Specifications
(typical at 25°C and 230VAC)
Package Style and Pinning
AC Input Connector (CN1):
Pin# Terminal Mating Housing
1 AC/N
WST I39606PS-2 WST P3-I39606
or equivalent or equivalent
2 AC/L
Operating Temperature Range Full Load without derating -20°C to +50°C
with derating -20°C to +70°C
Storage Temperature Range -40°C to +80°C
Operation Humidity non-condensing 20% - 90% RH
Storage Humidity 10% - 90% RH
Vibration 10-500Hz, 2G, 10 Min. along X, Y and Z
Weight 145g
Dimensions (LxWxH) 101.6 x 50.8 x 30mm
Package Quantity 30pcs / carton
Package Dimensions Carton (LxWxH) 325 x 270 x 220mm
MTBF (using MIL-HDBK-217F, 25°C) >450 x 10³ hours
Certifications:
General Safety Report: E196683 UL-60950-1 2nd
IEC/EN General Safety Report: PSE103-0658 IEC/EN-60950-1 2nd
EMC Conducted and Radiated Report: HA080035-SCCE EN55022, Class B
Immunity Report: HA080035-SCCE EN55024
Report: HA080035-SBFD FCC, Part 15, Class B
Harmonics Report: HA080035-SCCE EN61000-3-2
EN61000-3-3
EN61000-4-2, 3, 4, 5, 6, 8, 11, Critertia A
Emission Report: HA080035-SCCE EN61000-6-3
ErP complies to European Directive for Energy Related Products 2004/125/EC
Notes
Note1: Mounting holes A, B must be grounded for EMI (Filter Ground).
Note: Detail information about the connectors on www.wst.com.tw
DC Output Connector (CN2):
Pin# Terminal Mating Housing
1, 2 V+
WST I39606PS-2 WST P4-I39606
or equivalent or equivalent
3, 4 V-
RAC48/OF
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
PA-54 www.recom-power.comREV: 3/2017
Input Voltage vs Load