AC05AT0003300JAC00

AC, AC-AT
www.vishay.com
Vishay Draloric
Revision: 14-Mar-17
7
Document Number: 28730
For technical questions, contact: ww1resistors@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
AC01 and AC01-AT Pulse on a regular basis; max. permissible
peak pulse voltage (
max.
) as a function of pulse duration (t
i
)
AC04 and AC04-AT Pulse on a regular basis; max. permissible
peak pulse voltage (
max.
) as a function of pulse duration (t
i
)
AC07 and AC07-AT Pulse on a regular basis; max. permissible
peak pulse voltage (
max.
) as a function of pulse duration (t
i
)
AC03 and AC03-AT Pulse on a regular basis; max. permissible
peak pulse voltage (
max.
) as a function of pulse duration (t
i
)
AC05 and AC05-AT Pulse on a regular basis; max. permissible
peak pulse voltage (
max.
) as a function of pulse duration (t
i
)
AC10 and AC10-AT Pulse on a regular basis; max. permissible
peak pulse voltage (
max.
) as a function of pulse duration (t
i
)
t
i
(s)
V
max.
(V)
ˆ
1500
0
500
10
-6
10
-5
10
-4
10
-3
10
-2
10
-1
1
1000
V
ˆ
2500
2000
1500
0
500
1000
t
i
(s)
V
max.
(V)
ˆ
10
-6
10
-5
10
-4
10
-3
10
-2
10
-1
1
V
ˆ
5000
4000
3000
0
1000
2000
t
i
(s)
V
max.
(V)
ˆ
10
-6
10
-5
10
-4
10
-3
10
-2
10
-1
1
V
ˆ
t
i
(s)
V
max.
(V)
ˆ
10
-6
10
-5
10
-4
10
-3
10
-2
10
-1
1
2000
1500
0
500
1000
2500
2000
1500
0
500
1000
t
i
(s)
V
max.
(V)
ˆ
10
-6
10
-5
10
-4
10
-3
10
-2
10
-1
1
5000
4000
3000
0
1000
2000
t
i
(s)
V
max.
(V)
ˆ
10
-6
10
-5
10
-4
10
-3
10
-2
10
-1
1
AC, AC-AT
www.vishay.com
Vishay Draloric
Revision: 14-Mar-17
8
Document Number: 28730
For technical questions, contact: ww1resistors@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
FUNCTIONAL PERFORMANCE
0
20
40
60
80
100
120
-40 50 100 150 200 250 300 350
Ambient Temperature in °C
Rated Power in %
0
40
Derating
0
100
150
200
250
300
350
010155
Temperature Rise
50
Power in W
Temperature Rise in K
AC10,
AC10-AT
AC05,
AC05-AT
AC04,
AC04-AT
AC03,
AC03-AT
AC01,
AC01-AT
AC07,
AC07-AT
AC, AC-AT
www.vishay.com
Vishay Draloric
Revision: 14-Mar-17
9
Document Number: 28730
For technical questions, contact: ww1resistors@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
TESTS PROCEDURES AND REQUIREMENTS
All tests are carried out in accordance with the following
specifications:
IEC 60115-1, generic specification (includes tests)
The test and requirements table contains only the most
important tests. For the full test schedule refer to the
documents above.
The tests are carried out in accordance with IEC 60068-2-xx
test method and under standard atmospheric conditions in
accordance with IEC 60068-1, 5.3.
Climatic category -40 / 200 / 56 (rated temperature range:
lower category temperature, upper category temperature;
damp heat, steady state, test duration: 56 days) is valid.
Unless otherwise specified the following values apply:
Temperature: 15 °C to 35 °C
Relative humidity: 45 % to 75 %
Air pressure: 86 kPa to 106 kPa (860 mbar to 1060 mbar)
For performing some of the tests, the components are
mounted on a test board in accordance with IEC 60115-1,
4.31.
In test procedures and requirements table, only the tests
and requirements are listed with reference to the relevant
clauses of IEC 60115-1 and IEC 60068-2-xx test methods.
A short description of the test procedure is also given.
TEST PROCEDURES AND REQUIREMENTS
IEC 60115-1
CLAUSE
IEC 60068-2
TEST
METHOD
TEST PROCEDURE
REQUIREMENTS
PERMISSIBLE CHANGE (R
MAX.
)
4.13 - Short time overload
Room temperature;
10x rated power P
40
;
5 s
± (2 % R + 0.1 )
4.16
21 (Ua
1
)
21 (Ub)
21 (Uc)
Robustness of
terminations
Tensile, bending and torsion
No damage
± (0.5 % R + 0.05)
4.18 20 (Tb)
Resistance to
soldering heat
Unmounted components
(260 ± 5) °C; (10 ± 1) s
± (0.5 % R + 0.05)
4.19 -
Rapid change
of temperature
30 min at -55 °C and
30 min at +200 °C;
5 cycles
± (1.5 % R + 0.05 )
4.23 Climatic sequence:
4.23.2 2 (Ba) Dry heat 16 h; 200 °C
± (1 % R + 0.05 )
4.23.3 30 (Db)
Damp heat
(accelerated)
1st cycle
24 h; 55 °C;
90 % to 100 % RH
4.23.4 1 (Aa) Cold 2 h; -55 °C
4.23.5 13 (M) Low air pressure
2 h; 8.5 kPa;
15 °C to 35 °C
4.23.6 30 (Db)
Damp heat
remaining cyclic
5 days; 55 °C;
95 % to 100 % RH; 5 cycles
4.24 78 (Cab)
Damp heat,
(steady state)
56 days; (40 ± 2) °C;
(93 ± 5) % RH
± (5 % R + 0.1 )
4.25.2 -
Endurance
(at room temperature)
1000 h;
loaded with 116 % of P
70
± (5 % R + 0.1 )
4.25.3 -
Endurance at
upper category
temperature
125 °C; without load; 1000 h ± (5 % R + 0.1 )
200 °C; 30 % of P
70
; 1000 h ± (5 % R + 0.1 )
4.35 - Flammability
IEC 60695-11-5
needle flame test; 10 s
No burning after 30 s
4.37 67 C(y)
Damp heat, steady state,
accelerated
(85 ± 2) °C; RH (85 ± 3) %;
1000 h;
10 % of operation power (P
70
)
U 0.3 x U
max.
± (5 % R + 0.1 )
4.38 - Electrostatic discharge test
2 discharges, 8 kV
(1 positive, 1 negative)
± (5 % R + 0.1 )

AC05AT0003300JAC00

Mfr. #:
Manufacturer:
Description:
Wirewound Resistors - Through Hole 5watt 330ohms 5% AEC-Q200
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union