74LVC06A
www.onsemi.com
3
RECOMMENDED OPERATING CONDITIONS
Symbol Parameter Min Typ Max Unit
V
CC
Supply Voltage Operating
Functional
1.65
1.2
5.5
5.5
V
V
I
Input Voltage 0 5.5 V
V
O
Output Voltage Active Mode
3−State
0
0
V
CC
5.5
V
I
OL
LOW Level Output Current V
CC
= 4.5 V − 5.5 V
V
CC
= 3.0 V − 3.6 V
V
CC
= 2.7 V − 3.0 V
V
CC
= 2.3 V − 2.7 V
+32
+24
+12
+8
mA
T
A
Operating Free−Air Temperature −40 +125 °C
Dt/DV
Input Transition Rise or Fall Rate V
CC
= 1.65 to 2.7 V
V
CC
= 2.7 to 5.5 V
0
0
20
10
ns/V
Functional operation above the stresses listed in the Recommended Operating Ranges is not implied. Extended exposure to stresses beyond
the Recommended Operating Ranges limits may affect device reliability.
DC ELECTRICAL CHARACTERISTICS
Symbol Parameter Conditions
−40 to +855C −40 to +1255C
Unit
Min
Typ
(Note 4)
Max Min
Typ
(Note 4)
Max
V
IH
HIGH−level input voltage
V
CC
= 1.2 V 1.08 − − 1.08 − −
V
V
CC
= 1.65 V to 1.95 V 0.65 x
V
CC
− − 0.65 x
V
CC
− −
V
CC
= 2.3 V to 2.7 V 1.7 − − 1.7 − −
V
CC
= 2.7 V to 3.6 V 2.0 − − 2.0 − −
V
CC
= 4.5 V to 5.5 V 0.7 x
V
CC
− − 0.7 x
V
CC
− −
V
IL
LOW−level input voltage
V
CC
= 1.2 V − − 0.12 − − 0.12
V
V
CC
= 1.65 V to 1.95 V − − 0.35 x
V
CC
− − 0.35 x
V
CC
V
CC
= 2.3 V to 2.7 V − − 0.7 − − 0.7
V
CC
= 2.7 V to 3.6 V − − 0.8 − − 0.8
V
CC
= 4.5 V to 5.5 V − − 0.3 x
V
CC
− − 0.3 x
V
CC
V
OL
LOW−level output voltage
V
I
= V
IH
or V
IL
− − −
V
I
O
= 100 mA;
V
CC
= 1.65 V to 3.6 V
− − 0.2 − − 0.3
I
O
= 4 mA; V
CC
= 1.65 V − − 0.45 − − 0.65
I
O
= 8 mA; V
CC
= 2.3 V − − 0.6 − − 0.8
I
O
= 12 mA; V
CC
= 2.7 V − − 0.4 − − 0.6
I
O
= 24 mA; V
CC
= 3.0 V − − 0.55 − − 0.8
I
O
= 32 mA; V
CC
= 4.5 V − − 0.55 − − 0.8
I
I
Input leakage current V
I
= 5.5 V or GND
V
CC
= 1.65 to 5.5 V
− ±0.1 ±5 − ±0.1 ±20
mA
I
OZ
OFF−state output current V
I
= V
IH
; V
O
= 5.5 V or GND;
V
CC
= 1.65 to 5.5 V
− ±0.1 ±5 − ±0.1 ±20
mA
I
OFF
Power−off leakage current V
I
or V
O
= 5.5 V; V
CC
= 0 V − ±0.1 ±10 − ±0.1 ±20
mA
4. All typical values are measured at T
A
= 25°C and V
CC
= 3.3 V, unless stated otherwise.