55/0312-24-0CS2723

Date Revision
This specification sheet forms a part of the latest issue of Raychem Specification 55/.
55/0312
SPECIFICATION CONTROL DRAWING
TITLE
WIRE, RADIATION-CROSSLINKED MODIFIED ETFE INSULATED,
ULTRA LIGHTWEIGHT, OUTER SPACE, 600 VOLT
CONDUCTOR - SILVER-COATED COPPER
INSULATION - LOW OUTGASSING
RADIATION-CROSSLINKED,
MODIFIED ETFE
BEND TESTING
DIAMETER OF
STRANDED
CONDUCTOR
(in.)
WIRE
SIZE
(AWG)
CONDUCTOR
STRANDING
(number x AWG)
DIAMETER
(in.)
MAXIMUM
RESISTANCE
AT 20°C
(ohms/1000 ft.)
55/0312-28-*
55/0312-26-*
55/0312-24-*
55/0312-22-*
55/0312-20-*
55/0312-18-*
55/0312-16-*
55/0312-14-*
55/0312-12-*
55/0312-10-*
28
26
24
22
20
18
16
14
12
10
7 x 36
19 x 38
19 x 36
19 x 34
19 x 32
19 x 30
19 x 29
19 x 27
37 x 28
37 x 26
.0140
.0175
.0225
.0285
.0365
.0452
.0514
.0644
.0825
.1050
.0150
.0191
.0241
.0301
.0385
.0476
.0538
.0674
.0865
.1090
MAXIMUM
WEIGHT
(lbs/1000 ft.)
WEIGHT
(lb) (± 3%)
.0225 ± .0015
.0274 ± .0017
.0322 ± .0017
.0390 ± .0017
.0495 ± .0017
.0590 ± .0017
.0665 ± .0019
.0810 ± .0021
.1000 ± .0026
.1260 ± .0040
TABLE II. PERFORMANCE DETAILS
63.8
38.4
24.3
15.1
9.19
5.79
4.52
2.88
1.90
1.19
.81
1.22
1.80
2.70
4.27
6.56
8.33
12.81
19.71
31.70
FINISHED WIRE
MINIMUM MAXIMUM
PART NUMBER
1/
TABLE I. CONSTRUCTION DETAILS
TEMPERATURE RATING: 200°C
Maximum continuous conductor temperature
VOLTAGE RATING: 600 volts (rms) at sea level
CROSSLINK VERIFICATION: 300 ± 3°C for 1 hour
COLOR: White preferred
CONCENTRICITY: 80% (minimum)
IDENTIFICATION AND COLOR STRIPING DURABILITY:
125 cycles (250 strokes) (minimum), 500 g weight
INSULATION ELONGATION: 50% (minimum)
INSULATION FLAWS:
Spark Test, 1.5 kV (rms), (28 - 24 AWG)
3.0 kV (rms), (22 AWG & larger)
Impulse Dielectric Test, 6.0 kV (peak)
INSULATION THICKNESS: .004 in. (nominal)
RADIATION RESISTANCE: 500 megarads
SHRINKAGE: 230 ± 3°C for 1 hour, 0.125 in. (maximum) in 12 in.
VACUUM STABILITY:
Total Mass Loss (TML), 1.0% (maximum)
Volitale Condensable Material (VCM), 0.1% (maximum)
VOLTAGE WITHSTAND TEST (Post Environmental):
1500 volts (rms), 60 Hz, 5 minutes
PART NUMBER:
The "*" in the part numbers above shall be replaced
by color code designators.
1/ Example: AWG 20, white: 55/0312-20-9
WIRE RATINGS AND ADDITIONAL REQUIREMENTS
J1-30-06
CROSSLINK VERIFICATION
CROSSLINK VERIFICATION
MANDREL DIAMETER
(inch) (± 3%)
.250
.375
.375
.500
.500
.500
.750
1.00
1.50
2.00
.063
.063
.125
.188
.250
.250
.375
.500
.750
.750
55/0312-28-*
55/0312-26-*
55/0312-24-*
55/0312-22-*
55/0312-20-*
55/0312-18-*
55/0312-16-*
55/0312-14-*
55/0312-12-*
55/0312-10-*
PART NUMBER
1/
DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL.
Page 1 of 1
R Wire & Cable
501 Oakside Avenue
Redwood City, CA 94063-3800
Phone: 1-800-227-8816
Fax: 1-650-361-6297
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. OTHER CODES
AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL
REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
© 2006 Tyco Electronics Corporation. All rights reserved.

55/0312-24-0CS2723

Mfr. #:
Manufacturer:
Raychem / TE Connectivity
Description:
Hook-up Wire 55/0312-24-0CS2723 PRICE PER FOOT
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union