MPS-120-48

Specification
(Typ.)
(Typ.)
(Typ.)
ACINPUTVOLTAGE
ACINPUTCURRENT
INRUSHCURRENT
SETUP,RISETIME
HOLD-UP TIME
LEAKAGECURRENT
DCOUTPUT ADJ.RANGE
OVERLOADPROTECTION
OVERVOLTAGEPROTECTION
POWERGOOD/FAIL SIGNAL (OPTIONAL)
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
90~264VAC,47~440Hz/127~370VDC.
Maximuminputcurrent2.9A at115VAC,60Hzor
1.7A at230VAC,60Hzwith100%outputload.
Inrushcurrentislessthan22A at115VACorlessthan
45A at230VACundercoldstartconditions.Limiting
providedbyinternalthermistors.
MPS-120: 800ms,20ms/230VACatfullload
2000ms,50ms/115VACatfullload
MPD,T,Q-120:500ms,20ms/230VACatfullload
1200ms,50ms/115VACatfullload
80ms/230VACatfullload
14ms/115VACatfullload
Leakagecurrentislessthan180 A at264VAC
DCoutputvoltage(orCh1ofmultipleoutputmodels)
canbeadjustedbetween-5%~+10%ratedoutput
voltagebypotentialmeter.
Fullyprotectedagainstshortcircuitandoutputoverload.
Thehiccuptypeprotection willbeactivatedat110~150%
(ForMPD,T,Q-120),120~160%(ForMPS-120)ratedload
andrecoversautomaticallyafterfaultconditionis removed.
Providedonoutputchannel1onlyat115%~135%
ratedoutputvoltage.(120%~140%forMPS-120-15/24/48).
Outputwillbeshutdownwhenthisprotectionisactivated.
*MPS-120-3.3doesnothavethisoptionalfunction.
Wholeseriescanoperatefrom-20~70 .Pleaserefer
tothederatingcurves.
20~90%RHnon-condensing.
-40~+85 ,10~90%RH
TTL logichighforpowergoodand TTL lowfor
powerfail.Whentheoutputvoltagereaches90%of
ratedvalue,a+5V TTL signalwillbesentoutwitha
10~500msdelay; Atleast1msbeforetheoutput
voltagegoesbelow90%oftheratedvalue,the TTL
signalwillbeturnedoff.
ComplianceLevel
EN55011,ClassB
EN55022,ClassB
EN61000-3-2
EN61000-3-3
ComplianceLevel
EN61000-4-2,
EN61000-4-2,
EN61000-4-3,
EN61000-4-4,
EN61000-4-5,
EN61000-4-6,
EN61000-4-8,
EN61000-4-11,
ENV50204,
Level3,8KV
Level2,4KV
Level2,3V/m
Level3,10V/m
Level2,1KV/5KHz
Level3,2KV/5KHz
Level4,2KV/Line-Line
4KV/Line-Earth
Level2,3Vrms/m
Level3,10Vrms/m
Level2,3A/m
Level3,10A/m
Compliance
Level2,3V/m,900MHz
Level3,10A/m,900MHz
1~4OutputMedical Type
120WMedical ser i e s
Universal ACinput/Fullrange
Lowleakagecurrent<180 A
Protections:Shortcircuit/Overload/Overvoltage
UL60601-1medicalsafetyapproved
Withpowergoodandfailsignaloutput(Optional)
100%fullloadburn-intest
Fixedswitchingfrequencyat45KHz
3yearswarranty
Features
TEMP.COEFFICIENT
VIBRATION
SAFETY STANDARDS
:
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
EMICOMPLIANCE
EMSCOMPLIANCE
MTBF
DIMENSION(L*W*H)
PACKING
2Gofacceleration,vibratingfrequencyadjustfrom10Hz~500Hzwithina
10-minutecycle.6testingcycles(60minutes)eachalongX, Y,Zaxes.
Medical UL60601-1, TUVEN60601-1 approved
Commercial: AlsodesignrefertoUL60950-1, TUVEN60950-1
4000VACbetweeninputandoutput
1500VACbetweeninputandF.G.
500VACbetweenoutputandF.G.
