210
2016-01
Air performance measured according to: ISO 5801.
Installation category A, without contact protection.
Noise: Total sound power level L
W
A ISO 103002
measured on a hemisphere with a radius of 2 m.
Sound pressure level L
p
A measured at 1 m distance
from fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
– Possible special versions:
(See page 12)
- Moisture protection
Max. 135 m
3
/h
Type m
3
/h cfm VAC Hz dB(A) Bel(A) / Watts rpm
-1
°C Hours Hours
9956 L 84 49.4 230 50 29 4.4 9.5 1850 -40...+80 57 500 / 22 500 ¿
9956 M 104 61.2 230 50 35 4.7 10.0 2250 -40...+80 57 500 / 22 500 ¡
9950 117 68.9 230 50 37 5.0 14.0 2450 -20...+70 47 500 / 22 500 ¬
9956 117 68.9 230 50 37 5.0 14.0 2450 -40...+70 47 500 / 22 500 ¬
9906 L 100 58.9 115 60 34 4.6 8.0 2100 -40...+80 62 500 / 25 000 √
9906 M 111 65.3 115 60 37 5.0 8.0 2450 -40...+80 62 500 / 25 000 ƒ
9900 135 79.5 115 60 42 5.4 12.0 2850 -20...+70 52 500 / 25 000 ≈
9906 135 79.5 115 60 42 5.4 12.0 2850 -40...+70 52 500 / 25 000 ≈
Subject to change
– Material: Housing: Die-cast aluminum
Impeller: Mineral-reinforced
PA plastic
– Direction of air flow: Exhaust over struts
– Direction of rotation: Counterclockwise,
looking towards rotor
– Connection: Via 2 flat plugs 2.8 x 0.5 mm
grounding lug for M4
– Weight: 320 g
– Note:
Please note our new ACmaxx series.
With identical mounting dimensions and voltages, this
series achieves greater energy efficiency.
See page 192.
Nominal voltage
Air flow
Air flow
Frequency
Sintec sleeve bearings
Ball bearings
Power consumption
Nominal speed
Temperature range
Service life L
10
at 40 °C
at T
max
Curve
Sound pressure level
Sound power level
Finger guards
from p. 242
Cables
P. 255
AC axial fans
119 x 25 mm
Series 9900
Nominal data