PS9308L, PS9308L2 Chapter Title
R08DS0048EJ0200 Rev.2.00 Page 7 of 20
Sep 27, 2013
SWITCHING CHARACTERISTICS (at RECOMMENDED OPERATING CONDITIONS,
V
EE
= GND, unless otherwise specified)
Parameter Symbol Conditions MIN. TYP.
*1
MAX. Unit
Propagation Delay Time (L → H) t
PLH
R
g
= 10 Ω, C
g
= 10 nF, 0.08 0.25
μ
s
Propagation Delay Time (H → L) t
PHL
f = 10 kHz, 0.10 0.25
μ
s
Pulse Width Distortion (PWD) |t
PHL
−t
PLH
| Duty Cycle = 50%, 0.02 0.1
μ
s
Propagation Delay Time
(Difference Between Any Two
Products)
t
PHL
−t
PLH
I
F
= 10 mA −0.1 0.1
μ
s
Rise Time t
r
50 ns
Fall Time t
f
50 ns
Common Mode Transient
Immunity at High Level Output
|CM
H
|
T
A
= 25°C, I
F
= 10 mA,
V
CC
= 30 V, V
CM
= 1.5 kV,
V
O (MIN.)
= 26 V
25 kV/
μ
s
Common Mode Transient
Immunity at Low Level Output
|CM
L
|
T
A
= 25°C, I
F
= 0 mA,
V
CC
= 30 V, V
CM
= 1.5 kV,
V
O (MAX.)
= 1 V
25 kV/
μ
s
Note: *1. Typical values at T
A
= 25°C.
<R>