HIH-4602-A/C Series
2 www.honeywell.com/sensing
TABLE 1. PERFORMANCE SPECIFICATIONS (At 5 Vdc supply and 25 ºC [77 ºF] unless otherwise noted.)
Parameter Minimum Typical Maximum Unit Specific
Note
Interchangeability (first order curve)
– – – – –
0% RH to 59% RH -5
–
5 % RH
–
60% RH to 100% RH -8
–
8 % RH
–
Accuracy (best fit straight line)
-3.5 – +3.5
% RH
1
Hysterisis
–
3
–
% RH
–
Repeatability
–
±0.5
–
% RH
–
Settling time
– –
70 ms
–
Response time (1/e in slow moving air)
–
50
–
s
–
Stability (at 50% RH in one year)
–
±1.2
–
% RH
–
Voltage supply 4
–
5.8 Vdc
–
Current supply
– 200
500 µA
–
Output voltage temp. coefficient at 50% RH, 5 V – -4 – mV/ºC
–
Voltage output (1st order curve fit) V
OUT
=(V
SUPPLY
)(0.0062(sensor RH) + 0.16), typical at 25 ºC
Temperature compensation True RH = (sensor RH)/(1.0546-0.00216T), T in ºC
Operating temperature -40[-40] See Figure 1. 85[185] ºC[ºF]
–
Operating humidity 0 See Figure 1. 100 % RH
2
Storage temperature -50[-58]
–
125[257] ºC[ºF]
–
Storage humidity See Figure 2. % RH
2
Specific Notes:
1. Device is calibrated at 5 Vdc and 25 ºC.
2. Non-condensing environment.
General Notes:
• Sensor is ratiometric to supply voltage.
• Extended exposure to >
90% RH causes a reversible shift of
3% RH.
• Sensor is light sensitive. For best performance, shield sensor
from bright light.
FACTORY CALIBRATION DATA
HIH-4602 Sensors are supplied with a calibration and data
printout. See Table 2.
TABLE 2. EXAMPLE DATA PRINTOUT
Model HIH-4602-C
Channel 92
Wafer 030996M
MRP 337313
Calculated values at 5 V
V
OUT
at 0% RH
V
OUT
at 75.3% RH
0.826 V
3.198 V
Linear output for 3.5% RH
accuracy at 25 °C
Zero offset
Slope
RH
0.826 V
31.483 mV/%RH
(V
OUT
- zero offset)/slope
(V
OUT
- 0.826)/0.0315
Ratiometric response for
0% RH to 100% RH
V
OUT
V
SUPPLY
(0.1652 to 0.7952)
TABLE 3. HIH-4602-A NTC THERMISTOR TEMPERATURE
SPECIFICTIONS
Rb = 100 kOhm ±5% at 25 ºC
Beta = 4250, 25 ºC to 85 ºC
1/T = a + b(Ln R) + c(Ln R) ^ 3, T in degrees K
Low
Mid
High
Temp. ºC
0
50
100
Resistance
351000
33590
5569
a = 0.000828083
b = 0.000208691
c = 8.0812E-08
TABLE 4. HIH-4602-C RTD TEMPERATURE SENSOR
SPECIFICATIONS
Thin film platinum RTD – Class 2B (Ro: ±0.25%)
DIN EN 60571 (PER IEC 751)
TCR = 3750 ppm/ºC
1000 Ohm at 0 ºC [32 ºF]