G6L-1F-DC24

Ultra-thin Low Signal Relay G6L 1
Ultra-thin Low Signal Relay
G6L
Extremely Thin SPST-NO Flat Relay, One
of the Thinnest Relays in the World
• For high-density mounting and slim finished packaging,
G6L uses 20% less mounting area and 67% less volume in
comparison with the G5V-1 relay.
• Measures just 7.0 (W) x 10.6 (L) x 4.2 (H) mm for surface-
mount or 3.8 (H) for through-hole.
• High dielectric strength: 1,000 VAC between coil and
contacts and 750 VAC between contacts of the same
polarity.
• Conforms to FCC Part 68 impulse withstand voltage rating
of 1.5kV for 10 x 160 µs.
• Conforms to UL60950 (File No. E41515) / CSA C22.2 No.
60950 (File No. LR31928).
• Use of lead completely eliminated.
Ordering Information
Note: 1. When ordering, add the rated coil voltage to the model number.
Example: G6L-1P 12 VDC
2. When ordering tape packing, add "-TR" to the model number.
Example: G6L-1F-TR 12 VDC
Be sure since "-TR" is not part of the relay model number, it is not marked on the relay case.
Model Number Legend:
1. Relay function
None: Non-latching
2. Contact form
1: SPST-NO
3. Terminal shape
P: PCB terminals
F: Surface-mount terminals
4. Packaging
None: Tube packaging
TR: Tape and reel packaging
Application Examples
Peripherals of MODEM/PC
Telephones
Office automation machines
Audio-visual products
Communications equipment
Measurement devices
Amusement equipment
Security equipment
Contact form Construction Mounting type Model
SPST-NO Fully sealed Through-hole terminal G6L-1P
Surface-mount terminal G6L-1F
Rated coil voltage
Tape packing
G6L -1 -
1 2 3 4
2 Ultra-thin Low Signal Relay G6L
Specifications
Contact Ratings
Coil Ratings
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil.
Characteristics
Note: 1. The contact resistance was measured with 10 mA at 1 VDC with a fall-of-potential method.
2. Values in parentheses are actual values.
3. The insulation resistance was measured with a 500-VDC Megger Tester applied to the same parts as those used for checking the dielec-
tric strength.
4. This value was measured at a switching frequency of 120 operations/min. This value may vary, depending on switching frequency, oper-
ating conditions, expected reliability level of the relay, etc. It is always recommended to double-check relay suitability under actual load
conditions.
5. The above values are initial values.
Item Resistive load
Contact mechanism Single crossbar
Rated load 0.3 A at 125 VAC, 1 A at 24 VDC
Carry current 1 A
Max. operating voltage 125 VAC, 60 VDC
Max. operating current 1 A
Item Voltage Rating
Rated voltage 3 VDC 4.5 VDC 5 VDC 12 VDC 24 VDC
Rated current 60.0 mA 40.0 mA 36.0 mA 15.0 mA 9.6 mA
Coil resistance 50.0 112.5 139.0 800.0 2,504.0
Pick-up voltage 75% max. of rated voltage
Dropout voltage 10% min. of rated voltage
Maximum voltage 150% of rated voltage 130% of rated
voltage
Power consumption Approx. 180 mW Approx. 230 mW
Item Non-latching Relays
G6L-1P, G6L-1F
Contact resistance (See Note 1) 100 m max.
Operate time (See Note 2) 5 ms max. (approx. 1.1 ms)
Release time (See Note 2) 5 ms max. (approx. 0.4 ms)
Insulation resistance (See Note 3) 1,000 M min. (at 500 VDC)
Dielectric strength Coil and contacts 1,000 VAC, 50/60 Hz for 1 min
Contacts of same
poles
750 VAC, 50/60 Hz for 1 min
Surge withstand
voltage
Coil and contacts 1,500 VAC, 10 × 160 µs
