BH1414K
Multimedia ICs
(3) Explanation of the serial data
· It is the data which sets the program counter number of the dividing.
This data can set a transmission frequency.
· It is a binary value. It sets D
11
With MSB and it sets D
0
with LSB.
· It controls EVR. L-ch and R-ch are set at the same time.
Example
In case of 99.7MHz oscillation
99.7MHz÷100kHz(fref)=997→3E5(HEX)
(1)
(2)
(3)
(4)
PROGRAM COUNTER
D
0
~D
11
EVR
VR
0
~VR
3
MULTIPLEXER
PL
VCO
VCO
1
, VCO
2
No.
Control unit Contents
D
0
D
1
D
2
D
3
D
4
D
5
D
6
D
7
D
8
D
9
D
10
D
11
5
1 1 11111000 00
E3
LSB MSB
VR
0
VR
1
VR
2
VR
3
EVR GAIN
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
0
0
1
1
0
0
0
0
1
1
0
0
1
1
1
0
1
0
1
0
1
0
0
1
0
1
0
1
0
1
−6
−6
−5
−4
−3
−2
−1
0
0
+1
+2
+3
+4
+5
+6
+6
· It changes a stereo and monaural operation.
PL Condition of the composite signal
0
1
Stereo operation
Monaural operation
L+R+ (L−R) sin ω
s
t+P sin t
2
ω
s
L+R, Pilot OFF
· It controls the VCO operation.
VCO
1
VCO
2
VCO
0 0 or 1
0 or 1
1
Enable
Disable
· It controls open collector output.
· It controls change pump output by the phase comparator compulsorily.
(5)
(6)
· It is data for the LSI test.
· Always Input "00".
(7)
PHASE DETECTOR
PD
0
, PD
1
TEST MODE
T
0
, T
1
PORT(Pin29)
PO
PO Open collector output
0
1
High impedance
Low (ON)
PD
0
PD
1
Charge pump output
00
0
0
1
11
1
Usual operation
High impedance
Compulsion by Low