EMISpecifications
EMSSpecification
ESDair
ESDcontact
RFfieldsusceptibility
EFT(ElectricalFast Transient)/Burst
Lightning/Surge
ConductedRFsusceptibility
Magneticfieldimmunity
Voltagedip,interruption
Digitalphonecarrierimmunity
262,100hoursmin.atfullloadand25 ofambienttemperature,
calculatedperMIL-HDBK-217F.
177.8x107.95x35.5mmor7"x4.25"x1.4"
0.55Kg;24pcs/14.5Kg/0.99CUFT
,
0.04%/ onalloutputsatfullloadbetween0~50 ofambienttemperature.
>100MOhmsforI/P-O/P,I/P-FG,O/P-FGbyusing500VDCtestvoltage.
Conducted&Radiation
Harmonicdistortion
Voltageflicker
IEC60601-1
FileName:120WMEDICAL-SPEC2011-03-31
EN60601-1
IEC60601-1
1~4OutputMedical Type
120WMedical ser i e s
Notes:
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 f & 47 f parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
6. Heat Sink HS1,HS2 can not be shorted.
For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
OutputChart
MODEL
OUTPUT RATED
OUTPUTCURRENT
PEAKLOAD
WITHFAN
CONVECTION
MINIMUM
RIPPLE&NOISE
VOLTAGE
LINE LOAD
EFFICIENCY
VOLTAGE CURRENT
( )Note4
(25CFM)
(max.)
LOAD
(Max.)
TOLERANCE
REGULATION
REGULATION
MPS-120-3.3
3.3V 0A24A 16A 24A 26A 80mVp-p 3.0% 1.0% 3.0% 68%
73%
77%
79%
81%
82%
75%
72%
73%
72%
71%
71%
74%
73%
74%
76%
1.0% 3.0%
1.0% 2.0%
2.0%
2.0%
2.0%
0.5%
1.0%
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
1.0%
3.5%
3.5%
3.5%
3.5%
3.5%
3.5%
3.0%
+4,-3%
1.0%
1.0%
1.0%
1.0%
1.0%
3.5%
3.0%
1.0%
1.0%
1.0%
1.0%
1.0%
0.5%
3.5%
4.0%
1.0%
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
1.5%
1.5%
2.0%
1.5%
2.0%
2.0%
2.0%
3.0%
0.5%
0.5%
0.5%
0.5%
0.5%
2.0%
2.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
2.0%
2.0%
3.0%
2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
2.0%
6.0%
2.0%
6.0%
+6,-7%
6.0%
+6,-7%
+8,-6%
+8,-6%
+8,-6%
5.0%
5.0%
5.0%
5.0%
5.0%
8.0%
8.0%
5.0%
5.0%
5.0%
5.0%
5.0%
2.0%
7.0%
8.0%
80mVp-p
100mVp-p
100mVp-p
120mVp-p
120mVp-p
80mVp-p
80mVp-p
80mVp-p
80mVp-p
80mVp-p
80mVp-p
80mVp-p
80mVp-p
80mVp-p
120mVp-p
120mVp-p
150mVp-p
120mVp-p
150mVp-p
150mVp-p
120mVp-p
300mVp-p
80mVp-p
80mVp-p
80mVp-p
80mVp-p
80mVp-p
300mVp-p
80mVp-p
80mVp-p
80mVp-p
80mVp-p
80mVp-p
120mVp-p
80mVp-p
120mVp-p
250mVp-p
5V 0A22A 14.7A 22A
26A
0A10A 6.7A 10A 11A
0A8A 5.3A 8A 8.8A
0A5A 3.3A 5A 5.5A
0A
2A
2A
2A
2A
2A
2A
2A
2A
2A
0.4A
0.4A
0.4A
0.5A
0.5A
0.2A
0.5A
0.4A
0A
0A
0A
0A
0A
0.3A
0A
0A
0A
0A
0A
0A
2A
0.5A
0.3A
2.5A
10A
10A
10A
10A
10A
10A
10A
10A
10A
4.8A
4.4A
4A
4.2A
3.2A
1A
3A
2.2A
0.6A
0.6A
0.6A
0.6A
0.6A
2.1A
0.6A
0.6A
0.6A
0.6A
0.6A
0.6A
10A
5A
2.9A
1.7A
7.3A
7.3A
7.3A
7A
7.3A
7.3A
7A
7.3A
7.3A
3.5A
3.2A
2.6A
3.1A
2.4A
0.7A
2.3A
1.6A
0.3A
0.4A
0.4A
0.4A
0.4A
1.4A
0.4A
0.4A
0.4A
0.3A
0.4A
0.4A
7A
3.6A
1.9A
2.5A
10A
10A
10A
10A
10A
10A
10A
10A
10A
4.8A
4.4A
4A
4.2A
3.2A
1A
3A
2.2A
0.6A
0.6A
0.6A
0.6A
0.6A
2.1A
0.6A
0.6A
0.6A
0.6A
0.6A
0.6A
10A
5A
2.9A
2.8A
12A
12A
12A
11A
11A
11A
11A
11A
12A
5.8A
5.3A
4.4A
5A
3.8A
1.1A
3.3A
2.64A
1A
1A
1A
1A
1A
2.3A
1A
1A
1A
1A
1A
1A
12A
6A
3.2A
12V
15V
24V
48V
5V
5V
5V
5V
5V
5V
5V
5V
5V
12V
12V
15V
12V
15V
12V
12V
24V
-5V
-12V
-15V
-5V
-5V
24V
15V
-12V
-15V
-12V
24V
12V
5V
12V
24V
MPS-120-5
MPS-120-12
MPS-120-15
MPS-120-24
MPS-120-48
MPD-120A
MPT-120A
MPT-120B
MPT-120C
MPQ-120B
MPQ-120C
MPQ-120D
MPQ-120E
MPT-120D
MPD-120B
WITH25CFMFAN
(Note3)
(Note2)
FileName:120WMEDICAL-SPEC2011-03-31
(HORIZONTAL)
HS1,HS2 can not be shorted
ACInputConnector(CN1):Molex5273-05orequivalent
DCOutputConnector(CN2):Molex5273-13orequivalent
PinNo.
PinNo.
3
3
1
1
5
4
5
6
7
8
9
10
11
12
13
2,4
2
MPS-120
MPS-120
MPD-120
MPD-120
MPT-120
MPT-120
MPQ-120
MPQ-120
MatingHousing
MatingHousing
Terminal
Terminal
AC/L
-V
-V
-V
-V
+V
+V
P.F.D.
NC
NoPin
NC
AC/L
COM
COM
COM
COM
V2
V2
P.F.D.
NC
NoPin
NC
AC/L
COM
COM
COM
COM
V2
V2
P.F.D.
V3
NoPin
NC
AC/L
COM
COM
COM
COM
V2
V2
P.F.D.
V3
NoPin
V4
NoPin
+V
+V
+V
NoPin
V1
V1
V1
NoPin
V1
V1
V1
NoPin
V1
V1
V1
AC/N AC/N AC/N AC/N
Molex5195
Molex5195
Molex5194
Molex5194
orequivalent
orequivalent
orequivalent
orequivalent
FG FG FG FG
Unit:mm
MechanicalSpecification
95.25[3.75"]
107.95[4.25"]
165.1[6.5"]
177.8[7"]
13
6
2
CN2
1
4
3
5
9
7
8
11
10
12
+V ADJ
HS2
HS1
CN1
2
3
1
4
5
4- 3.96[0.156"]
FAN
10cm
DeratingCurve
Pin Assignment
StaticCharacteristics
90 100 115 135 155 264230
100
90
80
70
60
50
40
INPUTVOLTAGE(V)60Hz
LOAD(%)
1~4OutputMedical Type
120WMedical ser i e s
FileName:120WMEDICAL-SPEC2011-03-31
LOAD(%)
10 20 30 40 50 55 60 70
20
40
60
80
100
-20 0
25CFMforcedaircooling
Convectioncooling
53WMPS-120-3.3only
73.7WMPS-120-5only
80Wothers
AMBIENTTEMPERATURE( )
MPS/D-120
MPT/Q-120
35.5[1.4"]
2 max.[0.078"]

MPS-120-48

Mfr. #:
Manufacturer:
Description:
AC to DC Power Supply Open Frame Single Output 48 Volt 1.7 A
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet