B58623K0510A016

Pressure sensors
Pressure transmitters without casing (voltage output) CAU-T series
AS SEN PD 2009-08-03
Please read Cautions and warnings and Page 4 of 8
Important notes at the end of this document.
Characteristics
Simple output (AUA, AUR)
Symmetrical output (AUS)
Connection diagram
Electrical connection (view to soldering side)
V
A0
-p
r
+p
r
0
V
A0
+ ½V
V
A0
- ½V
FS
0 p
r
V
A0
+ V
FS
V
A0
p
V
A
U
V
cc
GND
Pressure sensors
Pressure transmitters without casing (voltage output) CAU-T series
AS SEN PD 2009-08-03
Please read Cautions and warnings and Page 5 of 8
Important notes at the end of this document.
Rated pressures and ordering codes
Pressure
measurement
Absolute Gauge
Gauge, symmetrical
Rated pressure p
r
bar
1.000
2.500
6.000
10.00
25.00
0.100
0.250
0.400
1.000
2.500
6.000
10.00
25.00
0.100
0.250
0.400
1.000
Product type
AUA 1.000 TH V4 TN L P
AUA 2.500 TH V4 TN L P
AUA 6.000 TH V4 TN L P
AUA 10.00 TH V4 TN L P
AUA 25.00 TH V4 TN L P
AUR 0.100 KC V4 TN L P
AUR 0.250 KC V4 TN L P
AUR 0.400 KC V4 TN L P
AUR 1.000 KC V4 TN L P
AUR 2.500 KC V4 TN L P
AUR 6.000 KC V4 TN L P
AUR 10.00 KC V4 TN L P
AUR 25.00 KC V4 TN L P
AUS 0.100 KC V4 TN L P
AUS 0.250 KC V4 TN L P
AUS 0.400 KC V4 TN L P
AUS 1.000 KC V4 TN L P
Ordering code
B58620T0510A001
B58620T0510A002
B58620T0510A003
B58620T0510A004
B58620T0510A005
B58621K0510A006
B58621K0510A007
B58621K0510A008
B58621K0510A009
B58621K0510A010
B58621K0510A011
B58621K0510A012
B58621K0510A013
B58623K0510A014
B58623K0510A015
B58623K0510A016
B58623K0510A017
Other rated pressures upon request.
Pressure sensors
Pressure transmitters without casing (voltage output) CAU-T series
AS SEN PD 2009-08-03
Please read Cautions and warnings and Page 6 of 8
Important notes at the end of this document.
Symbols and terms
1)
Storage temperature range T
st
A storage of the pressure sensor within the temperature range T
st,min
up to T
st,max
and without applied pressure and supply voltage will not affect the performance of the pressure sensor.
2)
Operating temperature range T
a
An operation of the pressure sensor within the temperature range T
a,min
up to T
a,max
will not affect the performance of the pressure sensor.
3)
Compensated temperature range T
c
While operating the pressure sensor within the temperature range T
c,min
up to T
c,max
,
the deviation of the output signal from the values at 25 °C will not exceed the temperature coefficients.
Out of the compensated temperature range, the deviations may increase.
4)
Rated pressure p
r
Within the rated pressure range 0 up to p
r
(symmetrical output: –p
r
up to +p
r
) the signal output characteristic corresponds
to this specification.
5)
Overpressure p
OV
Pressure cycles within the pressure range 0 up to p
ov
will not affect the performance of the pressure sensor.
6)
Supply voltage V
CC
V
CC,max
is the maximum permissible supply voltage, which can be applied without damages.
V
CC,min
is the minimum required supply voltage, which has to be applied for normal operation.
7)
Signal output current I
A
I
A,max
is the maximum permissible sink current of the signal output.
Exceeding (e.g. short circuit) may cause irreparable damages.
8)
DC break down voltage V
is
The pressure sensor withstands a high voltage between the stainless steel pressure connection and the electrical
connection V
CC
, V
A
and GND (all short circuited) without damage.
9)
Offset V
A0
The offset V
A0
is the signal output V
A
(p = 0) at zero pressure.
10)
Signal span (Full Scale)
Simple output: V
FS
= FS = V
A
(p
r
) – V
A0
Symmetrical output: V
FS
= FS = V
A
(+p
r
) – V
A
(–p
r
)
11)
Nonlinearity L (including pressure hysteresis)
The nonlinearity is the deviation of the real sensor characteristic V
A
= f(p) from the ideal straight line.
It can be approximated by a polynomial of second order, with the maximum at p
x
= p
r
/ 2 .
The equation to calculate the nonlinearity is:
r
x
0ArA
0AxA
p
p
V)p(V
V)p(V
L
=
12)
Response time t
10-90
Delay between a pressure change (10 ... 90% p
r
) and the corresponding signal output change (10 ... 90% FS).
13)
Supply voltage rejection SVR
While varying the supply voltage within the range V
CC,min
up to V
CC,max
at constant pressure and temperature,
the signal output change will not exceed SVR
max
.
14)
Temperature hysteresis
The temperature hysteresis is the change of offset, starting from the value at 25 °C after a temperature change
and return to 25 °C. Determined during temperature cycles in operating temperature range (cycles with 1 K/min).
15)
Temperature coefficient of offset TCV
A0
Offset at temperature T
x
: V
A0
(T
x
) = V
A0
(25 °C) + V
FS
(25 °C) · (T
x
– 25 °C) · TCV
A0
Values are valid within the compensated temperature range T
c,min
up to T
c,max
Out of the compensated temperature range, the deviation may increase.
16)
Temperature coefficient of span TCV
FS
Span at temperature T
x
: V
FS
(T
x
) = V
FS
(25 °C) · [ 1 + (T
x
– 25 °C) · TCV
FS
]
Values are valid within the compensated temperature range T
c,min
up to T
c,max
Out of the compensated temperature range, the deviation may increase.

B58623K0510A016

Mfr. #:
Manufacturer:
EPCOS / TDK
Description:
Board Mount Pressure Sensors PRESSURE SENSOR AUS 0.400 KC V4 TN LP
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: