2 Ultra-thin Low Signal Relay G6L
Specifications
■ Contact Ratings
■ Coil Ratings
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil.
■ Characteristics
Note: 1. The contact resistance was measured with 10 mA at 1 VDC with a fall-of-potential method.
2. Values in parentheses are actual values.
3. The insulation resistance was measured with a 500-VDC Megger Tester applied to the same parts as those used for checking the dielec-
tric strength.
4. This value was measured at a switching frequency of 120 operations/min. This value may vary, depending on switching frequency, oper-
ating conditions, expected reliability level of the relay, etc. It is always recommended to double-check relay suitability under actual load
conditions.
5. The above values are initial values.
Item Resistive load
Contact mechanism Single crossbar
Rated load 0.3 A at 125 VAC, 1 A at 24 VDC
Carry current 1 A
Max. operating voltage 125 VAC, 60 VDC
Max. operating current 1 A
Item Voltage Rating
Rated voltage 3 VDC 4.5 VDC 5 VDC 12 VDC 24 VDC
Rated current 60.0 mA 40.0 mA 36.0 mA 15.0 mA 9.6 mA
Coil resistance 50.0 Ω 112.5 Ω 139.0 Ω 800.0 Ω 2,504.0 Ω
Pick-up voltage 75% max. of rated voltage
Dropout voltage 10% min. of rated voltage
Maximum voltage 150% of rated voltage 130% of rated
voltage
Power consumption Approx. 180 mW Approx. 230 mW
Item Non-latching Relays
G6L-1P, G6L-1F
Contact resistance (See Note 1) 100 mΩ max.
Operate time (See Note 2) 5 ms max. (approx. 1.1 ms)
Release time (See Note 2) 5 ms max. (approx. 0.4 ms)
Insulation resistance (See Note 3) 1,000 MΩ min. (at 500 VDC)
Dielectric strength Coil and contacts 1,000 VAC, 50/60 Hz for 1 min
Contacts of same
poles
750 VAC, 50/60 Hz for 1 min
Surge withstand
voltage
Coil and contacts 1,500 VAC, 10 × 160 µs
Vibration Mechanical durability 10 to 55 Hz, 1.65-mm single amplitude (3.3-mm double amplitude)
Malfunction durability 10 to 55 Hz, 1.65-mm single amplitude (3.3-mm double amplitude)
Shock Mechanical durability
1,000 m/s
2
Malfunction durability
100 m/s
2
Service life Mechanical 5,000,000 operations min. (at 36,000 operations/hour)
Electrical 100,000 operations min. (with a rated load at 1,800 operations/hour)
Failure rate (P level) (See Note 4) 1 mA at 5 VDC
Ambient temperature Operating: -40°C to 70°C (with no icing or condensation)
Humidity Operating: 5% to 85% RH
Weight Approx. 0.6 g