ST2054 Electrical ratings
5/13
3 Electrical ratings
3.1 Absolute maximum ratings
Stressing the device above the rating listed in the “Absolute Maximum Ratings” table may
cause permanent damage to the device. These are stress ratings only and operation of the
device at these or any other conditions above those indicated in the Operating sections of
this specification is not implied. Exposure to Absolute Maximum Rating conditions for
extended periods may affect device reliability. Refer also to the STMicroelectronics SURE
Program and other relevant quality documents.
3.2 Recommended operating conditions
Table 3. Absolute maximum ratings
Symbol Parameter Value Unit
V
I
Input voltage range
(1)
1. All voltage are referred to GND
-0.3 to 6 V
V
O
Output voltage range
(1)
-0.3 - (V
I
+ 0.3) V
V
IENX
EN Input voltage range -0.3 to 6 V
I
O
Continuous output current Internally Limited
ESD Electrostatic discharge 2 kV
T
J
Junction Operating Temperature -40 to 125 C
Table 4. Recommended operating conditions
Symbol Parameter Min Typ Max Unit
V
I
Input voltage range
(1)
1. All voltage are referred to GND
2.7 5.5 V
V
O
Output voltage range
(1)
05.5V
I
O
Continuous output current (Per switch) 0 500 mA