ERZ-C20EK102Y

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
“ZNR” Transient/Surge Absorbers (Type E)
Current (A)
Voltage (V)
2000
1000
900
800
700
600
500
400
300
200
100
90
80
70
60
50
40
30
10
-
6
10
-
5
10
-
4
10
-
3
10
-
2
10
-
1
10
0
10
1
10
2
10
3
10
4
10
5
ERZC20EK511(Y)
ERZC20EK471(Y)
ERZC20EK431(Y)
ERZC20EK391(Y)
ERZC20EK361(Y)
ERZC20EK271(Y)
ERZC20EK241(Y)
ERZC20EK201(Y)
ERZC20EK201(Y)
ERZC20EK511(Y)
ERZC20EK471(Y)
ERZC20EK431(Y)
ERZC20EK391(Y)
ERZC20EK361(Y)
ERZC20EK271(Y)
ERZC20EK241(Y)
Test Current Waveform
10
-
6
to 10
-
3
A: Direct Current
10
-
1
to 10
4
A: 8/20 μs
Max. Clamping VoltageMax. Leakage Current
4000
3000
2000
1000
900
800
700
600
500
400
300
200
10
-
6
10
-
5
10
-
4
10
-
3
10
-
2
10
-
1
10
0
10
1
10
2
10
3
10
4
10
5
ERZC20EK112(Y)
ERZC20EK102(Y)
ERZC20EK911(Y)
ERZC20EK821(Y)
ERZC20EK781(Y)
ERZC20EK751(Y)
ERZC20EK621(Y)
ERZC20EK621(Y)
ERZC20EK681(Y)
ERZC20EK112(Y)
ERZC20EK102(Y)
ERZC20EK911(Y)
ERZC20EK821(Y)
ERZC20EK781(Y)
ERZC20EK751(Y)
ERZC20EK681(Y)
Current (A)
Voltage (V)
Test Current Waveform
10
-
6
to 10
-
3
A: Direct Current
10
-
1
to 10
4
A: 8/20 μs
Max. Clamping VoltageMax. Leakage Current
10000
8000
6000
4000
2000
1000
800
600
400
200
100
80
60
40
20
10
8
6
4
2
1
20 100 1000 10000
1 Time
2 Times
10 Times
10
2
Times
10
3
Times
10
4
Times
10
5
Times
10
6
Times
Impulse Width (μs)
Impulse Current (A)
5 minutes
2 minutes
10 seconds
2 times :
to 10 times :
to 10
6
times :
10000
8000
6000
4000
2000
1000
800
600
400
200
100
80
60
40
20
10
8
6
4
2
1
20 100 1000 10000
1 Time
10
2
Times
10
3
Times
10
4
Times
10
5
Times
10
6
Times
2 Times
10 Times
Impulse Width (μs)
Impulse Current (A)
5 minutes
2 minutes
10 seconds
2 times :
to 10 times :
to 10
6
times :
10000
8000
6000
4000
2000
1000
800
600
400
200
100
80
60
40
20
10
8
6
4
2
1
20 100 1000 10000
1
Time
10
2
Times
10
3
Times
10
4
Times
10
5
Times
10
6
Times
2
Times
10
Times
Impulse Width (μs)
Impulse Current (A)
5 minutes
2 minutes
10 seconds
2 times :
to 10 times :
to 10
6
times :
Voltage vs. Current
(ERZC20EK201(Y) to ERZC20EK511(Y))
(ERZC20EK621(Y) to ERZC20EK112(Y))
20 Series
(ERZC20EK751(Y) to ERZC20EK112(Y))
20 Series
(ERZC20EK361(Y) to ERZC20EK681(Y))
20 Series
(ERZC20EK201(Y) to ERZC20EK271(Y))
Typical Characteristics(Type E)
Impulse Derating Curve (Relation be tween impulse width and surge, repetitively)
Mar. 201703
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
“ZNR” Transient/Surge Absorbers (Type E)
2000
1000
900
800
700
600
500
400
300
200
100
90
80
70
60
50
40
30
10
-
6
10
-
5
10
-
4
10
-
3
10
-
2
10
-
1
10
0
10
1
10
2
10
3
10
4
10
5
ERZC32EK511(Y)
ERZC32EK471(Y)
ERZC32EK431(Y)
ERZC32EK391(Y)
ERZC32EK361(Y)
ERZC32EK271(Y)
ERZC32EK241(Y)
ERZC32EK201(Y)
ERZC32EK511(Y)
ERZC32EK471(Y)
ERZC32EK431(Y)
ERZC32EK391(Y)
ERZC32EK361(Y)
ERZC32EK271(Y)
ERZC32EK241(Y)
ERZC32EK201(Y)
Current (A)
Voltage (V)
Test Current Waveform
10
-
6
to 10
-
3
A: Direct Current
10
-
1
to 10
4
A: 8/20 μs
Max. Clamping VoltageMax. Leakage Current
4000
3000
2000
1000
900
800
700
600
500
400
300
200
10
-
6
10
-
5
10
-
4
10
-
3
10
-
2
10
-
1
10
0
10
1
10
2
10
3
10
4
10
5
ERZC32EK112(Y)
ERZC32EK102(Y)
ERZC32EK911(Y)
ERZC32EK821(Y)
ERZC32EK781(Y)
ERZC32EK751(Y)
ERZC32EK681(Y)
ERZC32EK621(Y)
ERZC32EK112(Y)
ERZC32EK102(Y)
ERZC32EK911(Y)
ERZC32EK821(Y)
ERZC32EK781(Y)
ERZC32EK751(Y)
ERZC32EK681(Y)
ERZC32EK621(Y)
Current (A)
Voltage (V)
Max. Clamping Voltage
Max. Leakage Current
Test Current Waveform
10
-
6
to 10
-
3
A: Direct Current
10
-
1
to 10
4
A: 8/20 μs
20 100 1000
1
Time
2
Times
10
Times
10
2
Times
10
3
Times
10
4
Times
10
5
Times
10
6
Times
10000
20000
10000
8000
6000
4000
2000
1000
800
600
400
200
100
80
60
40
20
10
8
6
4
2
Impulse Width (μs)
Impulse Current (A)
5 minutes
2 minutes
10 seconds
2 times :
to 10 times :
to 10
6
times :
Impulse Width (μs)
Impulse Current (A)
20 100 1000
1
Time
2
Times
10
Times
10
2
Times
10
3
Times
10
4
Times
10
5
Times
10
6
Times
10000
20000
10000
8000
6000
4000
2000
1000
800
600
400
200
100
80
60
40
20
10
8
6
4
2
5 minutes
2 minutes
10 seconds
2 times :
to 10 times :
to 10
6
times :
20 100 1000
1
Time
2
Times
10
Times
10
2
Times
10
3
Times
10
4
Times
10
5
Times
10
6
Times
10000
20000
10000
8000
6000
4000
2000
1000
800
600
400
200
100
80
60
40
20
10
8
6
4
2
Impulse Width (μs)
Impulse Current (A)
5 minutes
2 minutes
10 seconds
2 times :
to 10 times :
to 10
6
times :
Voltage vs. Current
(ERZC32EK201(Y) to ERZC32EK511(Y))
(ERZC32EK621(Y) to ERZC32EK112(Y))
32 Series
(ERZC32EK751(Y) to ERZC32EK112(Y))
32 Series
(ERZC32EK361(Y) to ERZC32EK681(Y))
32 Series
(ERZC32EK201(Y) to ERZC32EK271(Y))
Typical Characteristics(Type E)
Impulse Derating Curve (Relation be tween impulse width and surge, repetitively)
Mar. 201703
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
“ZNR” Transient/Surge Absorbers (Type E)
Electrical
Characteristics Test Methods/Description Specifi cations
Standard Test
Condition
Electrical characteristics shall be measured at following conditions
(Temperature: 5 to 35 °C,Humidity: Max. 85 %)
———
Varistor Voltage
The voltage between two terminals with the specified measuring
current CmA DC applied is called Vc or V
CmA
. The measurement shall
be made as fast as possible to avoid heat affection.
