AFL Sensors
- 4 -
www.nve.com phone: 952-829-9217 fax: 952-829-9189
Electrical and Magnetic Specifications
Paramete
Min. Typ. Max. Units
Magnetic Operate Point (AFLxx0-xx) 7 10 13 |Oersteds|
Operate/Release Differential (AFLxx0-xx) 1 6 |Oersteds|
Magnetic Operate Point (AFLxx1-xx) 15 20 25 |Oersteds|
Operate/Release Differential (AFLxx1-xx) 3 10 |Oersteds|
Magnetic Operate Point (AFLxx2-xx) 21 28 34 |Oersteds|
Operate/Release Differential (AFLxx2-xx) 3 10 |Oersteds|
Magnetic Operate Point (AFLxx5-xx) 4 7 10 |Oersteds|
Operate/Release Differential (AFLxx5-xx) 1 6 |Oersteds|
Operating Voltage (AFL0xx-xx) 0.9 1.1 1.3 Volts
Operating Voltage (AFL1xx-xx) 1.8 2.2 2.5 Volts
Operating Voltage (AFL2xx-xx) 2.7 3.2 3.6 Volts
Operating Voltage (AFL3xx-xx) 4.5 5.0 5.5 Volts
Quiescent Current (AFL000-xx) 20 35 55
μA
Quiescent Current (AFL020-xx) 30 50 75
μA
Quiescent Current (AFL030-xx) 15 35 55
μA
Quiescent Current (AFL100-xx) 25 35 45
μA
Quiescent Current (AFL200-xx) 30 35 45
μA
Quiescent Current (AFL300-xx) 30 40 50
μA
Maximum Output Drive Current (Sink or Source) 100
μA
V
OL
at 100 μA Output Drive Current
0.200 Volts
V
OH
at 100 μA Output Drive Current
V
CC
−
0.150
Volts
Frequency Response 100 KHz
Temperature Range of Operation −20 85
°C
Notes:
1. Large magnetic fields WILL NOT damage NVE GMR Sensors
2. One Oersted (Oe) = 1 Gauss in air = 0.1 mT