LTC4261/LTC4261-2
5
42612fd
For more information www.linear.com/LTC4261
SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNITS
I
2
C Interface Timing (Note 5)
f
SCL(MAX)
Maximum SCL Clock Frequency 400 kHz
t
LOW
Minimum SCL Low Period 0.65 1.3 µs
t
HIGH
Minimum SCL High Period 50 600 ns
t
BUF(MIN)
Minimum Bus Free Time Between Stop/
Start Condition
0.12 1.3 µs
t
HD,STA(MIN)
Minimum Hold Time After (Repeated)
Start Condition
140 600 ns
t
SU,STA(MIN)
Minimum Repeated Start Condition
Set-Up Time
30 600 ns
t
SU,STO(MIN)
Minimum Stop Condition Set-Up Time 30 600 ns
t
HD,DATI(MIN)
Minimum Data Hold Time Input –100 0 ns
t
HD,DATO(MIN)
Minimum Data Hold Time Output 300 600 900 ns
t
SU,DAT(MIN)
Minimum Data Set-Up Time Input 30 100 ns
t
SP(MAX)
Maximum Suppressed Spike Pulse
Width
50 110 250 ns
t
RST
Stuck-Bus Reset Time SCL or SDAI Held Low 25 66 ms
C
X
SCL,SDA Input Capacitance SDAI Tied to SDAO 5 10 pF
The l denotes the specifications which apply over the full operating
temperature range, otherwise specifications are at I
IN
= 5mA, T
A
= 25°C. (Note 2)
Note 1: Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. Exposure to any Absolute
Maximum Rating condition for extended periods may affect device
reliability and lifetime.
Note 2: All currents into pins are positive, all voltages are referenced to
device GND (V
EE
) unless otherwise specified.
Note 3: An internal shunt regulator limits the V
IN
pin to a minimum of
10.65V. Driving this pin to voltages beyond 10.65V may damage the part.
The pin can be safely tied to higher voltages through a resistor that limits
the current below 50mA.
Note 4: An internal clamp limits the DRAIN pin to a minimum of 3.5V.
Driving this pin to voltages beyond the clamp may damage the part. The
pin can be safely tied to higher voltages through a resistor that limits the
current below 2mA.
Note 5: Guaranteed by design and not subject to test.
ELECTRICAL CHARACTERISTICS