TK
3
ds_61018_0000_en_tk: 110509J
3) 2 coil latching
*Pulse drive (JIS C 5442-1986)
2. Specifications
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load. (SX relays are available for low level load switching [10V DC, 10mA max. level])
*2 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (p. 19, Relay Technical Information).
*3 The maximum ambient temperature allows for coil temperature rise at maximum allowable coil voltage.
As for the applicable range of continuous carrying current against temperature, please refer to “Maximum value of continuous carrying current” chart. (Page 4)
Nominal coil
voltage
Set voltage
(at 20°C 68°F)
Reset voltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
Set coil Reset coil Set coil Reset coil Set coil Reset coil
1.5V DC
75%V or less of
nominal voltage*
(Initial)
75%V or less of
nominal voltage*
(Initial)
133.9mA 133.9mA 11.2Ω 11.2Ω
200mW 200mW
150%V of
nominal voltage
3V DC 66.7mA 66.7mA 45Ω 45Ω
4.5V DC 44.5mA 44.5mA 101.2Ω 101.2Ω
5V DC 40mA 40mA 125Ω 125Ω
6V DC 33.3mA 33.3mA 180Ω 180Ω
9V DC 22.2mA 22.2mA 405Ω 405Ω
12V DC 20.8mA 20.8mA 576Ω 576Ω 250mW 250mW
120%V of
nominal voltage
24V DC 16.7mA 16.7mA 1,440Ω 1,440Ω 400mW 400mW
110%V of
nominal voltage
Characteristics Item Specifications
Contact
Arrangement 1 Form C
Initial contact resistance, max. Max. 50 mΩ (By voltage drop 6 V DC 1A)
Contact material Ag+Au clad
Rating
Nominal switching capacity 2 A 30 V DC (resistive load)
Max. switching power 60 W (DC) (resistive load)
Max. switching voltage 220 V DC
Max. switching current 2 A
Min. switching capacity (Reference value)*
1
10μA 10mV DC
Nominal operating
power
Single side stable 140 mW (1.5 to 12 V DC), 270 mW (24 V DC)
1 coil latching 100 mW (1.5 to 12 V DC), 150 mW (24 V DC)
2 coil latching 200 mW (1.5 to 9 V DC), 250 mW (12 V DC), 400 mW (24 V DC)
Electrical
characteristics
Insulation resistance (Initial)
Min. 1,000MΩ (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 750 Vrms for 1 min. (Detection current: 10 mA)
Between contact and coil 1,500 Vrms for 1 min. (Detection current: 10 mA)
Surge breakdown
voltage (Initial)
Between open contacts 1,500 V (10×160μs) (FCC Part 68)
Between contacts and coil 2,500 V (2×10μs) (Telcordia)
Temperature rise (at 20°C 68°F)
Max. 50°C
(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 2A.)
Operate time [Set time] (at 20°C 68°F)
Max. 3 ms [Max. 3 ms] (Nominal coil voltage applied to the coil, excluding contact bounce
time.)
Release time [Reset time] (at 20°C 68°F)
Max. 2 ms [Max. 3 ms] (Nominal coil voltage applied to the coil, excluding contact bounce
time.) (without diode)
Mechanical
characteristics
Shock resistance
Functional Min. 750 m/s
2
(Half-wave pulse of sine wave: 6 ms; detection time: 10μs.)
Destructive Min. 1,000 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
Vibration resistance
Functional 10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10μs.)
Destructive 10 to 55 Hz at double amplitude of 5 mm
Expected life
Mechanical Min. 10
8
(Single side stable), Min. 5×10
7
(1 or 2 coil latching) (at 180 cpm)
Electrical Min. 10
5
(2 A 30 V DC resistive) (at 20 cpm)
Conditions
Conditions for operation, transport and storage*
2
Ambient temperature: –40°C to 85°C –40°F to 185°F*
3
;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed (at rated load) 20 cpm
Unit weight Approx. 1 g .035 oz.