PS8601,PS8601L
ELECTRICAL CHARACTERISTICS (TA = 25 °C)
Parameter Symbol Conditions MIN. TYP.
*1
MAX. Unit
Diode Forward Voltage VF IF = 16 mA 1.7 2.2 V
Reverse Current IR VR = 5 V 10
µ
A
Forward Voltage
Temperature Coefficent
∆
VF/
∆
T IF = 16 mA −1.6 mV/°C
Terminal Capacitance Ct V = 0 V, f = 1 MHz 60 pF
Detector High Level Output Current IOH(1) IF = 0 mA, VCC = VO = 5.5 V 3 500 nA
High Level Output Current IOH(2) IF = 0 mA, VCC = VO = 35 V 100
µ
A
Low Level Output Voltage VOL IF = 16 mA, VCC = 4.5 V, IO = 1.2 mA 0.1 0.4 V
Low Level Supply Current ICCL IF = 16 mA, VO = Open, VCC = 35 V 50
µ
A
High Level Supply Current ICCH IF = 0 mA, VO = Open, VCC = 35 V 0.01 1
µ
A
DC Current Gain hFE VO = 5 V, IO = 3 mA 100
Coupled Current Transfer Ratio CTR IF = 16 mA, VCC = 4.5 V, VO = 0.4 V 15 %
Isolation Resistance RI-O VI-O = 1 kVDC 10
11
Ω
Isolation Capacitance CI-O V = 0 V, f = 1 MHz 0.7 pF
Propagation Delay Time tPHL IF = 16 mA, VCC = 5 V, RL = 1.9 kΩ 0.5 0.8
µ
s
(H → L)
*2
Propagation Delay Time tPLH IF = 16 mA, VCC = 5 V, RL = 1.9 kΩ 0.3 0.8
µ
s
(L → H)
*2
*1 Typical values at T
A = 25 °C
*2 Test circuit for propagation delay time
18
27
36
45
I
F
51 Ω
V
CC
= 5 V
(Monitor)
V
O
R
L
C
L
= 15 pF
C
L
includes probe and stray wiring capacitance
0.1
F
µ
Input
Output
Pulse Input
I
F
Monitor
PW = 100 s
Duty Cycle = 1/10
µ
(
)
50 %
1.5 V
5 V
V
OL
t
PHL
t
PLH
USAGE CAUTIONS
1. This product is weak for static electricity by designed with high-speed integrated circuit so protect against static
electricity when handling.
2. By-pass capacitor of more than 0.1
µ
F is used between VCC and GND near device. Also, ensure that the
distance between the leads of the photocoupler and capacitor is no more than 10 mm.
3. Avoid storage at a high temperature and high humidity.
Data Sheet PN10262EJ01V0DS