_______________General Description
The MAX366 and MAX367 are multiple, two-terminal circuit
protectors. Placed in series with signal lines, each two-ter-
minal device guards sensitive circuit components against
voltages near and beyond the normal supply voltages.
These devices are used at interfaces where sensitive cir-
cuits are connected to the external world and could
encounter damaging voltages (up to 35V beyond the sup-
ply rails) during power-up, power-down, or fault conditions.
The MAX366 contains three independent protectors and
the MAX367 contains eight. They can protect analog sig-
nals using either unipolar (4.5V to 36V) or bipolar (±2.25V
to ±18V) power supplies. Each protector is symmetrical.
Input and output terminals may be freely interchanged.
These devices are voltage-sensitive MOSFET transistor
arrays that are normally on when power is applied and
normally open circuit when power is off. With ±10V sup-
plies, on-resistance is 100max and leakage is less than
1nA at +25°C.
When signal voltages exceed or are within approximately
1.5V of either power-supply voltage (including when
power is off), the two-terminal resistance increases dra-
matically, limiting fault current as well as output voltage to
sensitive circuits. The protected side of the switch main-
tains the correct polarity and clamps approximately 1.5V
below the supply rail. There are no “glitches” or polarity
reversals going into or coming out of a fault condition.
________________________Applications
Process Control Systems Redundant/Backup Systems
Hot-Insertion Boards/Systems ATE Equipment
Data-Acquisition Systems Sensitive Instruments
____________________________Features
±40V Overvoltage Protection
Open Signal Paths with Power Off
100Signal Paths with Power On
1nA Max Path Leakage at +25°C
44V Maximum Supply Voltage Rating
Automatic Protection; No Programming or
Controls
______________Ordering Information
MAX366/MAX367
Signal-Line Circuit Protectors
________________________________________________________________
Maxim Integrated Products
1
MAX366
OUT1
SENSITIVE
AMPLIFIER
1
FAULT!
FAULT!
IN1
(SHORT)
(OPEN)
REMOTE SENSOR
ELECTRONICS
7
+28V
+12V
OUT22 IN2 6
OUT33 IN3 5
V+
4
V-
PROTECTOR
+10V REG.
8
___________________________________________________Typical Operating Circuit
Call toll free 1-800-998-8800 for free samples or literature.
19-0326; Rev 0; 12/94
PART
MAX366CPA
MAX366CSA
MAX366C/D 0°C to +70°C
0°C to +70°C
0°C to +70°C
TEMP. RANGE PIN-PACKAGE
8 Plastic DIP
8 SO
Dice*
MAX366EPA
MAX366ESA
MAX366MJA -55°C to +125°C
-40°C to +85°C
-40°C to +85°C 8 Plastic DIP
8 SO
8 CERDIP**
MAX367CPN
MAX367CWN
MAX367C/D 0°C to +70°C
0°C to +70°C
0°C to +70°C 18 Plastic DIP
18 Wide SO
Dice*
MAX367EPN
MAX367EWN
MAX367MJN -55°C to +125°C
-40°C to +85°C
-40°C to +85°C 18 Plastic DIP
18 Wide SO
18 CERDIP**
Pin Configurations appear at end of data sheet.
MAX367 available after January 1, 1995.
* Dice are tested at T
A
= +25°C only.
* Contact factory for availability.
MAX366/MAX367
Signal-Line Circuit Protectors
2 _______________________________________________________________________________________
ABSOLUTE MAXIMUM RATINGS
ELECTRICAL CHARACTERISTICS
(V+ = +15V, V- = -15V, T
A
= T
MIN
to T
MAX
, unless otherwise noted.)
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
Note 1: Guaranteed, but not tested.
Note 2: See
Typical Operating Characteristics
curves for fault-free analog signal range at various supply voltages.
V+ to V-......................................................................-0.3V, +44V
IN_, OUT_..................................................(V- + 44V), (V+ - 44V)
Continuous Current into Any Terminal..............................±30mA
Peak Current into Any Terminal
(pulsed at 1ms, 10% duty cycle)...................................±70mA
Continuous Power Dissipation (T
A
= +70°C)
8-Pin Plastic DIP (derate 9.09mW/°C above +70°C) ....727mW
8-Pin SO (derate 5.88mW/°C above +70°C).................471mW
8-Pin CERDIP (derate 8.00mW/°C above +70°C).........640mW
18-Pin Plastic DIP (derate 11.11mW/°C above +70°C) ...889mW
18-Pin Wide SO (derate 9.52mW/°C above +70°C) .....762mW
18-Pin CERDIP (derate 10.53mW/°C above +70°C).....842mW
Operating Temperature Ranges
MAX36_C_ _ ........................................................0°C to +70°C
MAX36_E_ _......................................................-40°C to +85°C
MAX36_M_ _...................................................-55°C to +125°C
Storage Temperature Range.............................-65°C to +150°C
Lead Temperature (soldering, 10sec).............................+300°C
V+ = V- = 0V, V
OUT
= 0V,
V
IN
= ±35V
V+ = 15V, V- = -15V (Note 2)
(Note 1)
V+ = 10V, V- = -10V, V
IN
= ±5V,
I
OUT
= 1mA
V
IN
= ±10V, I
OUT
= 1mA
V
IN
= V+ or V-,
100k< R
OUT
< 1000M(Note 1)
V+ = 15V, V- = -15V, V
IN
= ±10V,
I
OUT
= 1mA
V+ = 5V, V- = -5V, V
IN
= ±2V,
I
OUT
= 1mA
CONDITIONS
nA
-10 10
I
IN(OFF)
Signal-Path Leakage
(with Overvoltage)
10
R
(IN-OUT)
Signal-Path Resistance Match
7
400
R
(IN-OUT)
Analog-Signal-Path Resistance
V-11 11V
IN
, V
OUT
V(V+ - 40) (V- + 40)V
IN
, V
OUT
Analog Signal Range
Fault-Free Analog Signal Range
140 350
150
125
62 100
V(V- + 3) (V+ - 1.5)V
OUT
Analog-Signal Output
Range (Fault)
62 85
100
125
UNITSMIN TYP MAXSYMBOLPARAMETER
+25°C
All
All
+25°C
M
C, E, M
C, E
+25°C
All
+25°C
C, E
+25°C
M
C, E, M
TEMP.
RANGE
V+ = V- = 0V, V
IN
= ±35V,
V
OUT
= open circuit
nA
-1000 1000
I
IN(OFF)
Signal-Path Leakage
(Power Off)
-10 10
C, E, M
+25°C
V
IN
= ±25V, V
OUT
= open circuit nA
-1000 1000
I
IN(ON)
Signal-Path Leakage
(with Fault Condition)
-10 10
C, E, M
+25°C
V
IN
= V
OUT
= ±10V nA
-100 100
I
OUT(ON)
Signal-Path Leakage
(without Fault Condition)
-1 1
C, E, M
+25°C
-1 1+25°C
R
(IN-OUT)
< 1000(Note 2) V±2.25 ±18V+, V-
Power-Supply Range
(without Fault Condition)
+25°C,
C, E, M
µA
-10 10
I+, I-Power-Supply Current
C, E, M
V0 ±18V+, V-Power-Supply Range
+25°C,
C, E, M
C, E, M -1000 1000
POWER SUPPLY
MAX366/MAX367
Signal-Line Circuit Protectors
_______________________________________________________________________________________
3
-25-35 15 25 35
TRANSFER CHARACTERISTICS
(BIPOLAR SUPPLIES)
MAX366/7-02
INPUT VOLTAGE (V)
OUTPUT VOLTAGE (V),
INPUT & OUTPUT CURRENT (µA)
0-15 -5 5
-15
15
0
-10
-5
10
5
V+ = +3V,
V- = -3V
V+ = +5V,
V- = -5V
V+ = +15V, V- = -15V
V+ = +15V, V- = -15V
V+ = +10V, V- = -10V
V+ = +10V, V- = -10V
OUTPUT
LOAD = 1M
15 25 3520 30
TRANSFER CHARACTERISTICS
(SINGLE SUPPLY)
MAX366/7-03
INPUT VOLTAGE (V)
V
IN
> (V+ - 35V)
OUTPUT VOLTAGE (V),
INPUT & OUTPUT CURRENT (µA)
0 105
15
0
10
25
20
5
V+ = 25V
V+ = 15V
V+ = 10V
V+ = 5V
OUTPUT LOAD = 1M
V- = 0V
1E+01
1E+02
1E+03
1E+04
1E+05
1E+06
1E+07
1E+08
-15 15
PATH RESISTANCE vs. INPUT VOLTAGE
(BIPOLAR SUPPLIES)
MAX366/7-04
INPUT VOLTAGE (V)
PATH RESISTANCE ()
0-10 -5 105
V± = ±15V
Circuit of Fig. 6
V± = ±10V
V± = ±5V
V± = ±3V
500
0
-15 15
PATH RESISTANCE vs. INPUT VOLTAGE
(BIPOLAR SUPPLIES)
400
MAX366/7-05
INPUT VOLTAGE (V)
PATH RESISTANCE ()
0
200
100
-10 -5 10
300
50
450
250
150
350
5
V± = ±15V
V± = ±10V
V± = ±5V
V± = ±3V
Circuit of Fig. 6
__________________________________________Typical Operating Characteristics
(V+ = +15V, V- = -15V, T
A
= +25°C, unless otherwise noted.)

MAX366CSA+

Mfr. #:
Manufacturer:
Maxim Integrated
Description:
Hot Swap Voltage Controllers Signal Line Circuit Protector
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union