4
Solder Reow Thermal Prole
Recommended reow condition as per JEDEC Standard, J-STD-020 (latest revision). Non-Halide Flux should be used.
Regulatory Information
The HCPL-x710 have been approved by the following organizations:
UL Recognized under UL 1577, component recognition program, File E55361.
CSA Approved under CSA Component Acceptance Notice #5, File CA 88324.
IEC/EN/DIN EN 60747-5-5
Small Outline SO-8 Package
Test Rating Code, Z Optional Identication Code
L – Option x2x
V – Option x5x or x6x
A – Avago
– UL Logo
P – Special Program Code
7.49 (0.295)
1.9 (0.075)
0.64 (0.025)
LAND PATTERN RECOMMENDATION
8 7 6 5
4321
5.994 ± 0.203
(0.236 ± 0.008)
3.937 ± 0.127
(0.155 ± 0.005)
0.406 ± 0.076
(0.016 ± 0.003)
1.270
(0.050)
BSC
5.080 ± 0.127
(0.200 ± 0.005)
3.175 ± 0.127
(0.125 ± 0.005)
1.524
(0.060)
45° X
0.432
(0.017)
0.228 ± 0.025
(0.009 ± 0.001)
0.305
(0.012)
MIN.
TOTAL PACKAGE LENGTH (INCLUSIVE OF MOLD FLASH)
5.207 ± 0.254 (0.205 ± 0.010)
DIMENSIONS IN MILLIMETERS (INCHES).
LEAD COPLANARITY = 0.10 mm (0.004 INCHES) MAX.
OPTION NUMBER 500 NOT MARKED.
NOTE: FLOATING LEAD PROTRUSION IS 0.15 mm (6 mils) MAX.
0.203 ± 0.102
(0.008 ± 0.004)
0 ~ 7°
*
*
YYWW
NNNN Z
EEE
TEST RATING CODE
DEVICE PART
NUMBER
LEAD-FREE
LOT ID
DATE CODE
PIN 1
5
All Avago data sheets report the creepage and clearance inherent to the optocoupler component itself. These dimen-
sions are needed as a starting point for the equipment designer when determining the circuit insulation requirements.
However, once mounted on a printed circuit board, minimum creepage and clearance require ments must be met as
specied for individual equipment standards. For creepage, the shortest distance path along the surface of a printed
circuit board between the solder llets of the input and output leads must be considered. There are recommended
techniques such as grooves and ribs, which may be used on a printed circuit board to achieve desired creepage and
clearances. Creepage and clearance distances will also change depending on factors such as pollution degree and
insulation level.
Insulation and Safety Related Specications
Value
Parameter Symbol 7710 0710 Units Conditions
Minimum External Air L(I01) 7.1 4.9 mm Measured from input terminals to output
Gap (Clearance) terminals, shortest distance through air.
Minimum External L(I02) 7.4 4.8 mm Measured from input terminals to output
Tracking (Creepage) terminals, shortest distance path along body.
Minimum Internal Plastic 0.08 0.08 mm Insulation thickness between emitter and
Gap (Internal Clearance) detector; also known as distance through
insulation.
Tracking Resistance CTI ≥175 ≥175 V DIN IEC 112/VDE 0303 Part 1
(Comparative Tracking Index)
Isolation Group IIIa IIIa Material Group (DIN VDE 0110, 1/89, Table 1)
6
IEC/EN/DIN EN 60747-5-5 Insulation Related Characteristics* (Option 060)
Characteristic
Description Symbol HCPL-7710 HCPL-0710 Units
Installation classication per DIN VDE 0110, Table 1
for rated mains voltage ≤ 150 V
rms
I-IV I-IV
for rated mains voltage ≤ 300 V
rms
I-IV I-III
for rated mains voltage ≤ 600 V
rms
I-IV I-III
Climatic Classication 55/85/21 55/85/21
Pollution Degree (DIN VDE 0110/39) 2 2
Maximum Working Insulation Voltage V
IORM
630 567 V
peak
Input-to-Output Test Voltage, Method b* V
PR
1181 1063 V
peak
V
IORM
x 1.875 = V
PR
, 100% Production Test with
t
m
= 1 sec, Partial Discharge < 5 pC
Input-to-Output Test Voltage, Method a* V
PR
1008 907 V
peak
V
IORM
x 1.6 = V
PR
, Type and Sample Test,
t
m
= 10 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage V
IOTM
8000 6000 V
peak
(Transient Overvoltage, t
ini
= 60 sec)
Safety Limiting Values - maximum values allowed
in the event of a failure
Case Temperature T
S
175 150 °C
Input Current I
S,INPUT
230 150 mA
Output Power P
S,OUTPUT
600 600 mW
Insulation Resistance at T
S
, V
10
= 500 V R
IO
≥10
9
≥10
9
Ω
* Refer to the front of the optocoupler section of the Isolation and Control Component Designer’s Catalog, under Product Safety Regulations sec-
tion IEC/EN/DIN EN 60747-5-5, for a detailed description of Method a and Method b partial discharge test proles.
Note: These optocouplers are suitable for “safe electrical isolation only within the safety limit data. Maintenance of the safety data shall be
ensured by means of protective circuits.
Note: The surface mount classication is Class A in accordance with CECC 00802.
Absolute Maximum Ratings
Parameter Symbol Min. Max. Units
Storage Temperature T
S
–55 125 °C
Ambient Operating Temperature T
A
–40 +100 °C
Supply Voltages V
DD1
, V
DD2
0 6.0 Volts
Input Voltage V
I
–0.5 V
DD1
+0.5 Volts
Output Voltage V
O
–0.5 V
DD2
+0.5 Volts
Input Current I
I
–10 +10 mA
Average Output Current I
O
10 mA
Lead Solder Temperature 260°C for 10 sec., 1.6 mm below seating plane
Solder Reow Temperature Prole See Solder Reow Temperature Prole Section
Recommended Operating Conditions
Parameter Symbol Min. Max. Units
Ambient Operating Temperature T
A
–40 +100 °C
Supply Voltages V
DD1
, V
DD2
4.5 5.5 V
Logic High Input Voltage V
IH
2.0 V
DD1
V
Logic Low Input Voltage V
IL
0.0 0.8 V
Input Signal Rise and Fall Times t
r
, t
f
1.0 ms

HCPL-0710

Mfr. #:
Manufacturer:
Broadcom / Avago
Description:
High Speed Optocouplers 1Ch 150mA 600mW
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: