ADM1031
http://onsemi.com
30
Table 28. REGISTER 0X25 REMOTE 1 TEMP T
MIN
/T
RANGE
POWER-ON DEFAULT = 61H
Bit Name R/W Description
<7:3> Remote 1 Temp T
MIN
R/W Contains the minimum temperature value for automatic fan speed control based on
local temperature readings. T
MIN
can be programmed to positive values only in 4C
increments. Default is 32C.
00000 = 0C
00001 = 4C
00010 = 8C
00011 = 12C
|
|
01100 = 48C
|
|
|
11110 = 120C
11111 = 124C
<2:0> Remote 1 Temp T
RANGE
R/W This nibble contains the temperature range value for automatic fan speed control
based on the Remote 1 Temp Readings.
000 = 5C
001 = 10C (Default)
010 = 20C
011 = 40C
100 = 80C
Table 29. REGISTER 0X26 REMOTE 2 TEMP T
MIN
/T
RANGE
POWER-ON DEFAULT = 61H
Bit Name R/W Description
<7:3> Remote 2 Temp T
MIN
R/W Contains the minimum temperature value for automatic fan speed control based on
Remote 2 Temperature Readings. T
MIN
can be programmed to positive values only
in 4C increments. Default is 32C.
00000 = 0C
00001 = 4C
00010 = 8C
00011 = 12C
|
|
01100 = 48C (Default)
|
|
11110 = 120C
11111 = 124C
<2:0> Remote 2 Temp T
RANGE
R/W This nibble contains the temperature range value for automatic fan speed control
based on the Remote 2 Temp Readings.
000 = 5C
001 = 10C (Default)
010 = 20C
011 = 40C
100 = 80C
Table 30. REGISTER 0X3F THERM BEHAVIOR/REVISION POWER-ON DEFAULT = 80H
Bit Name R/W Description
<7> THERM-to-Fan En R/W Setting this bit to 1, enables the fan to run full-speed when THERM is asserted low.
This allows the system to be run in performance mode. Clearing this bit to 0 disables
the fan from running full-speed whenever THERM
is asserted low. This allows the
system to run in silent mode. (Power-On Default = 1).
<3:0> Revision R This nibble contains the revision number for the ADM1031.