Electrical specifications VND810PEP-E
8/24 Doc ID 10858 Rev 6
Note: To ensure long term reliability under heavy overload or short circuit conditions, protection
and related diagnostic signals must be used together with a proper software strategy. If the
device is subjected to abnormal conditions, this software must limit the duration and number
of activation cycles.
Table 5. Power outputs
Symbol Parameter Test conditions Min Typ Max Unit
V
CC
Operating supply
voltage
5.5 13 36 V
V
USD
Undervoltage shutdown 3 4 5.5 V
V
OV
Overvoltage shutdown 36 V
R
ON
On-state resistance
I
OUT
= 1A; T
j
= 25°C
I
OUT
= 1A; V
CC
> 8V
160
320
mΩ
mΩ
I
S
Supply current
Off-state; V
CC
= 13V;
V
IN
= V
OUT
= 0V
Off-state; V
CC
= 13V;
V
IN
= V
OUT
= 0V;
T
j
= 25°C
On-state; V
CC
= 13V; V
IN
= 5V;
I
OUT
= 0A
12
12
5
40
25
7
µA
µA
mA
I
L(off1)
Off-state output current V
IN
= V
OUT
= 0V 0 50 µA
I
L(off2)
Off-state output current V
IN
= 0V; V
OUT
= 3.5V -75 0 µA
I
L(off3)
Off-state output current
V
IN
= V
OUT
= 0V; V
CC
= 13V;
T
j
= 125°C
5µA
I
L(off4)
Off-state output current
V
IN
= V
OUT
= 0V; V
CC
= 13V;
T
j
= 25°C
3µA
Table 6. Protections and diagnostics
Symbol Parameter Test conditions Min. Typ. Max. Unit
T
TSD
Shutdown temperature 150 175 200 °C
T
R
Reset temperature 135 °C
T
hyst
Thermal hysteresis 7 15 °C
t
SDL
Status delay in overload
conditions
T
j
> T
TSD
20 µs
I
lim
Current limitation
V
CC
= 13V
5.5V < V
CC
< 36V
3.557.5
7.5
A
A
V
demag
Turn-off output clamp
voltage
I
OUT
= 1A; L = 6mH
V
CC
-
41
V
CC
-
48
V
CC
-
55
V