Z02205
Modem Controller
ZiLOG
6 PS001000-MOD0599
IIR
Reset Input
Current
5.5V –20 –180 –85 µA
I
CC
Supply Current 5.5V 25 20 mA @ 16 MHz 4
I
CC1
Standby Current
(HALT Mode)
5.5V 8 3.7 mA V
IN
= 0V, V
CC
@ 16 MHz
4
I
CC2
Standby Current
(STOP Mode)
5.5V 10 4 µA V
IN
= 0V, V
CC
WDT is
not Running
6,11
5.5V 800 600 µA V
IN
= 0V, V
CC
WDT is
Running
6,11,
13
V
ICR
Input Common
Mode
Voltage Range
5.5V 0 V
CC
–1.0V V 10
I
ALL
Auto Latch Low
Current
5.5V 1.4 15 5 µA 0V < V
IN
< V
CC
9
I
ALH
Auto Latch High
Current
5.5V –1.0 –8 –6 µA 0V < V
IN
< V
CC
9
V
LV
V
CC
Low
Voltage
Protection
Voltage
2.8 V 4 MHz max Int. CLK
Freq.
7
2.2 3.1 2.8 6 MHz max Int. CLK
Freq.
7,13
V
OH
Output High
Voltage
(Low EMI
Mode)
5.0V V
CC
–0.4 4.8 V I
OH
= –0.5 mA
V
OL
Output Low
Voltage
(Low EMI
Mode)
5.0V 0.4 0.1 V I
OL
= 1.0 mA
Notes:
1. Typicals at V
CC
= 5.0V.
2. GND = 0V.
3. The V
DD
voltage specification of 5.5V guarantees 5.0V ±0.5V with typicals at V
CC
–5.0V.
4. All outputs unloaded, I/O pins floating, inputs at rail.
5. CL1 = CL2 = 10 pF.
6. Same as note [4] except inputs at V
CC
.
7. The V
LV
voltage increases as the temperature decreases and will overlap lower V
CC
operating region.
8. Standard Mode (not Low EMI).
9. Auto Latch (Mask Option) selected.
10. For analog comparator, inputs when analog comparators are enabled.
11. Clock must be forced Low, when XTAL1 is clock-driven and XTAL2 is floating.
12. Excludes clock pins.
13. 0°C to 70°C (standard temperature).
V
CC
T
A
= 0° C to +70°C
Sym Parameter Note [3]
Min Max
Typical [1]
@ 25°C Units Conditions Notes