ADuM1280/ADuM1281/ADuM1285/ADuM1286 Data Sheet
Rev. D | Page 10 of 18
ABSOLUTE MAXIMUM RATINGS
T
A
= 25°C, unless otherwise noted.
Table 18.
Parameter Rating
Storage Temperature (T
ST
) Range −65°C to +150°C
Ambient Operating Temperature
(T
A
) Range
−40°C to +125°C
Supply Voltages (V
DD1
, V
DD2
) −0.5 V to +7.0 V
Input Voltages (V
IA
, V
IB
) −0.5 V to V
DDI
+ 0.5 V
Output Voltages (V
OA
, V
OB
) −0.5 V to V
DD2
+ 0.5 V
Average Output Current per Pin
1
Side 1 (I
O1
) −10 mA to +10 mA
Side 2 (I
O2
) −10 mA to +10 mA
Common-Mode Transients
2
−100 kV/μs to +100 kV/μs
1
See Figure 3 for maximum rated current values for various temperatures.
2
Refers to common-mode transients across the insulation barrier. Common-mode
transients exceeding the absolute maximum ratings may cause
latch-up or permanent damage.
Stresses at or above those listed under Absolute Maximum Ratings
may cause permanent damage to the product. This is a stress rating
only; functional operation of the product at these or any other
conditions above those indicated in the operational section of this
specification is not implied. Operation beyond the maximum
operating conditions for extended periods may affect product
reliability.
ESD CAUTION
Table 19. Maximum Continuous Working Voltage
1
Parameter Max Unit Constraint
AC Voltage, Bipolar Waveform 565 V peak 50-year minimum lifetime
AC Voltage, Unipolar Waveform
Basic Insulation 1131 V peak Maximum approved working voltage per IEC 60950-1
Reinforced Insulation 560 V peak Maximum approved working voltage per IEC 60950-1 and VDE V 0884-10
DC Voltage
Basic Insulation 1131 V peak Maximum approved working voltage per IEC 60950-1
Reinforced Insulation 560 V peak Maximum approved working voltage per IEC 60950-1 and VDE V 0884-10
1
Refers to continuous voltage magnitude imposed across the isolation barrier. See the Insulation Lifetime section for more details.