FEB 14, 2006 revised to MAY 17, 2006 Page 1 of 14 www.power-one.com
HKS48T30120 DC-DC Series Data Sheet
Half-Brick with 48VDC Input; 12VDC @ 32A Output
Applications
Power systems utilizing IBA
(Intermediate Bus Architecture)
Networking equipment
Data/voice processing
Wireless communications
Computing
Benefits
Simplifies power system design; reduces design
time and technical risk
Compatible with all (12 Vin nom) POLs available in
the market
Features
RoHS lead free solder and lead solder exempted
products are available
Fully regulated output
High output power of 384 W
Flat efficiency curve to 94.5%
Wide-input voltage range from 35 to 75 VDC
100V/100ms input voltage surge withstand
Backdrive protection
Start-up into pre-biased load
Output overcurrent protection
Output overvoltage protection
Overtemperature protection
Remote on/off (primary referenced),
positive or negative logic option
Designed to comply with NEBS GR-1089 and GR-63
Basic insulation
Input-to-output isolation: 2121 VDC
Safety: UL60950-1, CSA C22.2 No. 60950-1-03,
TUV EN60950-1:2001, IEC60950-1:2001
Description
The HKS is a high density and highly efficient, isolated DC-DC converter that operates over an input voltage range
of 35 to 75 VDC. It provides a 12 VDC nominal, fully regulated output at up to 32 Amperes of direct current. The
converter is an ideal choice for building a complete power system utilizing the Intermediate Bus Architecture (IBA).
The thermally-optimized construction of the HKS allows the unit to provide high output current over a wide
operating temperature range while maintaining a safe guardband for electrical and thermal component ratings.
The HKS employs 100% surface-mount components for consistency and reliability in the production process.
Model Selection
Model
Input
Voltage
VDC
Input
Current,
Max ADC
1
Output
Voltage
VDC
Output Rated
Current I
rated
ADC
Output
Ripple/Noise,
mV
P-P
2
Typical
Eff.@ I
rated
%
HKS48T30120
35-75 12 12
(NOM.)
32 120
(NOM.)
94.5
1
@ V
IN
min.
2
(DC to 500 kHz)
FEB 14, 2006 revised to MAY 17, 2006 Page 2 of 14 www.power-one.com
HKS48T30120 DC-DC Series Data Sheet
Half-Brick with 48VDC Input; 12VDC @ 32A Output
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely effect long-
term reliability, and cause permanent damage to the converter.
Parameter Conditions/Description Min Max Units
Continuous 75 VDC Input voltage
Transient withstand 100 VDC
Hot Spot Monitor Location
2
-40 124
°C
Operating Temperature
Ambient -40 85
°C
Storage Temperature -55 125
°C
ON/OFF Control Voltage Referenced to -Vin -1 18 VDC
Output Power
1
384 W
1
with appropriate power derating, see figure 17.
2
See temperature probe locations Figure 18, 19.
Environmental and Mechanical Specifications
Parameter Conditions/Description Min Nom Max Units
Operating Humidity Relative Humidity, Non-cond. 95 %
Storage Humidity Relative Humidity, Non-cond. 95 %
Water Washing Standard process Yes
Shock Halfsine wave, 3 axes 50 G
Sinusoidal Vibration GR-63-CORE, Section 5.4.2 1 G
Weight 2.9 (82) Oz(g)
Dimensions (Overall) 2.28 (57.9) x 2.4 (61.0)
x 0.5 (12.7)
In.
(mm)
MTBF (Calculated) Per Telcordia SR-332 Issue 1,
(method 1, case 2, GB, 40
O
C)
1.2 MHrs
Isolation Specifications
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.
Parameter Conditions/Description Min Nom Max Units
Insulation Safety Rating Basic
Input to Output 2121 VDC
Input to Baseplate N/A
Isolation Voltage
Output to Baseplate N/A
Isolation Resistance Input to Output 10 M
Capacitance Input to Output 1,000 pF
FEB 14, 2006 revised to MAY 17, 2006 Page 3 of 14 www.power-one.com
HKS48T30120 DC-DC Series Data Sheet
Half-Brick with 48VDC Input; 12VDC @ 32A Output
EMI & Safety Regulatory Compliance
Safety Agency Standard Approved To: Marking
UL UL60950-1 / CSA C22.2 No. 60950-1-03 cURus
TUV product service TUV EN60950-1:2001 TUV PS Baurt mark
CB report IEC60950-1:2001 N/A
Declaration of Conformity DIR 73/23/EEC Low Voltage Directive
CE
Conducted Emissions
1
(with external EMI filter)
CISPR 22 class A
1
See figures 20 & 21.
Input Specifications
All specifications apply over the specified input voltage and output load at @ 40
º
C ambient temperature, unless
otherwise noted.
Parameter Conditions/Description Min Nom Max Units
Input Voltage Continuous 35 48 75 VDC
Maximum Input Current Vin =35V, Iout=I
RATED
12 ADC
Turn-On Input Voltage (UVLO)
1
Ramping Up 32.5 33.5 34.6 VDC
Turn-Off Input Voltage
1
Ramping Down 30.1 31.5 32.8 VDC
Turn-Off Hysteresis 1.5 VDC
Input Reflected Ripple Current I
RATED
, 12µH source inductance
BW=20MHz
2
15 50 mA
P-P
No-load Input Current 35VDC < Vin < 75VDCc 170 250 mA
No-load Power Dissipation Vin = 48VDC 8 W
Disabled Input Current 35VDC < Vin < 75VDC 21 24 mA
Inrush Transient Vin=Vin.max 2 A
2
s
1
See figure 2
2
Vin = 48 V, see Figures 1 & 10.
Output Specifications
All specifications apply over specified input voltage, output load, and @ 40
°
C ambient temperature, unless
otherwise noted.
Parameter Conditions/Description Min Nom Max Units
Output Voltage Set-point (Vin = 48 V, Io = 30 A) 11.7 12 12.3 VDC
< 0.03 0.06 VDC Line Regulation: (Vi = 35 V to 75 V, Io
RATED
)
< 0.25 0.5 % Vo
< 0.06 0.12 VDC Load Regulation: (Vin = 48 V, Io = 0 to 30 A)
< 0.5 1.0
% Vo
Temperature Regulation (T
AMBIENT
) = -40
O
C to +85
O
C) 0.005 0.03 %/
O
C
Total Error Band (Line, Load, Temperature,
Ripple, Life)
11.5 12 12.5 VDC
Dynamic Regulation
1
Peak Deviation
Settling Time
Peak Deviation
Settling Time
75-100-75% load step change,
to 1% error band, Co=220µF
di/dt = 1.0A/μs >>>
di/dt = 0.1A/μs >>>
+/-525
100
+/-400
100
+/-725
175
+/-550
175
mV
μs
mV
μs
1
See Figure 7.

HKS48T30120-NCA0

Mfr. #:
Manufacturer:
Bel Power Solutions
Description:
Isolated DC/DC Converters
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet