PS9505,PS9505L1,PS9505L2,PS9505L3 Chapter Title
R08DS0015EJ0100 Rev.1.00 Page 6 of 20
Jan 06, 2012
RECOMMENDED OPERATING CONDITIONS
Parameter Symbol MIN. TYP. MAX. Unit
Supply Voltage (VCC - VEE) 15 30 V
Forward Current (ON) IF (ON) 7 10 16 mA
Forward Voltage (OFF) VF (OFF) −2 0.8 V
Operating Ambient Temperature TA −40 110 °C
ELECTRICAL CHARACTERISTICS
(V
EE = GND, unless otherwise specified and refer to RECOMMENDED OPERATING CONDITIONS)
Parameter Symbol Conditions MIN. TYP.
*1
MAX. Unit
Diode Forward Voltage VF IF = 10 mA, TA = 25°C 1.2 1.56 1.8 V
Reverse Current IR VR = 3 V, TA = 25°C 10
μ
A
Input Capacitance CIN f = 1 MHz, VF = 0 V, TA = 25°C 30 pF
Detector High Level Output Current IOH VO = (VCC − 4 V)
*2
0.5 2.0 A
VO = (VCC − 15 V)
*3
2.0
Low Level Output Current IOL VO = (VEE + 2.5 V)
*2
0.5 2.0 A
VO = (VEE + 15 V)
*3
2.0
High Level Output Voltage VOH IO = −100 mA
*4
VCC − 3.0 VCC − 1.5 V
Low Level Output Voltage VOL IO = 100 mA 0.1 0.5 V
High Level Supply Current ICCH VO = open, IF = 10 mA 1.4 3.0 mA
Low Level Supply Current ICCL VO = open, VF = 0 to +0.8 V 1.3 3.0 mA
UVLO Threshold VUVLO+ VO > 5 V, IF = 10 mA 10.8 12.3 13.4 V
VUVLO− 9.5 11.0 12.5
UVLO Hysteresis UVLOHYS VO > 5 V, IF = 10 mA 0.4 1.3 V
Coupled Threshold Input Current
(L → H)
IFLH IO = 0 mA, VO > 5 V 2.0 5.0 mA
Threshold Input Voltage
(H → L)
VFHL IO = 0 mA, VO < 5 V 0.8 V
*1 Typical values at T
A = 25°C.
*2 Maximum pulse width = 50
μ
s, Maximum duty cycle = 0.5%.
*3 Maximum pulse width = 10
μ
s, Maximum duty cycle = 0.2%
*4 V
OH is measured with the DC load current in this testing (Maximum pulse width = 2 ms, Maximum duty cycle =
20%).
<R>