To meet the
specifi ed value.
Maximum Allowable
Voltage
The maximum sinusoidal wave voltage (rms) or the maximum DC
voltage that can be applied continuously.
Clamping Voltage
The maximum voltage between two terminals with the specified
standard impulse current (8/20 μs).
Rated Power
The maximum power that can be applied within the specified
ambient temperature.
Energy
The maximum energy within the varistor voltage change of ±10 %
when one impulse of 2 ms is applied.
Maximum
Peak Current
2 times
The maximum current within the varistor voltage change of ±10 %
with the standard impulse cur rent (8/20 μs) applied two times with
an interval of 5 minutes.
1 time
The maximum current within the varistor voltage change of ±10 %
with the standard impulse cur rent (8/20
μs
) applied one time.
Temperature Coefficient
of Varistor Voltage
V
C
at 70 °C V
C
at 20 °C
×
1
× 100 (%/°C)
V
C
at 20 °C 50
0 to –0.05 %/°C max.
Impulse Life
The change of Vc shall be measured after the impulse listed
below is applied 10000 times continuously with the interval of ten
sec onds at room temperature.
20 Series 200 A (8/20 μs)
32 Series 300 A (8/20 μs)
ΔV
1 mA
/V
1 mA
<
±10 %
Withstanding Voltage
(Body Insulation)
The commercial frequency voltage of AC 2.5 kV shall be applied
between terminals and the bottom of the unit for one minute.
No remarkable
damage
Mechanical
Robustness of
Terminations
(Tensile)
After gradually applying the load of 49 N (5 kgf) and keeping the
unit fi xed for 10 seconds in an axial direction, the terminal shall
be visually examined for any damage.
No remarkable
damage
Vibration
After repeadly applying a single harmonic vibration (amplitude:
0.75 mm): double amplitude: 1.5 mm with 1 minute vibration
frequency cycles (10 Hz to 55 Hz to 10 Hz) to each of three
perpendicular directions for 2 hours. Thereafter, the damage of
the ter mi nals is visually examined.
Environmental
Dry Heat/ High
Temperature
Storage
The specimen shall be subjected to 110±3 °C for 500 hours
in a thermostatic bath without load and then stored at room
temperature and humidity for one to two hours. Thereafter, the
change of Vc shall be measured.
Step Temperature (°C) Period (minutes)
1–25
–3
30
+3
2 Room Temp. 3 max.
385
+3
30
+3
4 Room Temp. 3 max.
ΔV
1 mA
/V
1 mA
<
±5 %
Temperature Cycle
The temperature cycle shown below shall be repeated five
times and then stored at room temperature and humidity for
one to two hours. The change of Vc and mechanical damage
shall be examined.
No remarkable
damage
ΔV
1 mA
/V
1 mA
<
±5 %
Dry Heat Load/
High Temperature
Load
After being continuously applied the Maximum Allowable Voltage
at 85±5 °C for 500 hours, the specimen shall be stored at room
temperature and humidity for one to two hours. Thereafter, the
change of Vc shall be measured.
ΔV
1 mA
/V
1 mA
<
±10 %
Damp Heat/Humidity
(Steady State)
The specimen shall be subjected to 40±2 °C, 90 to 95 %RH for
1000 hours without load and then stored at room temperature
and hu mid i ty for one to two hours. Thereafter, the change of Vc
shall be measured.
ΔV
1 mA
/V
1 mA
<
±5 %
0
0
0
0
Performance Characteristicsv (Type E)
Mar. 201703

ERZ-C20EK102Y

Mfr. #:
Manufacturer:
Panasonic
Description:
Varistors 1000V 8KA 48x42x14mm
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union