34222

© 2016 DESCO INDUSTRIES INC.
Employee Owned
3651 WALNUT AVE., CHINO, CA 91710
PHONE: (909) 627-2453
WEBSITE: MendaPump.com
DATE:
Jan.
2016
DRAWING NUMBER
34205
CONDUCTIVE C-TYPE CONNECTOR COVERS
Made in the
United States of America
Chemical Susceptibility* Reactions
Dilute Acids Slight Attack
Dilute Alkalines
Slight Attack
Concentrated Acids
Slight Attack
Concentrated Alkalines
Slight Attack
Methanol, Ethanol, Isopropanol
Resistant
Hydrocarbons
Slight Attack
Ketones
Slight Attack
Oil and Gasoline
Slight Attack
Item No. Size “A” “B” “C” “D”
Packaged 100/ pack; 10 packs/case
34205 10R
0.84 0.5 0.605 0.665
34206 10Y
0.75 0.625 0.53 0.595
34207 12R
0.97 0.5 0.72 0.755
34208 12Y
0.86 0.625 0.655 0.715
34209 14R
1.125 0.5 0.85 0.905
34210 14Y
1.031 0.625 0.785 0.845
34211 16R
1.22 0.5 0.973 1.035
34212 16Y
1.125 0.625 0.893 0.963
34213 18R
1.33 0.562 1.093 1.155
34214 18Y
1.25 0.625 1.28 1.088
31215 19R
1.4 0.562 1.125 1.213
34229 4R
0.67 0.5 0.25 0.336
34230 5R
0.67 0.5 0.313 0.399
34231 6R
0.67 0.5 0.375 0.461
34232 8R
0.74 0.5 0.48 0.54
34233 8Y
0.67 0.625 0.413 0.483
34234 9R
0.75 0.5 0.5 0.586
Item No. Size “A” “B” “C” “D”
Packaged 50/pack; 10 packs/case
34216 20R
1.465 0.562 1.231 1.301
34217 20Y
1.406 0.625 1.15 1.215
34218 22R
1.59 0.562 1.34 1.41
34219 22Y
1.5 0.625 1.27 1.34
34220 24R
1.7 0.562 1.463 1.533
34221 24Y
1.64 0.625 1.39 1.46
34222 25Y
1.81 0.625 1.54 1.58
34223 28R
1.95 0.562 1.715 1.79
34224 28Y
1.875 0.625 1.645 1.718
Conductive C-Type Connector Cover Features:
Conductive Composite
Permanently volume conductive and free of carbon black particulate. The
connector covers do not leave black marks and are more suited to clean
situations. Meets the requirements of NASM5501 31/32.
Noncorrosive
Connector covers are noncorrosive and produce no visible corrosion when
tested to Federal Test Method 101C using Kovar test plates.
Conformability
The material used in the covers was selected for its resilience. Properly sized,
the covers provide a snug, secure fit. This helps keep connectors clean and
prevents the cover from accidentally falling off.
Specications and procedures subject to change without notice.
“It should be understood that any object, item, material or person could be a source of static electricity in the work
environment. Removal of unnecessary nonconductors, replacing nonconductive materials with dissipative or conductive
materials and grounding all conductors are the principle methods of controlling static electricity in the workplace,
regardless of the activity.” [ESD Handbook ESD TR20.20; section 2.4 Sources of Static Electricity]
Unless otherwise noted, tolerance ± 10%
Material Properties Test Method Typical Value
Resistance ASTM D991 <10
5
ohms
Contact Corrosivity
FTM 101C
Method 3005
(Kovar plate)
Pass
Elongation ASTM D638 24%
Tensile
ASTM D638
2700 psi
Vicat Softening
ASTM MD
1525
85° C
Outgassing ASTM E595 Pass
Item No. Size “A” “B” “C” “D”
Packaged 25/pack; 10 packs/case
34225 32R
2.22 0.562 1.965 2.04
34226 32Y
2.125 0.625 1.89 1.97
34227 36R
2.435 0.6 2.215 2.29
34228 36Y
2.34 0.625 2.14 2.21
ESD sensitive device
symbol
*ASTM F925

34222

Mfr. #:
Manufacturer:
Menda
Description:
Circular MIL Spec Tools, Hardware & Accessories Round Conductive Conn Cover 25Y
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet