LFP240F-24

LFP-8
LFP300F
AC-DC Power Supplies Open Frame/ Enclosed Type
LF P 300 F -O -O
Ordering information
R
1 2 3 4 5 6
1 Series name
2 Single output
3 Output wattage
4 Universal input
5 Output voltage
6 Optional
*1
C
: with Coating
G
: Low leakage current
J :
EP (Tyco Electronics) connector type
J1
:
VH (J.S.T.) connector type
R
: with Remote ON/OFF
R2
:
with Remote ON/OFF
S
: with Chassis
SN
: with Chassis & cover
SNF
:
with Chassis & cover & fan (Only 24V)
T1
:
Holizontal terminal block
U1
:
Can be attached the external
capacitor unit
Recommended EMI/EMC Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit,
so handle the unit with care.
MODEL LFP300F-24-TY LFP300F-30-TY LFP300F-36-TY LFP300F-48-TY
MAX OUTPUT WATTAGE[W]
*2
360 (600) 360 (600) 360 (604.8) 360 (604.8)
DC OUTPUT
*2
Convection
24V 12.5A (25A) 30V 10A (20A) 36V 8.4A (16.8A) 48V 6.3A (12.6A)
Forced air
24V 15A (25A) 30V 12A (20A) 36V 10A (16.8A) 48V 7.5A (12.6A)
SPECIFICATIONS
MODEL LFP300F-24-TY LFP300F-30-TY LFP300F-36-TY LFP300F-48-TY
INPUT
VOLTAGE[V]
AC85 - 264 1f
(Refer to Instruction Manual 1.1 and 3.2)
*5
CURRENT[A]
ACIN 100V
4.3typ (Io=100%)
ACIN 200V
2.2typ (Io=100%)
FREQUENCY[Hz] 50 / 60 (47 - 63)
EFFICIENCY[%]
ACIN 100V
85.0typ (Io=100%) 85.5typ (Io=100%) 85.5typ (Io=100%) 85.5typ (Io=100%)
ACIN 200V
88.0typ (Io=100%) 88.0typ (Io=100%) 88.0typ (Io=100%) 88.0typ (Io=100%)
POWER FACTOR
ACIN 100V
0.99typ (Io=100%)
ACIN 200V
0.95typ (Io=100%)
INRUSH CURRENT[A]
ACIN 100V
15 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3 sec. to re-start)
ACIN 200V
30 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3 sec. to re-start)
LEAKAGE CURRENT[mA] 0.45 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
OUTPUT
VOLTAGE[V] 24 30 36 48
CURRENT[A]
ACIN 100V
*2
12.5 (Peak 22)
Convection
10 (Peak 18)
Convection
8.4 (Peak 14.6)
Convection
6.3 (Peak 11)
Convection
15 (Peak 22) Forced air 12 (Peak 18) Forced air 10 (Peak 14.6) Forced air 7.5 (Peak 11) Forced air
ACIN 200V
*2
12.5 (Peak 25)
Convection
10 (Peak 20)
Convection
8.4 (Peak 16.8)
Convection
6.3 (Peak 12.6)
Convection
15 (Peak 25) Forced air 12 (Peak 20) Forced air 10 (Peak 16.8) Forced air 7.5 (Peak 12.6) Forced air
LINE REGULATION[mV]
*7
96max 144max 144max 192max
LOAD REGULATION[mV]
*7
150max 240max 240max 240max
RIPPLE[mVp-p]
*3
0 to +40C
120max 150max 150max 150max
-10 - 0C
160max 200max 200max 200max
RIPPLE NOISE[mVp-p]
*3
0 to +40C
150max 250max 250max 250max
-10 - 0C
180max 300max 300max 300max
TEMPERATURE REGULATION[mV]
0 to +40C
240max 360max 360max 480max
-10 to +40
C
290max 450max 450max 600max
DRIFT[mV]
*
4
96max 144max 144max 192max
START-UP TIME[ms] 350typ (ACIN 100V, Io=100%)
HOLD-UP TIME[ms]
*
9
20typ (ACIN 100V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
21.60 to 27.50 27.00 to 33.00 32.40 to 39.60 39.60 to 52.80
OUTPUT VOLTAGE SETTING[V]
24.00 to 24.96 30.00 to 31.20 36.00 to 37.44 48.00 to 49.92
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 101% of rating and recovers automatically
OVERVOLTAGE PROTECTION[V]
27.60 to 33.60 34.50 to 42.00 41.40 to 50.40 55.20 to 67.20
OPERATING INDICATION Not provided
REMOTE SENSING Not provided
REMOTE ON/OFF Option (Refer to Instruction Manual 6)
ISOLATION
INPUT-OUTPUT
.
RC
*6
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
INPUT-FG
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
OUTPUT
.
RC-FG
*6
AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)
OUTPUT-RC
*6
AC100V 1minute, Cutoff current = 25mA, DC100V 10MW min (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
*5
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
VIBRATION
10 - 55Hz, 19.6m/
s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT 196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AG
ENCY APPROVALS (AT ONIY AC input)
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
HARMONIC ATTENUATOR
Complies with IEC61000-3-2 (Class A)
*8
OTHERS
CASE SIZE/WEIGHT
95X52.5X222mm
[3.74X2.07X8.74 inches]
(WXHXD) (without terminal block) / 810g max (with chassis & cover : 1,270g max)
COOLING METHOD
Convection / Forced air
(Refer to Instruction Manual 3.1 and 3.2)
*5
*1 Specifi cation is changed at option, refer to Instruction Manual.
*2 Peak loading for 10sec. And Duty 40% max, refer to Instruction
Manual 5. In detail.
( ) means peak current. There is a possibility that an internal
device is damaged when the specification is exceeded.
*3 This is the value that measured on measuring board with
capacitor of 22mF at 150mm from output terminal.
Measured by 20MHz oscilloscope or Ripple-Noise meter
(Equivalent to KEISOKU-GIKEN: RM103).
*4 Drift is the change in DC output for an eight hour period
after a half-hour warm-up at 25C, with the input voltage
held constant at the rated input/output.
*5 Derating is required.
*6 Applicable when remote control (optional) is added.
*7 Please contact us about dynamic load and input response.
*8 Please contact us about another class.
*9
By attaching an external capacitor unit, it is possible to extend the hold-up time.
* To meet the specifi cations. Do not operate over-loaded condition.
* Parallel operation is not possible.
* Derating is required when operated with chassis and cover.
* Sound noise may be generated by power supply in case of pulse load.
Please refer to Instruction manual 6.
LFP
me_lfp.indd LFP-8me lfp indd LFP-8 2015/06/15 15:25:362015/06/15 15:25:36
LFP-9
External view
Block diagram
LFP300F
External size of option is different from standard model.
Standard type
5 Mounting holes are existing.
The back side of P.C.B. of the power supply is assembled some
SMDs.
Be attention not to bump against the attached area by vibration.
Use the spacer of 8mm length or more regarding insulation.
And do not use press-fitting bush.
Point A, Point B, Point C, Point D are thermometry points.
Please refer to Instruction Manual 3.
Keep drawing current per pin below 20A for TB2.
Barrier strip type
Model B2B-XH-A
Mating Connector (Terminal)
RC(-)
RC(+)
2
1
ContentsPIN No.
or SXH-001T-P0.6
BXH-001T-P0.6
XHP-2
CN4 Option (Mfr:J.S.T)
Connector type
Output(+)
Output(-)
TB2
M4
M4
Input(N)
FG
Input(L)
TB1
Point D
Point C
Connector for
Remote ON/OFF
(Optional)
CN4
Point B
Point A
PCB t=1.6
Voltage adjust
Mounting Hole
4-f3.5
Mounting Hole
Name plate
2
1
18.5
10
8.6
222
52.5
8.6
10
5
109
±
0.5
212
±
0.5
5.5
46.5
85
±
0.5
5
95
49
4
3.5max
3.5
Tolerance : ±1 [±0.04]
Dimensions in mm, [ ]=inches
Screw tightening torque : M4 1.6N-m (16.9kgf-cm) max
Weight : 810g max (with chassis & cover : 1,270g max)
PCB material : CEM3
FG
1
Surface mount device
1
[0.2]
[1.83]
[0.16]
[0.2]
[2.07]
[0.39]
[0.34]
[3.74]
[1.93]
[0.14]
[0.14]
[0.22]
[0.73]
[0.39]
[0.34]
[8.74]
[4.29]
[8.35]
[3.35]
FG
DC OUT
AC IN 85
- 264V
RC
E
INRUSH
CURRENT
LIMIT
RECTIFIER
AND
FILTER
CONTROL
TRANSFORMER
CONTROL
OVER VOLTAGE
PROTECTION
NOISE
FILTER
RECTIFIER
AND
FILTER
INVERTER
RECTIFIER
CURRENT
SENSING
BOOSTER
INDUCTOR
INVERTER
CONTROL
CURRENT
SENSING
EXTERNAL
SOURCE
OPTION
250V10A
FUSE
Photocoupler
Photocoupler
Photocoupler
VC
OPTION
(Sell separately)
EXTERNAL
CAPACITOR
UNIT
LFP
me_lfp.indd LFP-9me lfp indd LFP-9 2015/06/15 15:25:392015/06/15 15:25:39

LFP240F-24

Mfr. #:
Manufacturer:
Cosel
Description:
Switching Power Supplies 240W 24V 10-12.5A AC-DC Power Supply
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union