LIGHTLINE
AC/DC-Converter
with 5 year Warranty
RACD20-D
20 Watt PFC
Single/Dual
Dimmable
● 20W Class II AC-DC LED Power Supply
● 2x Independent Constant Current Outputs
or Single High Current Output (Jumper selectable)
● 1-10V or Rheostat Dimmable (15%~100%)
● 3kVAC Isolation
● Active Power Factor Correction >0.95
● Fused Input, Protected Outputs
● CE Marked
● Long 5 Year Warranty
Features
LED
DRIVER
Selection Guide
Part Input Voltage Input Current Output Output Max
Number Range at full load Voltage Range Current #
(Nominal VAC) (mA) (VDC) (mA) LEDs
RACD20-350D 230VAC 260 2x (3-34) 2x (50~350) 2x (10 x 1W)
(700mA single output mode) 3-34 100~700 10 x 2W
RACD20-350D-US 110VAC 510 2x (3-34) 2x (50~350) 2x (10 x 1W)
(700mA single output mode) 3-34 100~700 10 x 2W
Input Voltage Range 230VAC 200-264VAC
110VAC 90-130VAC
Rated Power 20 Watts max.
Input Frequency Range 47-63 Hz
Power Factor Full Load, 115VAC/230VAC 0.95
Output Voltage Range 350mA Dual Output Mode 3-34VDC + 3-34VDC
700mA Single Output Mode 3-34VDC
Inrush Current (<2mS) 115VAC/230VAC 10A max.
Input Current 230VAC, Full Load 260mA typ.
Leakage Current 115VAC/240VAC - 60/50Hz 0.5mA typ.
Input Fuse 115VAC/230VAC T2A/T1A
Output Current Accuracy (combined Tolerance, load Regulation and Line Regulation) ±10%
Minimum Load Open Circuit Protected 1 LED
Output Ripple 150mA max.
Hold Up Time 18ms min.
Operating Frequency 40 - 100 kHz typ.
Efficiency at Full Load 230VAC >80%
RMS Isolation Voltage (input to output) 3kVAC / 1 minute
Temperature Coefficient ±0.02%/°C typ.
Overload Protection 120% typ.
Short Circuit Protection Continuous Current Limit
Dimming Control Rheostat (15%~100%) / 0-150kOhm / External Voltage (15%-100%) / 1-10VDC
Overtemperature Protection Shutdown, Automatic restart after cooling down
Operating Temperature Range Ambient Temperature -20°C to +40°C
(free air convection) Case Temp. +85°C max.
Weight 140g
continued on next page
Description
A compact 20W constant current switching power module suitable for driving either two independent strings of LEDs
or a single string high power LEDs (mode selction is via a jumper under the output cover plate). When used in dual
output mode, the two outputs are independently regulated and can be used with asymmetric LED loads. The output
current can be dimmed using either an external 150kOhm rheostat or via a 1-10V external voltage. Active power
factor correction is standard. Connections are via screw terminals and the AC input feature loop-through connections
to allow daisy chaining of the converters.
Specifications
(typical at 25°C and after warm up time unless otherwise specified )
EN 61347 Compliant
RoHS
2011/65/EU
6/6
Refer to Application Notes
www.recom-power.com L-31REV: 1/2015