Vibration Mechanical durability 10 to 55 Hz, 1.65-mm single amplitude (3.3-mm double amplitude)
Malfunction durability 10 to 55 Hz, 1.65-mm single amplitude (3.3-mm double amplitude)
Shock Mechanical durability
1,000 m/s
2
Malfunction durability
100 m/s
2
Service life Mechanical 5,000,000 operations min. (at 36,000 operations/hour)
Electrical 100,000 operations min. (with a rated load at 1,800 operations/hour)
Failure rate (P level) (See Note 4) 1 mA at 5 VDC
Ambient temperature Operating: -40°C to 70°C (with no icing or condensation)
Humidity Operating: 5% to 85% RH
Weight Approx. 0.6 g
Ultra-thin Low Signal Relay G6L 3
Engineering Data
10
10
7
5
3
1
0.7
0.5
0.3
0.1
30 50 70 100 300 500 700
1,000
DC resistive load
AC resistive load
Switching voltage (V)
Switching current (A)
250
200
150
100
50
0
3 to 12 VDC
20 0 20 40 60 80
40
Ambient temperature (˚C)
24 VDC
Maximum voltage (%)
1.2
1
0.8
0.6
0.4
0.2
0
20 0 20 40 60 80
40
Ambient temperature (˚C)
Switching current (A)
Maximum Switching Capacity Ambient Temperature vs.
Maximum Voltage
Ambient Temperature vs.
Switching Current
1,000
500
300
100
50
30
10
5
3
1
Switching current (A)
0 0.2 0.4 0.6 0.8 1 1.2
24-VDC resistive load
125-VAC resistive load
Switching operations (×10
4
operations)
Max. estimated value
max.
avg.
min.
max.
avg.
min.
100
90
80
70
60
50
40
30
20
10
0
Ambient temperature (˚C)
60
40
20 0 20 40 60 80
Must operate voltage
Must release voltage
On the basis of rated voltage (%)
Z
Z'
Y
Y'
X
X'
200
400
600
800
1,000
1,000
1,0001,000
1,000
800
600
400
200
1,000
Unit: m/s
2
Sample: G6L-1F
Number of Relays: 10
Energized
Shock direction
X
X'
Z
Z'
Y
Y'
Endurance Ambient Temperature vs. Must
Operate or Must Release Voltage
Shock Malfunction
Conditions: Shock is applied in ±X, ±Y, and ±Z
directions three times each with and without energizing
the Relays to check the number of contact
malfunctions.
Must operate voltage
max.
min.
max.
min.
Must release voltage
0.1
1 10 100 1,000
Operating frequency (×10
3
operations)
100
80
60
40
20
0
Sample: G6L-1F
Number of Relays: 10
Test conditions: 1-A resistive load at
24-VDC with an operation rate of 50%
Switching frequency: 1,800 operations/h
On the basis of rated voltage (%)
NO contact
max.
min.
Contact resistance
0.1
1 10 100 1,000
Operating frequency (×10
3
operations)
1,000
500
300
100
50
30
10
Sample: G6L-1F
Number of Relays: 10
Test conditions: 1-A resistive load at
24-VDC with an operation rate of 50%
Switching frequency: 1,800 operations/h
Contact resistance (m )
NO contact
max.
min.
1
10 100 1,000 10,000
Operating frequency (×10
3
operations)
1,000
500
300
100
50
30
10
Sample: G6L-1F
Number of Relays: 10
Test conditions: 1-A resistive load at
24-VDC with an operation rate of 50%
Switching frequency: 1,800 operations/h
Contact resistance (m )
Electrical Endurance (with Must
Operate and Must Release
Voltage) (See Note)
Electrical Endurance
(Contact Resistance) (See Note)
Contact Reliability Test (Contact
Resistance) (See Note)
Note: The tests were conducted at an ambient temperature of 23°C.
Note: “Maximum Voltage” is the maximum
voltage that can be applied to the relay coil.

G6L-1F-DC24

Mfr. #:
Manufacturer:
Omron Electronics
Description:
Low Signal Relays - PCB 1 AMP 24VDC SPST SMT
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union