % Load
RAC48-05S/OF 90-264 5 0-8 4.8-5.2 40 79 18800µF
RAC48-12S/OF 90-264 12 0-4 11.4-12.6 48 82 18800µF
RAC48-15S/OF 90-264 15 0-3.2 14.2-16 48 84 12700µF
RAC48-24S/OF 90-264 24 0-2 23-25 48 85 4700µF
* refer to „Package Style and Pinning“
Input Voltage Range 90-264VAC or 127-370VDC
Rated Power 48 Watts max.
Input Frequency Range (for AC Input) 47-63Hz
Operating Frequency 65kHz typ.
Input Current (full load) 115VAC 1.5A max.
230VAC 1A max.
Inrush Current (Cold Start) 115VAC 30A typ.
230VAC 60A typ.
No Load Power Consumption <0.5W
Start-up Time (at cold first start) 115VAC/230VAC 500ms
Rise Time Full Load <30ms
Hold Time 115VAC, Full Load 13ms typ.
230VAC, Full Load 60ms typ.
Leakage Current 240VAC <0.75mA
Output Voltage Accuracy 24VDC ±1%
(includes Line-, Load-regulation and Set-up Tolerance) 05, 12, 15VDC ±2%
Output Ripple and Noise (20MHz limited) 5VDC 80mVp-p max.
12VDC 120mVp-p max.
15VDC 150mVp-p max.
(measured with 0.1μF & 47μF parallel capacitor) 24VDC 200mVp-p max.
Isolation Voltage I/P to O/P 3kVAC / 1 minute
I/P to FG 1.5kVAC / 1 minute
O/P to FG 0.5kVAC / 1 minute
Isolation Resistance 500VDC 100 MΩ
Short Circuit Protection Hiccup Mode, Automatic Restart
Over Voltage Protection 5VDC 5.75-6.5VDC
12VDC 13.5-15VDC
15VDC 16.9-18.75VDC
Latch Mode, re-power on to recover 24VDC 27-30VDC
Over Load Protection 115-150% rated output power, Hiccup Mode, Automatic Restart
continued on next page
100
60
40
0
80
Ambient Temperature Range (°C)
20
0
50
Output Power (%)
70
50
-20
20
Description
Specifications
(typical at 25°C and 230VAC)
The RAC48/OF series offers compact AC/DC open frame power supplies
with universal AC input (90-264VAC) and fully protected DC outputs which
are trimmable to compensate for voltage drops on the output connections.
The power supplies are CB, UL, and CE certified and ErP conform.
Uses include industry controls, test and measurement systems and energy
efficient products.
CB-Report
UL-60950-1 Certified
EN-60950-1 Certified
EN-55022 Certfied
EN-55024 Certified
E196683
RoHS
2011/65/EU
6/6
Derating-Graph
(Ambient Temperature)
www.recom-power.com PA-53REV: 3/2017
POWER LED
1
2
3
4
1
2
CN1
CN2
VR
A
B
101.6
95.3
50.8
44.5
3.175
4x 3.3
3.175
30
TRIM
F.G.
F.G.
RAC48-xx/OF
Series
POWERLINE
AC/DC-Converter
Specifications
(typical at 25°C and 230VAC)
Package Style and Pinning
AC Input Connector (CN1):
Pin# Terminal Mating Housing
1 AC/N
WST I39606PS-2 WST P3-I39606
or equivalent or equivalent
2 AC/L
Operating Temperature Range Full Load without derating -20°C to +50°C
with derating -20°C to +70°C
Storage Temperature Range -40°C to +80°C
Operation Humidity non-condensing 20% - 90% RH
Storage Humidity 10% - 90% RH
Vibration 10-500Hz, 2G, 10 Min. along X, Y and Z
Weight 145g
Dimensions (LxWxH) 101.6 x 50.8 x 30mm
Package Quantity 30pcs / carton
Package Dimensions Carton (LxWxH) 325 x 270 x 220mm
MTBF (using MIL-HDBK-217F, 25°C) >450 x 10³ hours
Certifications:
General Safety Report: E196683 UL-60950-1 2nd
IEC/EN General Safety Report: PSE103-0658 IEC/EN-60950-1 2nd
EMC Conducted and Radiated Report: HA080035-SCCE EN55022, Class B
Immunity Report: HA080035-SCCE EN55024
Report: HA080035-SBFD FCC, Part 15, Class B
Harmonics Report: HA080035-SCCE EN61000-3-2
EN61000-3-3
EN61000-4-2, 3, 4, 5, 6, 8, 11, Critertia A
Emission Report: HA080035-SCCE EN61000-6-3
ErP complies to European Directive for Energy Related Products 2004/125/EC
Notes
Note1: Mounting holes A, B must be grounded for EMI (Filter Ground).
Note: Detail information about the connectors on www.wst.com.tw
DC Output Connector (CN2):
Pin# Terminal Mating Housing
1, 2 V+
WST I39606PS-2 WST P4-I39606
or equivalent or equivalent
3, 4 V-
RAC48/OF
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
PA-54 www.recom-power.comREV: 3/2017
Input Voltage vs Load
Output Power [%]
100
60
20
40
Input Voltage [VAC]
0
80
110 115 23090 264

RAC48-05S/OF

Mfr. #:
Manufacturer:
RECOM Power
Description:
Switching Power Supplies 40W 5V 0-8A 90-264Vin 2X4 Open
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet