EXB50-24S05

313
process
yellow
3405
1797
1375
116
2607
652
242
2985
375
240
Embedded Power for
Business-Critical Continuity
EXB50 Series
Single output
Special Features
High efciency topology, 91%
typical on EXB50-48S05J
Industry standard footprint
Wide operating temperature
-40 °C to +70 °C
(natural convection)
60% to 110% output trim
No minimum load
Overvoltage and
overtemperature protection
Remote sense compensation
Remote ON/OFF
Available RoHS compliant
2 year warranty
Total Power: 20-50W
Input Voltage: 36-75VDC
# of Outputs: Single
Safety
UL/cUL CAN/CSA 22.2
No. 60950-00 : UL 60950
File No. E174104
TÜV Product Service.
Certicate No.
B 03 08 38572 036
Rev.02.23.10_64
EXB50 Series
1 of 4
Electrical Specications
Output
Voltage adjustability:
60% to 110%
Setpoint accuracy:
± 1.5%
Line regulation:
Low line to high line 0.1% max.
Load regulation:
Full load to min. load 0.2% max.
Total error band:
± 3.0%
Minimum load:
0%
Overshoot:
At turn-on and turn-off None
Undershoot:
None
Ripple and noise:
(see Note 1)
5 Hz to 20 MHz 100 mV pk-pk
20 mV rms
Transient response:
(See Notes 2 and 8)
48 V models 2.0% peak deviation, 200 µs recovery
to within total error band
Remote sense:
(See Note 9) 10% o/p voltage change
All specications are typical at nominal input, full load at 25 °C unless otherwise stated.
Rev.02.23.10_64
EXB50 Series
2 of 4
Embedded Power for
Business-Critical Continuity
313
process
yellow
3405
1797
1375
116
2607
652
242
2985
375
240
Electrical Specications cont.
Input
Input voltage range:
(See Note 14)
48 V nominal
100 V 100 ms transient
36 - 75 Vdc
Input current:
48 V no load
48 V Remote OFF
60 mA max.
10 mA max.
Input current (max)
(See Note 4)
48 V models 1.7 A max. @ Io max. and Vin = 36 - 75 Vdc
Input reected ripple:
(See Note 6)
48 V models 50 mA (pk-pk) typ.
Remote ON/Off
Logic compatibility
ON
OFF
(See Note 15)
Open collector ref to -Input
Open circuit or > 2 Vdc
< 1.2 Vdc
Undervoltage lockout:
48 V Power up
48 V Power down
33.2 V max.
30.9 V min.
Start-up time:
(see Note 7)
Power up
Remote ON/OFF
30 ms
25 ms
EMC Characteristics
Conducted emissions:
EN55022 (See Note 3)
EN55022 (See Note 3)
Level A
Level B
Radiated emissions:
EN55022 Level A
Immunity:
(See Note 13)
ESD air:
EN61000-4-2 8 kV (NP), 15 kV (RP)
ESD contact:
EN61000-4-2 6 kV (NP), 8 kV (RP)
Radiated eld enclosure:
EN61000-4-3 10 V/m (NP)
Conducted (DC power):
EN61000-4-6 10 V/m (NP)
Conducted (signal)
EN61000-4-6 10 V/m (NP)
General Specications
Efciency:
See table
Basic insulation:
Input/output 1500 Vdc
Switching frequency:
Fixed 300 kHz typ.
Approvals & Standards:
(See Note 5) IEC60950/EN60950, UL/cUL1950, CSA C22.2 No. 950
Material ammability:
UL94V-0
Weight:
50 g (1.77 oz)
MTBF:
MIL-HDBK-217F @ 25 °C
100% load ground benign
270,000 hours
Environmental Specications
Thermal performance:
(See Notes 11, 12)
ETS 300 019-2-3
Operating ambient, temperature
(natural convection)
Non-operating
-40 °C to +70 °C
-55 °C to +125 °C
Classes T3.1 to T3.5
Altitude:
(See Note 10)
3,000 metres
10,000 metres
Derate max. output current by 20%
Derate max. output current by 50%
All specications are typical at nominal input, full load at 25 °C unless otherwise stated.
Rev.02.23.10_64
EXB50 Series
3 of 4
Embedded Power for
Business-Critical Continuity
313
process
yellow
3405
1797
1375
116
2607
652
242
2985
375
240
Notes
1 Measured as per recommended set-up. 150 mV pk-pk for EXB50-48S12J.
2 di/dt = 0.1 A/µs, Vin = 48 Vdc, Tc = 25 °C, load change = 0.5 lo max. to 0.75 lo
max. and 0.75 lo max. to 0.5 lo max.
3 The EXB50 meets level A and level B conducted emissions only with external
components connected before the input pins to the converter.
4 Recommended input fusing is 3.15 A HRC 200 V rated fuse on the 48 V.
5 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
6 Simulated source impedance of 12 µH. 12 µH inductor in series with +Vin.
7 Start-up into resistive load.
8 Maximum output deviation is 10% inclusive of trim.
9 Contact factory for operation at higher altitude.
10 See Application Note 113 for derating curves.
11 Input transient (48 V) ETS300 132-2 ETR283.
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
12 100 V, 100 ms transient applies to the EXB50-48S3V3J models. Please add
the sufx ‘R03’ to the model number e.g. EXB50-48S3V3R03J. This is also
active low remote ON/OFF.
13 Active low remote ON/OFF available. Please add sufx ‘-R’ to model number
e.g. EXB50-48S3V3-RJ.
14 The ‘J’ sufx indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special
request, please contact your local sales representative for details.
15 NOTICE: Some models do not support all options. Please contact your local
Emerson Network Power representative or use the on-line model number
search tool at http://www.PowerConversion.com to nd a suitable alternative.
Output can be externally trimmed by using the method shown below.
TRIM
UP
+ Sense
Trim
- Sense
TRIM
DOWN
RT1
or
RT2
External Output Trimming
Protection
Short-circuit Continuous
Overvoltage Non-latching clamp
Thermal 120 °C hot spot temperature with automatic recovery
Telecom Specication
Central ofce Interface A ETS300-132-2, Input voltage and current requirements
Ordering Information
Output
Power (Max.)
Input
Voltage
OVP Output
Voltage
Output Currents Efficiency
(Typ)
Regulation Model Numbers
(16,17)
(Min) (Max) Line Load
18 W 36 - 75 Vdc 2.15 Vdc 1.8 V 0 A 10 A 85.7% ± 0.1% ± 0.2%
EXB50-48S1V8J
(15)
20 W 36 - 75 Vdc 2.45 Vdc 2 V 0 A 10 A 87.5% ± 0.1% ± 0.2%
EXB50-48S2V0J
(15)
25 W 36 - 75 Vdc 2.95 Vdc 2.5 V 0 A 10 A 87.5% ± 0.1% ± 0.2%
EXB50-48S2V5J
(15)
33 W 36 - 75 Vdc 4 Vdc 3.3 V 0 A 10 A 90.0% ± 0.1% ± 0.2%
EXB50-48S3V3J
(14, 15)
50 W 36 - 75 Vdc 6.15 Vdc 5 V 0 A 10 A 91.0% ± 0.1% ± 0.2%
EXB50-48S05J
(15)
50 W 36 - 75 Vdc 14.2 Vdc 12 V 0 A 4.2 A 90.0% ± 0.1% ± 0.2%
EXB50-48S12J
(15)

EXB50-24S05

Mfr. #:
Manufacturer:
Description:
DC DC CONVERTER 5V 50W
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS