cui.com
CUI Inc │ SERIES: PRF20 │ DESCRIPTION: DC-DC CONVERTER date 02/12/2014 │ page 2 of 6
INPUT
parameter conditions/description min typ max units
operating input voltage 43 110 160 Vdc
under voltage shutdown
power up
power down
40
38
Vdc
Vdc
surge voltage for maximum of 100 ms 200 Vdc
start-up time
single output models
dual output models
15
25
ms
ms
CTRL
1
positive logic
models ON (open or 3.5~75 Vdc)
models OFF (0~1.2 Vdc)
negative logic
models ON (0~1.2 Vdc)
models OFF (open or 3.5~75 Vdc)
fi lter pi fi lter
Note: 1. Open collector refer to -Vin.
OUTPUT
parameter conditions/description min typ max units
maximum capacitive load
5V output model
12V output model
15V output model
±12V output model
±15V output model
5600
1000
1000
±680
±350
μF
μF
μF
μF
μF
line regulation from high line to low line ±0.2 %
load regulation
from full load to no load
single output models
dual output models
±0.5
±1
%
%
cross regulation dual output models, load cross variation 10%/100% ±5 %
voltage accuracy ±1.5 %
adjustability
2
±10 %
switching frequency 250 KHz
transient response 25% load step change 250 μs
temperature coeffi cient ±0.03 %/°C
Note: 2. Output trimming available on single output models only
PROTECTIONS
parameter conditions/description min typ max units
short circuit protection continuous
over current protection 110 160 %
over voltage protection
protected by internal zener or TVS clamp
5V output model
12V output model
15V output model
±12V output model
±15V output model
6.2
15
18
±15
±18
Vdc
Vdc
Vdc
Vdc
Vdc
SAFETY AND COMPLIANCE
parameter conditions/description min typ max units
isolation voltage input to output for 1 minute 2,250 Vdc
isolation resistance 1000 MΩ
safety approvals UL60950-1
EMI/EMC EN55022 class A, EN50155 (external circuit required)
RoHS 2011/65/EU
For more information, please visit the product page.