TRMU158K002R0023

030617
97
TRM Professional Multianode
Tantalum Ultra Low ESR Capacitor
TEST
TRM professional multianode series (Temperature range -55ºC to +125ºC)
Condition Characteristics
Visual examination no visible damage
DCL initial limit
Endurance ΔC/C within ±10% of initial value
DF initial limit
ESR 1.25 x initial limit
Visual examination no visible damage
DCL 1.25 x initial limit
Storage Life 125ºC, 0V, 2000h ΔC/C within ±10% of initial value
DF initial limit
ESR 1.25 x initial limit
Visual examination no visible damage
DCL 1.5 x initial limit
Humidity ΔC/C within ±10% of initial value
DF 1.2 x initial limit
ESR 1.25 x initial limit
Visual examination no visible damage
Biased
DCL 2 x initial limit
Humidity
ΔC/C within ±10% of initial value
DF 1.2 x initial limit
ESR 1.25 x initial limit
+20ºC -55ºC +20ºC +85ºC +125ºC +20ºC
Temperature DCL
IL* n/a IL* 10 x IL* 12.5 x IL* IL*
Stability ΔC/C
n/a +0/-10% ±5% +10/-0% +12/-0% ±5%
DF
IL* 1.5 x IL* IL* 1.5 x IL* 2 x IL* IL*
ESR
1.25 x IL* 2.5 x IL* 1.25 x IL* 1.25 x IL* 1.25 x IL* 1.25 x IL*
Visual examination no visible damage
Surge
DCL initial limit
Voltage
ΔC/C within ±5% of initial value
DF initial limit
ESR 1.25 x initial limit
Visual examination no visible damage
DCL initial limit
MIL-STD-202, Method 213, Condition F ΔC/C within ±5% of initial value
DF initial limit
ESR 1.25 x initial limit
Visual examination no visible damage
DCL initial limit
MIL-STD-202, Method 204, Condition D ΔC/C within ±5% of initial value
DF initial limit
ESR 1.25 x initial limit
Determine after application of rated voltage for 2000
+48/-0 hours at 85±2ºC and then leaving 1-2 hours at
room temperature. Also determine of 125ºC tempera-
ture, category voltage for 2000 +48/-0 hours and
then leaving 1-2 hours at room temperature. Power
supply impedance to be ≤0.1Ω/V.
Determine after storage without applied voltage
at 65±2ºC and 95±2% relative humidity for 500
hours and then recovery 1-2 hours at room
temperature.
Determine after leaving for 1000 hours at 85±2ºC,
85% relative humidity and rated voltage and then
recovery 1-2 hours at room temperature.
Test temperature: 125ºC+3/0ºC
Test voltage: Category voltage at 125ºC
Surge voltage: 1.3 x category voltage at 125ºC
Series protection resistance 1000±100Ω
Discharge resistance: 1000Ω
Number of cycles: 1000x
Cycle duration: 6 min; 30 sec charge,
5 min 30 sec discharge
Step Temperature°C Duration(min)
1 +20±2 15
2 -55+0/-3 15
3 +20±2 15
4 +85+3/-0 15
5 +125+3/-0 15
6 +20±2 15
QUALIFICATION TABLE
*Initial Limit
Mechanical
Shock
Vibration

TRMU158K002R0023

Mfr. #:
Manufacturer:
N/A
Description:
CAP TANT 1500UF 10% 2.5V 2924
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union