REC30-2415D

ECO-1
REV.: 3/2017www.recom-power.com
30 Watt
2“ x 1.6“
Single and Dual
Output
DC/DC Converter
Features
Regulated
Converters
6-Side Shielding
External ON/OFF control
1.6kVDC Isolation
UL/CSA/EN-60950-1 Certified
2:1 Input Voltage Range
Continuous Short Circuit Protection
Efficiency up to 90.5%
Fixed Switching Frequency
REC30
IEC/EN60950-1 Certified
UL60950 Certified
CSA C22.2 NO. 60950 Certified
EN55022 Certified
Description
The REC30-xxxxS_D -series offer single and dual regulated outputs in a 2”x1.6” package with 1.6kVDC
isolation and are suitable for higher power industrial applications. Remote on/off control is standard.
The higher current outputs have raised output voltages to compensate for track losses as standard. The
converter is fully certified to UL/EN/IEC safety standards.
Selection Guide
Part Input Output Output Efficiency max. Capacitive
Number Voltage Range Voltage Current typ. Load
(1)
[VDC] [VDC] [mA] [%] [µF]
REC30-123.4S 9-18 3.4 6000 85 10000
REC30-125.1S 9-18 5.1 6000 87 6800
REC30-1212S 9-18 12 2500 89 1800
REC30-1215S 9-18 15 2000 88 1000
REC30-1212D 9-18 ±12 ±1250 87 ±800
REC30-1215D 9-18 ±15 ±1000 88 ±500
REC30-243.4S 18-36 3.4 6000 87 10000
REC30-245.1S 18-36 5.1 6000 89 6800
REC30-2412S 18-36 12 2500 90 1800
REC30-2415S 18-36 15 2000 89 1000
REC30-2412D 18-36 ±12 ±1250 88 ±800
REC30-2415D 18-36 ±15 ±1000 89 ±500
REC30-483.4S 36-75 3.4 6000 87.5 10000
REC30-485.1S 36-75 5.1 6000 89.5 6800
REC30-4812S 36-75 12 2500 90 1800
REC30-4815S 36-75 15 2000 90.5 1000
REC30-4812D 36-75 ±12 ±1250 89 ±800
REC30-4815D 36-75 ±15 ±1000 90.5 ±500
3
Y
E
A
R
w
a
r
r
a
n
t
y
3
Model Numbering
Single or Dual
nom. Input Voltage
Output Voltage
REC30-__ __ _
Notes:
Note1: Max. capacitive load is tested at nominal input voltage and full load.
E224736
Ordering Examples:
REC30-4812S, Single Output, 36-75Vin and 12Vout
REC30-2412D, Dual Output, 18-36Vin and ±12Vout
DC/DC Converter
ECO-2
REV.: 3/2017 www.recom-power.com
REC30
Series
BASIC CHARACTERISTICS
Parameter Condition Min. Typ. Max.
Input Voltage Range
nom. Vin= 12V
nom. Vin= 24V
nom. Vin= 48V
9VDC
18VDC
36VDC
18VDC
36VDC
75VDC
Start/up Time
10ms
Under Voltage Lockout (UVLO)
nom. Vin= 12V
DC-DC ON
DC-DC OFF
8.3VDC
7.9VDC
nom. Vin= 24V
DC-DC ON
DC-DC OFF
17.4VDC
16.7VDC
nom. Vin= 48V
DC-DC ON
DC-DC OFF
35.7VDC
34.3VDC
Output Voltage Trimming
see calculation below ±10%
CTRL ON/OFF
DC-DC ON
DC-DC OFF
Open or 3V<Vr<12V
Short or 0V<Vr<1.2V
Internal Operating Frequency
300kHz
Minimum Load 0%
Output Ripple and Noise
(2)
100mVp-p
continued on next page
Specifications (measured at T
a
= 25°C, nominal input voltage, full load and after warm up unless otherwise specified)
Notes:
Note2: Ripple and Noise is measured with a 20MHz bandwidth and a 0.1µF ceramic capacitor.
Output Voltage Trimming
Trim UP
Trim DOWN
Vref
+Vout
Trim
R1
R
down
R3
R2
Vref
-Vout
Trim
R1
R
up
R3
R2
Vref
+Vout
Trim
R1
R
down
R3
R2
Vref
-Vout
Trim
R1
R
up
R3
R2
Vout 3.4V 5.1V 12V 15V
R1
2.1 kΩ 2.55 kΩ 9.53 kΩ 9.09 kΩ
R2
1.198 kΩ 2.449 kΩ 2.498 kΩ 1.810 kΩ
R3
6.8 kΩ 9.76 kΩ 16.9 kΩ 13 kΩ
Vref
1.24 V 2.5 V
Trim Calculation
a = q
Vref
r * R1 = kΩ
(Vout + DVout) - Vref
R
up
= q
a*R2
r - R3 = kΩ
R2 - a
R
down
= q
b*R1
r - R3 = kΩ
R1 - b
b = q
(Vout + DVout) - Vref
r * R2 = kΩ
Vref
Vout = nom. output voltage
DVout = output voltage trim
R
up
= trim up resistor
R
down
= trim down resistor
a = trim up factor
b = trim down factor
DVout = Vout - Vout
trimmed
a = q
2.5V
r * 2.55kΩ = 2.043kΩ
(5.1V + 0.51V) - 2.5V
R
up
= q
2.043kΩ
* 2.449kΩ
r - 9.76 = 2.573kΩ
2.449
kΩ
- 2.043
kΩ
Trim Up:
Vout = 5.1V, DVout = 0.51V (10%), Vref= 2.5V
Trim down:
Vout = 5.1V, DVout = -0.51V (-10%), Vref= 2.5V
b = q
[5.1V + (-0.51V)] - 2.5V
r * 2.449kΩ
=
2.047kΩ
2.5V
R
down
= q
2.047kΩ * 2.55kΩ
r - 9.76kΩ = 0.627kΩ
2.55kΩ - 2.047Ω
DC/DC Converter
Specifications (measured at T
a
= 25°C, nominal input voltage, full load and after warm up unless otherwise specified)
REC30
Series
REGULATIONS
Parameter
Condition
Type
Values
Output Accuracy ±1.0% max.
Line Regulation low line to high line, full load ±0.2% max.
Load Regulation 10% to 100% load
single output
dual output
±0.5% max.
±1.0% max.
Cross Regulation 25% to 100% load dual output ±5.0% max.
Transient Response Recovery Time 25% load step change 250µS typ.
ECO-3
REV.: 3/2017www.recom-power.com
Deviation vs. Load
Efficiency vs. Load
36V
54V
75V
Efficiency [%]
Output Current [A]
0
65
75
70
85
80
90
95
100
1 2 3 4 65
18V
24V
36V
Efficiency [%]
Output Current [A]
0
65
75
70
85
80
90
95
100
1 2 3 4 65
36V
48V
75V
Deviation [%]
Output Current [A]
0
0.20
0.24
0.22
0.28
0.26
0.30
0.34
0.32
0.36
1 2 3 4 65
18V
24V
36V
Deviation [%]
Output Current [A]
0
-0.60
-0.40
-0.50
-0.20
-0.30
-0.10
0
0.10
0.20
0.1 0.2 0.3 0.4 0.5 0.6 1.00.7 0.8 0.9
REC30-485.1S
REC30-485.1S
REC30-2415D
REC30-2415D

REC30-2415D

Mfr. #:
Manufacturer:
RECOM Power
Description:
30W DC/DC-Converter 'ECONOLINE' 2 x1.6 1.6kV reg , V. In: 18-36, V. Out: +/-15, mA. Out: +/-1000
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet