Insulation and Safety Related Specications
Parameter Symbol ACPL-K30T Units Conditions
Minimum External Air Gap
(Clearance)
L(101) 8 mm Measured from input terminals to output terminals, shortest
distance through air.
Minimum External Tracking
(Creepage)
L(102) 8 mm Measured from input terminals to output terminals, shortest
distance path along body.
Minimum Internal Plastic Gap
(Internal Clearance)
0.08 mm Through insulation distance conductor to conductor, usually the
straight line distance thickness between the emitter and detector.
Tracking Resistance
(Comparative Tracking Index)
CTI 175 V DIN IEC 112/VDE 0303 Part 1
Isolation Group (DIN VDE0109) IIIa Material Group (DIN VDE 0109)
IEC/EN/DIN EN 60747-5-5 Insulation Related Characteristic (Option 060 and 560 only)
Description Symbol Option 060 and 560 Units
Installation classication per DIN VDE 0110/1.89, Table 1
for rated mains voltage < 600 V
RMS
for rated mains voltage < 1000 V
RMS
I - IV
I - III
Climatic Classication 40/125/21
Pollution Degree (DIN VDE 0110/1.89) 2
Maximum Working Insulation Voltage V
IORM
1140 V
PEAK
Input to Output Test Voltage, Method b
V
IORM
× 1.875 = V
PR
, 100% Production Test with t
m
= 1 sec
Partial Discharge < 5 pC
V
PR
2137 V
PEAK
Input to Output Test Voltage, Method a
V
IORM
× 1.6 = V
PR
, Type and sample test, t
m
= 10 sec,
Partial Discharge < 5 pC
V
PR
1824 V
PEAK
Highest Allowable Overvoltage
(Transient Overvoltage, t
ini
= 60 sec)
V
IOTM
8000 V
PEAK
Safety Limiting Values
(Maximum values allowed in the event of a failure)
Case Temperature
Input Current
Output Power
T
S
I
S,INPUT
P
S,OUTPUT
175
230
600
°C
mA
mW
Insulation Resistance at T
S
, V
IO
= 500 V R
S
>10
9
Absolute Maximum Ratings
Parameter Symbol Min. Max. Units Notes
Storage Temperature T
S
-55 150
°C
Operating Ambient Temperature T
A
-40 125
°C
Input Current Average I
F(avg)
30 mA
Surge (50% duty cycle) I
F(surge)
60 mA
Transient (1 µs pulse width, 300 pps)
I
F(trans)
1 A
Reversed Input Voltage V
R
6 V
Input Power Dissipation P
IN
60 mW
Lead Soldering
Cycle
Temperature 260
°C
Time 10 s
Solder Reow Temperature Prole Recommended reow condition as per JEDEC Standard
J-STD-020 (latest revision)
5
Recommended Operating Conditions
Parameter Symbol Min. Max. Units Note
Input Current (ON) I
F(ON)
10 20 mA
30 Pulse width < 1 s, duty cycle < 50%
Input Voltage (OFF) V
F(OFF)
0 0.8 V
Operating Temperature T
A
-40 125
°C
Electrical Specications (DC)
Unless otherwise stated, all minimum/maximum specications are over recommended operating conditions. All typical
values are at T
A
= 25 °C.
Parameter Symbol Min. Typ.
Max.
Units Test Conditions Figures Notes
Open Circuit Voltage V
OC
4.0 7 V I
F
=10 mA, I
O
= 0 mA 3, 4
4.5 I
F
=10mA, I
O
= 0 mA,
T
A
= 105 °C
4.5 7.5 I
F
= 20 mA, I
O
= 0 mA 3, 4
Temperature Coecient
of Open Circuit Voltage
ΔV
OC
/ΔT
A
-21
mV/°C
I
F
= 10 mA, I
O
= 0 mA 4
Short Circuit Current I
SC
2.0 5.0
µA
I
F
= 10 mA, V
O
= 0 V 5, 6
4.0 10.0 I
F
= 20 mA, V
O
= 0 V 5, 6
Input Forward Voltage V
F
1.25 1.55 1.85 V I
F
=10 mA
Temperature Coecient of
Forward Voltage
ΔV
F
/ΔT
A
-1.5
mV/°C
I
F
=10 mA
Input Reverse Breakdown Voltage BV
R
6 V
I
R
=10 µA
Switching Specications (AC)
Unless otherwise stated, all minimum/maximum specications are over recommended operating conditions. All typical
values are at T
A
= 25 °C.
Parameter Symbol Min. Typ. Max. Units Test Conditions Figures Notes
Turn-On Time T
ON
0.8 2.0 ms I
F
=10 mA, C
L
= 1 nF 7,10,11
0.4 1.0 I
F
=20 mA, C
L
= 1 nF 7,10,11
Turn-O Time T
OFF
0.04 0.12 ms I
F
=10 mA/20 mA, C
L
= 1 nF 8, 9,11
Package Characteristics
Unless otherwise stated, all minimum/maximum specications are over recommended operating conditions. All typical
values are at T
A
= 25 °C.
Parameter Symbol Min. Typ. Max. Units Test Conditions Figures Notes
Input-Output Momentary
Withstand Voltage*
V
ISO
5000 V
RMS
RH ≤ 50%, t = 1 minute,
T
A
= 25 °C
1, 2
Input-Output Resistance R
I-O
10
9
10
14
V
I-O
= 500 V
DC
1
Input-Output Capacitance C
I-O
0.6 pF f = 1 MHz, V
I-O
= 0 V
DC
1
* The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous
voltage rating.
Notes:
1. Device considered a two-terminal device: pins 1, 2, 3 and 4 shorted together, and pins 5, 6, 7 and 8 shorted together.
2. In accordance with UL 1577, each optocoupler is proof-tested by applying an insulation test voltage > 6000 V
RMS
for 1 second.
6
Typical Characteristic Plots and Test Conditions
Unless otherwise stated, all typical values are at T
A
= 25 °C.
4
5
6
7
8
9
10
-40 -20 0 20 40 60 80 100 120 140
Open-Circuit Voltage, V
OC
- V
Temperature, T
A
- °C
0
1
2
3
4
5
6
7
8
9
10
0 10 20 30 40 50
Input Current, I
F
- mA
Open-Circuit Voltage, V
OC
- V
0
5
10
15
20
25
0 10 20 30 40 50
Input Current, I
F
- mA
Short-Circuit Current, I
SC
- µA
0
5
10
15
20
25
30
-40 -20 0 20 40 60 80 100 120 140
Short-Circuit Current, I
SC
- µA
Temperature, T
A
- °C
0.0
0.5
1.0
1.5
2.0
2.5
-40 -20 0 20 40 60 80 100 120 140
Turn-On Time, T
ON
- ms
Temperature, T
A
- °C
0.00
0.02
0.04
0.06
0.08
0.10
0.12
0.14
0.16
-
40 -20 0 20 40 60 80 100 120 140
Turn-O Time, T
OFF
- ms
Temperature, T
A
- °C
I
F
= 5 mA
I
F
= 10 mA
I
F
= 20 mA
I
F
= 30 mA
I
F
= 50 mA
I
F
= 50 mA
I
F
= 30 mA
I
F
= 20 mA
I
F
= 10 mA
I
F
= 5 mA
I
F
= 50 mA
I
F
= 30 mA
I
F
= 20 mA
I
F
= 10 mA
I
F
= 5 mA
I
F
= 20 mA
I
F
= 30 mA
I
F
= 50 mA
I
F
= 5 mA
I
F
= 10 mA
Figure 4. Open Circuit Voltage vs. TemperatureFigure 3. Open Circuit Voltage vs. Input LED Current
Figure 7. Turn-On Time vs. Temperature Figure 8. Turn-O Time vs. Temperature
Figure 5. Short Circuit Current vs. Input LED Current Figure 6. Short Circuit Current vs. Temperature

ACPL-K30T-560E

Mfr. #:
Manufacturer:
Broadcom / Avago
Description:
Logic Output Optocouplers Auto Optocoupler IEC
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union