6
IEC/EN/DIN EN 60747-5-5 Insulation Related Characteristics* (Option 060)
Characteristic
Description Symbol HCPL-7710 HCPL-0710 Units
Installation classication per DIN VDE 0110, Table 1
for rated mains voltage ≤ 150 V
rms
I-IV I-IV
for rated mains voltage ≤ 300 V
rms
I-IV I-III
for rated mains voltage ≤ 600 V
rms
I-IV I-III
Climatic Classication 55/85/21 55/85/21
Pollution Degree (DIN VDE 0110/39) 2 2
Maximum Working Insulation Voltage V
IORM
630 567 V
peak
Input-to-Output Test Voltage, Method b* V
PR
1181 1063 V
peak
V
IORM
x 1.875 = V
PR
, 100% Production Test with
t
m
= 1 sec, Partial Discharge < 5 pC
Input-to-Output Test Voltage, Method a* V
PR
1008 907 V
peak
V
IORM
x 1.6 = V
PR
, Type and Sample Test,
t
m
= 10 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage V
IOTM
8000 6000 V
peak
(Transient Overvoltage, t
ini
= 60 sec)
Safety Limiting Values - maximum values allowed
in the event of a failure
Case Temperature T
S
175 150 °C
Input Current I
S,INPUT
230 150 mA
Output Power P
S,OUTPUT
600 600 mW
Insulation Resistance at T
S
, V
10
= 500 V R
IO
≥10
9
≥10
9
Ω
* Refer to the front of the optocoupler section of the Isolation and Control Component Designer’s Catalog, under Product Safety Regulations sec-
tion IEC/EN/DIN EN 60747-5-5, for a detailed description of Method a and Method b partial discharge test proles.
Note: These optocouplers are suitable for “safe electrical isolation” only within the safety limit data. Maintenance of the safety data shall be
ensured by means of protective circuits.
Note: The surface mount classication is Class A in accordance with CECC 00802.
Absolute Maximum Ratings
Parameter Symbol Min. Max. Units
Storage Temperature T
S
–55 125 °C
Ambient Operating Temperature T
A
–40 +100 °C
Supply Voltages V
DD1
, V
DD2
0 6.0 Volts
Input Voltage V
I
–0.5 V
DD1
+0.5 Volts
Output Voltage V
O
–0.5 V
DD2
+0.5 Volts
Input Current I
I
–10 +10 mA
Average Output Current I
O
10 mA
Lead Solder Temperature 260°C for 10 sec., 1.6 mm below seating plane
Solder Reow Temperature Prole See Solder Reow Temperature Prole Section
Recommended Operating Conditions
Parameter Symbol Min. Max. Units
Ambient Operating Temperature T
A
–40 +100 °C
Supply Voltages V
DD1
, V
DD2
4.5 5.5 V
Logic High Input Voltage V
IH
2.0 V
DD1
V
Logic Low Input Voltage V
IL
0.0 0.8 V
Input Signal Rise and Fall Times t
r
, t
f
1.0 ms