https://www.phoenixcontact.com/us/products/1558357
11.11.2013Page2/4
Bus system cable-SAC-4P-M12MS/15,0-990-1558357
Technical data
General
Surge voltage category II
Pollution degree 3
Insertion/withdrawal cycles ≥ 100
Torque 0.4 Nm (M12 connector)
Material
Inflammability class according to UL 94 HB
Contact material CuZn
Contact surface material Ni/Au
Contact carrier material TPU GF
Material of grip body TPU, hardly inflammable, self-extinguishing
Material, knurls Zinc die-cast, nickel-plated
Sealing material NBR
Pin assignment
Position = wire color (signal) = position (optional) 1 (Plug) = SR (shield)
2 (Plug) = WH (DB)
3 (Plug) = YE (DG)
4 (Plug) = BU (DA)
Cable
Cable type CC-Link
Cable type (abbreviation) 990
Conductor cross section 0.5 mm²
AWG signal line 20
Conductor structure signal line 7x 0.28 mm
Thickness, insulation 0.89 mm (Outer cable sheath)
Wire colors white, yellow, blue
Shielding Plastic-coated aluminum foil, tinned copper braided shield
Optical shield covering 78 %
External sheath, color red
External cable diameter 7.70 mm
Smallest bending radius, fixed installation 77 mm
Cable weight 78.8 kg/km
Outer sheath, material PVC
Material conductor insulation foamed PE, with high density
Conductor material Bare Cu litz wires
Conductor resistance 31.2 Ω/km
Working capacitance 61 pF