Refer to Application Notes
ECONOLINE
DC/DC-Converter
with 3 year Warranty
RxxP2xx/R
Selection Guide
Part Reinforced Input Output Output Efficiency Max
Number Isolation Voltage Voltage Current Std Capacitive
SIP 7 (kVDC) (VDC) (VDC) (mA) (%) Load
(1)
RxxP23.3S /R6.4 & /R8 5, 12, 15, 24 3.3 600 72-78 3300µF
RxxP205S /R6.4 & /R8 5, 12, 15, 24 5 400 79-84 1200µF
RxxP209S /R6.4 & /R8 5, 12, 15, 24 9 222 80-87 1200µF
RxxP212S /R6.4 & /R8 5, 12, 15, 24 12 167 80-87 680µF
RxxP215S /R6.4 & /R8 5, 12, 15, 24 15 132 80-88 680µF
RxxP23.3D /R6.4 & /R8 5, 12, 15, 24 ±3.3 ±300 73-80 ±1500µF
RxxP205D /R6.4 & /R8 5, 12, 15, 24 ±5 ±200 79-85 ±470µF
RxxP209D /R6.4 & /R8 5, 12, 15, 24 ±9 ±111 80-87 ±470µF
RxxP212D /R6.4 & /R8 5, 12, 15, 24 ±12 ±85 80-87 ±330µF
RxxP215D /R6.4 & /R8 5, 12, 15, 24 ±15 ±66 80-88 ±330µF
xx = Input Voltage. Other input and output voltage combinations available on request.
* add Suffix “P” for Continuous Short Circuit Protection, e.g.
R05P205S/P, R05P205D/P
* add Suffix “/X2” for single output with alternative pinout, e.g. R05P205S/X2, R05P205S/P/X2
* add Suffix “/R6.4” or “/R8” for Reinforced Isolation, e.g. R05P205D/R6.4, R05P205S/P/X2/R8
Input Voltage Range ±10%
Output Voltage Accuracy ±5%
Line Voltage Regulation 1.2%/1% of Vin typ.
Load Voltage Regulation 3.3, 5V output types 15% max.
(10% to 100% full load) other output types 10% max.
Output Ripple and Noise (20MHz BW) 200mVp-p max.
Operating Frequency 20kHz min. / 50kHz typ. / 85kHz max.
Efficiency at Full Load 65% min. / 80% max.
Minimum Load = 0% Specifications valid for 10% minimum load only.
Isolation Voltage /R6.4 (tested for 1 second) 6400VDC
(rated for 1 minute**) 3200VAC / 60Hz
/R8 (tested for 1 second) 8000VDC
(rated for 1 minute**) 4000VAC / 60Hz
Isolation Capacitance 1.5pF min. / 10pF max.
Isolation Resistance 15 GΩ min.
Short Circuit Protection 1 Second
P-Suffix Continuous
continued on next page
2 Watt
SIP 7 Single &
Dual Output
Derating-Graph
(Ambient Temperature)
●
UL/CSA and EN Safety certified
●
EN-61010 for Test, Measurement and Lab Use
●
EN-60601 for Medical Applications
●
Reinforced Isolation 6.4kVDC or 8kVDC
●
Optional Continuous Short Circuit Protected
●
Compact SIP7 Package
●
Efficiency to 88%
●
Very Low Isolation Capacitance
●
/X2 Version with >9mm Input/Output Clearance
Features
Unregulated
Converters
Description
Specifications (measured at T
A
= 25°C, nominal input voltage, full load and after warm-up)
The RxxP2xxS_D Series of DC/DC Converters are certified to UL/CSA-60950 and UL/CSA
60601. This makes them ideal for medical and safety applications where approved or reinforced
isolation is required. The reinforced versions are also EN61010-1 certified for Lab Equipment.
The /X2 version has an input/output clearance of more than 9mm.
E-314885
EN-60950-1 Certified
EN-60601-1 Certified
UL/CSA 60950-1 Certified
UL-60601 Certified
EN-61010-1 Certified
IEC-60601-1 CB Report
RoHS
2011/65/EU
6/6
**Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer
to our Application Notes.
REV: 3/2016 www.recom-power.comE-100