CF2-12V

CF
SPECIFICATIONS
TYPES AND COIL DATA (at 20°C 68°F)
* Other pick-up voltage types are also available. Please contact us for details.
TWIN POWER
AUTOMOTIVE RELAY
CF RELAYS
Part No.
Nominal voltage,
V DC
Pick-up voltage,
V DC
(Initial)
Drop-out
voltage,
V DC (Initial)
Coil resistance,
Nominal operating
current,
mA
Nominal
operating Power,
mW
Usable voltage
range,
VDC
CF2-12V 12 Max. 7.2 Min. 1.0 225±10% 53.3±10% 640 10 to 16
FEATURES
7 Amp Steady/30 Amp Inrush current
capability
Simple footprint enables ease of PC
board layout
16.5
.650
16.5
.650
22.5
.886
mm inch
RoHS Directive compatibility information
http://www.nais-e.com/
Normally
Open
Open
Space
Common
Normally
Closed
Coil 1
Coil 2
Contact
Coil
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load.
Characteristics
Remarks
*
1
Measurement at same location as Initial breakdown voltage section
*
2
Detection current: 10mA
*
3
Excluding contact bounce time
*
4
Half-wave pulse of sine wave: 11ms; detection time: 10µs
*
5
Half-wave pulse of sine wave: 6ms
*
6
Detection time: 10µs
*
7
Time of vibration for each direction;
X, Y, direction: 2 hours
Z direction: 4 hours
*
8
Refer to Conditions for operation, transport and storage mentioned in AMBIENT
ENVIRONMENT.
Please inquire if you will be using the relay in a high temperature atmosphere
(110°C 230°F).
Arrangement 1 Form C×2 (H bridge)
Contact material Ag alloy (Cadmium free)
Initial contact resistance (Initial)
(By voltage drop 6 V DC 1 A)
Typ. 6 m (N.O.)
Typ. 9 m (N.C.)
Initial contact voltage drop Max. 0.2 V (at 20 A)
Rating
Nominal switching
capacity
N.O.: 20A 14 V DC
N.C.: 10A 14 V DC
Max. carrying current
30 A (2 minutes), 20 A (1 hour)
(coil applied voltage:
12 V, at 20°C)
25 A (2 minutes), 15 A (1 hour)
(coil applied voltage:
12 V, at 85°C)
Min. switching capacity
#1
1 A 12 V DC
Expected
life (min.
ope.)
Mechanical (at 120 cpm) 10
6
Electrical
resistive load Min.10
5
7 A 14 V DC,
Inrush 30 A
(Motor load)
2×10
5
20 A 14 V DC
(Motor lock)
Min.5×10
4
Nominal operating power 640 mW
Max. operating speed (at rated load) 120 cpm
Initial insulation resistance*
1
Min. 100 M (at 500 V DC)
Initial
breakdown
voltage*
2
Between open contacts 1,000 Vrms for 1 min.
Between contacts and coil 1,000 Vrms for 1 min.
Operate time*
3
(at nominal voltage) Max. 10 ms (initial)
Release time*
3
(at nominal voltage) Max. 10 ms (initial)
Shock resistance
Functional*
4
Min. 100 m/s
2
{10 G}
Destructive*
5
Min. 1,000 m/s
2
{100 G}
Vibration resistance
Functional*
6
Approx. 44.1 m/s2 {4.5 G},
10 Hz to 100 Hz
Destructive*
7
Approx. 44.1 m/s
2
{4.5 G},
10 Hz to 500 Hz
Conditions for operation,
transport and storage*
8
(Not freezing and
condensing at low
temperature)
Ambient temp.
40°C to + 85°C
40°F to +185°F
Humidity 5%R.H. to 85%R.H.
Mass Standard type Approx. 15 g .529 oz
X
Y
Z
TYPICAL APPLICATIONS
Power windows
Auto door lock
Electrically powered sunroof
Electrically powered mirrors
Powered seats
Lift gates
Slide door closers, etc.
(for DC motor forward/
reverse control circuits)
ORDERING INFORMATION
Contact arrangement Coil voltage(DC)
1 Form C × 2
Standard packing: Carton: 35pcs.; Case: 700pcs.
12 V
Ex. CF 2 12 V
All Rights Reserved
© COPYRIGHT Matsushita Electric Works, Ltd.
Order Discontinued as of October 31, 2009
CF
EXAMPLE OF CIRCUITS
REFERENCE DATA
DIMENSIONS
mm inch
3.81
.150
0.3
.012
0.3
.012
1.0
.039
1.0
.039
1.0
.039
1.0
.039
1.0
.039
0.2
.008
0.25
.010
0.25
.010
7.62
.300
10.16
.400
JAPAN
Pre-soldering
*A
Max. 1.2
.047
16.5
.650
3.5
.138
12.7
.500
5.08
.200
5.08
.200
2.54
.100
Recommended PC board pattern
Schematic
Land diameter
(0.8)
(.031)
(3)
(.118)
(6-4 dia.)
(6-.157 dia.)
(R1.5)
7.62±0.1
.300±.004
10.16±0.1
.400±.004
6.35±0.1
.250±.004
12.7±0.1
.500±.004
4-1.5 dia.±0.1
4-.059 dia.±.004
4-1.3 dia.±0.1
4-.052 dia.±.004
5.08±0.1
.200±.004
1.27±0.1
.050±.004
2.54±0.1
.100±.004
5.08±0.1
.200±.004
3.81±0.1
.150±.004
NC
NO
COM1
COM2
Dimension: General tolerance
Max. 1mm .039 inch: ±0.1 ±.004
1 to 3mm .039 to .118 inch: ±0.2 ±.008
Min. 3mm .118 inch: ±0.3 ±.012
* Dimensions (thickness and width) of terminal specied in this catalog is measured before pre-soldering.
Intervals between terminals is measured at A surface level.
Forward/reverse control circuits of DC motor for power window
: Power window motor
12 V DC
SW A
M
M
SW B
NO NO
NCNC
COM COM
SW A SW B Motor
OFF OFF Stop
ON OFF Forward
OFF ON Reverse
1-(1). Coil temperature rise (at room
temperature)
Sample: CF2-12V, 6pcs.
Measured potion: Inside the coil
Contact carrying current: 10A, 15A, 20A
Ambient temperature: Room temperature
1-(2). Coil temperature rise (at 85°C 185°F)
Sample: CF2-12V, 6pcs.
Measured potion: Inside the coil
Contact carrying current: 10A, 15A, 20A
Ambient temperature: 85°C 185°F
2. Max. switching capability (Resistive load,
initial)
0
20
40
60
80
100
12 14 16
Coil applied voltage, V
Temperature rise, °C
20A
15A
10A
0
20
40
60
80
100
12 14 16
Coil applied voltage, V
Temperature rise, °C
15A
20A
10A
0
Switching current, A
Switching voltage, VDC
10
50
40
30
20
60
020304010 50
(N.O. side Room temperature)
3. Ambient temperature and operating
temperature range
4. Distribution of pick-up and drop-out voltage
Sample: CF2-12V, 100pcs.
5. Distribution of operate and release time
Sample: CF2-12V, 100pcs.
* With diode
0
Ambient temperature, °C
Coil applied voltage, VDC
5
10
15
35
30
25
20
40
40 20 20 40 60 1000 120
8085
Pick-up voltage
(Cold start)
0
30
20
10
40
50
60
70
Voltage, V
Frequency
1.5 2.0 2.5 3.0 3.5 4.5 5.04.0 5.5 6.0 6.5
Pick-up voltage
Drop-out voltage
0
30
20
10
40
50
60
Operate and release time, ms
Frequency
3.0 3.5 4.5 5.04.0 5.5 6.0 7.0 7.5 8.06.5
Operate time
Release time
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
Order Discontinued as of October 31, 2009
CF
For Cautions for Use, see Relay Technical Information.
6-(1). Electrical life test (Motor free)
Sample: CF2-12V, 3pcs.
Load: Inrush current: 30A, Steady current: 7A,
Power window motor actual load (free condition)
Switching frequency: (ON:OFF = 1s:5s)
Ambient temperature: Room temperature
Circuit
Change of pick-up and drop-out voltage Change of contact resistance
Relay 1
Relay 2
1s
3s
1s
6s (1 cycle)
M
Resistive
load
Power window
motor (free)
0
No. of operations, × 10
4
Pick-up and drop-out voltage, V
Max.
Max.
Min.
Min.
X
X
2
1
4
6
8
9
7
5
3
10
01015520
Pick-up voltage
Drop-out voltage
0
No. of operations, × 10
4
Contact resistance, m
Max.
Min.
X
10
20
30
40
50
01020
Load current waveform
Inrush current: 27A, Steady current: 8.4A
Brake current: 15A
200ms
10A
6-(2). Electrical life test (Motor lock)
Sample: CF2-12V, 3pcs.
Load: 20A 14V DC,
Power window motor actual load (lock condition)
Switching frequency: (ON:OFF = 1s:5s)
Ambient temperature: Room temperature
Circuit
Change of pick-up and drop-out voltage Change of contact resistance
Relay 1
Relay 2
1s
3s
1s
6s (1 cycle)
M
Power window
motor (lock)
0
No. of operations, × 10
4
Pick-up and drop-out voltage, V
Max.
Max.
Min.
Min.
2
1
4
6
8
9
7
5
3
10
05
Pick-up voltage
Drop-out voltage
X
X
0
No. of operations, × 10
4
Contact resistance, m
Max.
Min.
10
20
30
40
50
052.5
X
Load current waveform
200ms
5A
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
Order Discontinued as of October 31, 2009

CF2-12V

Mfr. #:
Manufacturer:
Panasonic Industrial Devices
Description:
Automotive Relays 30A 12VDC 1 FORM C X 2
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet