MBA0204AC2709FC100

MBA/SMA 0204 HF
www.vishay.com
Vishay Beyschlag
Revision: 27-Mar-13
4
Document Number: 28769
For technical questions, contact: filmresistorsleaded@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Rise of the Surface Temperature
Temperature Rise
RF - Behaviour
°C
100 150
0
- 50 0 5 0
0. 5
1
W
70
Ambient Temperature
amb
ϑ
Power Dissipation
P
MBA/SMA 0204 HF
0.80.6 0.7
0
0 0.4 W
40
K
60
0.2
20
0.1 0.3 0.5
80
Load
P
Temperature Rise
T
r
MBA/SMA 0204 HF
|Z|/R for MBA/SMA 0204 HF
.,
470 Ω
220 Ω
100 Ω
50 Ω
27 Ω
6.8 Ω
0.5
Frequency
f
IZI/R
0.1 0.3 10 20
GHz
1.0
1.5
2.0
1
MBA/SMA 0204 HF
www.vishay.com
Vishay Beyschlag
Revision: 27-Mar-13
5
Document Number: 28769
For technical questions, contact: filmresistorsleaded@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
TESTS AND REQUIREMENTS
Essentially all tests are carried out in accordance with the
following specifications:
EN 60115-1, generic specification (includes tests)
EN 140100, sectional specification (includes schedule for
qualification approval)
CECC 40101-806, detail specification (includes schedule
for conformance inspection)
The following table contains the applicable tests selected
from the documents listed above.
The tests are carried out in accordance with IEC 60068-xx
test method and under standard atmospheric conditions in
accordance with IEC 60068-1, 5.3. Climatic category
LCT/UCT/56 (rated temperature range: Lower Category
Temperature, Upper Category Temperature; damp heat,
long term, 56 days) is valid.
Unless otherwise specified the following values apply:
Temperature: 15 °C to 35 °C
Relative humidity: 45 % to 75 %
Air pressure: 86 kPa to 106 kPa (860 mbar to 1060 mbar).
For testing the components are mounted on a test board in
accordance with IEC 60115-1, 4.31 unless otherwise
specified.
In the Test Procedures and Requirements table only the
tests and requirements are listed with reference to the
relevant clauses of IEC 60115-1 and IEC 60068-2 test
methods. A short description of the test procedure is also
given.
TEST PROCEDURES AND REQUIREMENTS
IEC
60115-1
CLAUSE
IEC
60 068-2-xx
TEST
METHOD
TEST PROCEDURE
REQUIREMENTS
PERMISSIBLE CHANGE
(R MAX.)
Stability for product types:
MBA/SMA 0204 HF 1.5 to 470
4.5 - Resistance ± 1 %; ± 2 %
4.8 - Temperature coefficient
At (20 / LCT / 20) °C and
(20 / UCT / 20) °C
± 50 ppm/K
4.25.1
-
Endurance at
70 °C: standard
operation mode
U = or U = U
max.
;
1.5 h ON; 0,5 h OFF
70 °C; 1000 h ± (0.5 % R+0.05 )
70 °C; 8000 h ± (1 % R+0.1 )
-
Endurance at
70°C: long term
operation mode
U = or U = U
max.
;
1.5 h ON; 0,5 h OFF
70 °C; 1000 h ± (0.25 % R+0.05 )
70 °C; 8000 h ± (0.5 % R+0.05 )
4.25.3 -
Endurance at upper
category temperature
125°C; 1000 h ± (0.25 % R+0.05 ))
155 °C; 1000 h ± (0.5 % R+0.05 )
4.24 78 (Cab)
Damp heat,
steady state
(40 ± 2)°C; 56days;
(93 ± 3) %RH
± (0.5 % R+0.05 )
4.23 Climatic sequence:
4.23.2 2 (Ba) Dry heat 155 °C; 16h
4.23.3 30 (Db) Damp heat, cyclic
55 °C; 24h; 90% to100%RH;
1 cycle
4.23.4 1 (Aa) Cold -55 °C; 2h
4.23.5 13 (M) Low air pressure 8.5kPa; 2h; 15 °Cto35 °C
4.23.6 30 (Db) Damp heat, cyclic
55 °C; 5days;
95 % to 100 % RH; 5 cycles
± (0.5 % R+0.05 )
no visible damage
- 1 (Aa) Cold -55 °C; 2 h ± (0.1 % R+0.01 )
4.13 - Short time overload
Room temperature;
U = 2.5 x or
U
= 2 x U
max.
; 5 s
± (0.1 % R+0.01 )
no visible damage
4.19 14 (Na)
Rapid change of
temperature
30 min at LCT and
30 min at UCT; 5 cycles
± (0.1 % R+0.01 )
no visible damage
P
70
x R
P
70
x R
P
70
x R
MBA/SMA 0204 HF
www.vishay.com
Vishay Beyschlag
Revision: 27-Mar-13
6
Document Number: 28769
For technical questions, contact: filmresistorsleaded@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
12NC INFORMATION FOR HISTORICAL CODING REFERENCE
Last Digit of 12NC Indicating Resistance Decade Ordering Example (For historical coding reference of
MBA 0204 HF)
The ordering code of a MBA 0204 HF resistor, value 51
and TCR 50 with ± 2 % tolerance, supplied on bandolier
ammopack, in a box units is: 2312 908 05109.
4.29 45 (XA)
Component solvent
resistance
Isopropyl alcohol +23 °C;
toothbrush method
marking legible;
no visible damage
4.18.2 20 (Tb)
Resistance to soldering
heat
Unmounted components;
(260 ± 3) °C; (10 ± 1) s
± (0.1 % R+0.01 )
no visible damage
4.17 20 (Ta) Solderability
+235 °C; 2 s
solder bath method;
SnPb40
Good tinning (95 % R covered);
no visible damage
+ 245 °C; 3 s
solder bath method;
SnAg3Cu0.5
4.22 6 (B4) Vibration
6 h; 10 Hz to 2000 Hz 1.5 mm
or 196 m/s
2
± (0.1 % R+0.01 )
4.16
21 (Ua
1
)
21 (Ub)
21 (Uc)
Robustness of terminations Tensile, bending and torsion
± (0.1 % R+0.01 )
no visible damage
4.7 - Voltage proof U
RMS
= U
ins
; 60 s No flashover or breakdown
TEST PROCEDURES AND REQUIREMENTS
IEC
60115-1
CLAUSE
IEC
60 068-2-xx
TEST
METHOD
TEST PROCEDURE
REQUIREMENTS
PERMISSIBLE CHANGE
(R MAX.)
Stability for product types:
MBA/SMA 0204 HF 1.5 to 470
RESISTANCE DECADE LAST DIGIT
1 to 9.99 8
10 to 99.9 9
100 to 999 1
12NC CODE FOR HISTORICAL CODING REFERENCE OF MBA 0204 HF
DESCRIPTION
2312 ... .....
BANDOLIER IN BOX
AMMOPACK
TYPE TCR TOL.
C1
1000
UNITS
CT
5000
UNITS
MBA 0204 HF ± 50 ppm/K ± 2 % 903 0.... 908 0....

MBA0204AC2709FC100

Mfr. #:
Manufacturer:
Description:
Thin Film Resistors - Through Hole MBA/SMA 0204-50 1% HF C1 27R